Haier AB36NACBEA Service Manual page 40

4hp 5hp universal outdoor unit air conditioning
Hide thumbs Also See for AB36NACBEA:
Table of Contents

Advertisement

Fig. 28
A. Solid wire
Loop
Insulation
HOW TO FIXED CONNECTION CORD AND POWER CABLE AT THE CORD CLAMP
After passing the connection cord and power cable through the insulation tube, fasten it with the cord clamp, as shown in Fig.29
Fig. 29
ELECTRICAL REQUIREMENT
Electric wire size and fuse capacity:
Table 5
Series
Connection
MAX
cord
MIN
(mm
)
2
Fuse capacity(A)
ELECTRICAL WIRING
CAUTION
(1) Match the terminal block numbers and connection
cord colors with those of the outdoor unit.
Erroneous wiring may cause burning of the electric
parts.
(2) Connect the connection cords firmly to the terminal
block. Imperfect installation may cause a fire.
(3) Always fasten the outside covering of the connection
cord with the cord clamp.(If the insulator is chafed,
electric leakage may occur.)
(4) Always connect the ground wire.
1. INDOOR UNIT SIDE
(1) Remove the electric component box.
B. Strand wire
Round
terminal
Insulation tube
Use VW-1, 0.5 to 1.0 mm thick, PVC tube as the insulation tube.
42
36
3.5
3.5
2.5
2.5
30
30
INSTALLATION INSTRUCTIONS
Screw with
special washer
Round
terminal
Terminal
board
Wire
Wire
Cord clamp
Fig. 30
INDOOR UNIT SIDE
Fig. 31
Electric component box
Remove the four tapping
screws.
Screw with
special washer
Round
terminal
Electric component box
CAUTION
Do not remove the screws. If the screws
are removed, the electric component
box will fall.