Installation Position; Below-Reservoir Installation (Standard) - Bosch rexroth 11 Series Instruction Manual

Axial piston variable pump
Table of Contents

Advertisement

1
F
h
t min
h
min
T
1
T
S
2
Fig. 9: Below-reservoir installation A15VO/A15VLO with installation position 1–3

7.3 Installation position

The axial piston unit can be installed in the following positions. The pipeline routing
shown illustrates the basic layout.

7.3.1 Below-reservoir installation (standard)

Below-reservoir installation means that the axial piston unit is installed outside of
the reservoir below the minimum fluid level.
Recommended installation position: 1 and 2.
2
SB
F
T
2
T
3
T
Drain port
T
, T
, T
1
2
3
Filling/air bleeding
F
S
Suction port
Port F is part of the external piping and must be provided on the customer side
to make filling and air bleeding easier.
Table 9: Below-reservoir installation
Installation position
1 (drive shaft horizontal)
2 (drive shaft horizontal)
3 (drive shaft vertically up)
SB
h
t min
h
min
S
T
3
1
SB
h
t min
h
min
Air bleed
T
+ F
1
+ F
T
2
+ F
T
2
RE 92511-01-B/2019-10-09, A15V(L)O Series 11, Bosch Rexroth AG
Installation
3
F
SB
h
t min
h
min
T
1
T
2
S
T
3
Baffle (baffle plate)
Minimum required immersion depth
(200 mm)
Minimum required distance to
reservoir bottom (100 mm)
Filling
S + T
1
S + T
2
S + T
2
29/64

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth a15voRexroth a15vlo

Table of Contents