10.2 Inspection
Bosch Rexroth recommends documenting the inspection results so that
• considering functionality and economy, the inspection and maintenance intervals
can be adjusted to the actual operating conditions.
• by comparing the documented values, you can identify faults at an early point in
time.
▶
Before any inspection work, clean the hydraulic power unit as necessary.
▶
Carry out the following visual inspections for clearly apparent defects:
– Illegible notices or warning signs
– Leakage
– Loose and/or missing parts
▶
Indications of external force effects
10.3 Warning devices
The hydraulic power unit is equipped with an LED strip for status display:
• Normal operation: LED strip illuminated in cyan
• Warning:
LED strip illuminated in yellow
• Error:
LED strip illuminated in red
Precise reading of error messages is possible via the X26 interface
(engineering port) of the control section and the IndraWorks DS software.
The errors are also indicated on the display of the drive controller, see Fig. 7,
pos. 16 on page 50.
Maintenance and repair 99/128
CytroBox, RE 51057-B/11.19, Bosch Rexroth AG