Removal And Replacement; Required Tools; Preparing For Removal; Performing The Removal - Bosch rexroth A15VO Instruction Manual

Axial piston variable pump
Hide thumbs Also See for rexroth A15VO:
Table of Contents

Advertisement

50/60
A15VO/A15VLO series 12 | Removal and replacement
Bosch Rexroth AG, RE 92512-01-B/2023-03-27

11 Removal and replacement

11�1 Required tools
Removal can be performed using standard tools. No special tools are necessary.
11�2 Preparing for removal
1� Decommission the relevant system part as described in the instruction
manual for the machine or system.
– Relieve pressure in the hydraulic system according to the instructions
of the machine or system manufacturer.
– Make sure the relevant machine/system components are depressurized and
de-energized.
2� Secure the relevant system part against reactivation.
11�3 Performing the removal
Proceed as follows to remove the axial piston unit:
1� Make sure you have the appropriate tools and wear personal protective
equipment.
2� Allow the axial piston unit to cool down until it can be removed without danger.
3� For below-reservoir installation, before removing the axial piston unit,
seal the connection to the reservoir and/or drain the reservoir.
4� Place a drip tray under the axial piston unit to collect any hydraulic fluid that
may leak.
5� Disconnect the lines and collect the escaping hydraulic fluid in the drip tray.
6� Remove the axial piston unit. Use a suitable lifting device.
7� Completely drain the axial piston unit.
8� Plug all openings.
11�4 Preparing the components for storage or further use
▶ Proceed as described in chapter 6.2 "Storing the axial piston unit"
on page 24.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth 12 seriesRexroth a15vlo

Table of Contents