Storing The Axial Piston Unit - Bosch rexroth 12 Series Instruction Manual

Axial piston variable pump
Hide thumbs Also See for rexroth 12 Series:
Table of Contents

Advertisement

24/60
A15VSO/A15VLO series 12 | Transport and storage
Requirement
After delivery
Bosch Rexroth AG, RE 92802-01-B/2023-03-27
▶ Place the lifting strap around the axial piston unit in such a way that it does not
pass over assembled parts (e.g. valves, piping) and that the axial piston unit is
not suspended from assembled parts (see Fig. 6).
Fig� 6: Transport with lifting strap
6�2 Storing the axial piston unit
• Storage areas should be free of corrosive materials and gases.
• To prevent damage to the seals, do not operate ozone-forming equipment
(e.g. mercury-vapor lamps, high-voltage equipment, electric motors,
sources of electrical sparks or electrical discharge) in storage areas.
• Storage areas should be dry.
Recommended relative humidity ≤ 60%.
• Ideal bearing temperature: +5 °C to +20 °C.
• Minimum storage temperature: −50 °C.
• Maximum storage temperature: +60 °C.
• Keep out of direct sunlight.
• Do not stack axial piston units and store them in a shock-proof manner.
• Do not store the axial piston unit on the drive shaft or assembled parts,
e.g. sensors or valves.
• For further storage conditions, see Table 8.
▶ Check the axial piston unit monthly to ensure professional storage.
The axial piston units come in corrosion protection packaging (corrosion protection
film) provided at the factory.
Table 8 lists the maximum permissible storage times for an unpackaged axial piston
unit as per data sheet 90312.
Table 8: Storage time with factory-supplied corrosion protection
Storage conditions
Closed, dry room,
uniform temperature
between +5 °C and +20 °C.
Undamaged and closed
corrosion protection film.
Standard corrosion
Long-term corrosion
protection
protection (optional)
Maximum 12 months
Maximum 24 months

Advertisement