Installation Position 1; Below-Reservoir Installation (Standard) - Bosch rexroth 12 Series Instruction Manual

Axial piston variable pump
Hide thumbs Also See for rexroth 12 Series:
Table of Contents

Advertisement

28/60
A15VSO/A15VLO series 12 | Installation

Installation position 1

Air bleed
Filling
T
(F)
S + T
1
1
F
SB
h
t min
h
min
T
1
T
3
S
T
2
Bosch Rexroth AG, RE 92802-01-B/2023-03-27
▶ Use fiber-free cleaning cloths for cleaning.
▶ Use suitable, mild cleaning agents to remove lubricants and other heavy
contamination. Do not allow cleaning agents to enter into the hydraulic system.
7�3 Installation position
The following installation positions are permissible. The pipeline routing shown
illustrates the basic layout.
Recommended installation position: 1 and 2.
Port F is part of the external piping and must be provided on the customer side
to make filling and air bleeding easier.
Key
T
, T
, T
Drain port
1
2
3
F
Filling/air bleeding
S
Suction port
SB
Mixer wall (baffle plate)
h
Minimum required immersion depth (200 mm)
t min
h
Minimum required distance to reservoir bottom (100 mm)
min
h
Minimum height required to prevent axial piston unit from
ES min
draining (25 mm)
h
Maximum permissible suction height (800 mm)
S max
7�3�1 Below-reservoir installation (standard)
Below-reservoir installation means that the axial piston unit is installed outside
of the reservoir below the minimum fluid level.
Installation position 2
Air bleed
Filling
T
(F)
S + T
2
F
h
t min
h
min
T
S
2
T
1
Installation position 3
Air bleed
T
(F)
2
2
SB
T
1
T
3
Filling
S + T
2
F
SB
h
t min
h
min
T
2
S
T
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth a15vsoRexroth a15vlo

Table of Contents