Bosch rexroth CytroBox Operating Instructions Manual page 33

Hydraulic power unit
Table of Contents

Advertisement

Oil level
Oil temperature
Particle concentration
The oil level monitoring is always active because the I/O link sensor is available as a
standard. The monitoring is based on a cycle time of 200 ms.
Table 16: Oil level monitoring
Message
Threshold value
Warning too low
P-0-1389[71]
Error too low
P-0-1389[73]
Warning too high
P-0-1389[72]
Error too high
P-0-1389[74]
The oil temperature monitoring is always active because the I/O link sensor is
available as a standard. The monitoring is based on a cycle time of 200 ms.
Table 17: Oil temperature monitoring
Message
Threshold value
[°C]
Warning too low
P-0-1389[25]
Error too low
P-0-1389[27]
Warning too high
P-0-1389[26]
Error too high
P-0-1389[28]
The monitoring of the particle concentration is active if a measured value via
an I/O link sensor is present. The sensor serially reads in the particle concentration
for different particle sizes as ordinal number. The monitoring interval is therefore
specified by the sensor and is 21 s in the default configuration.
Table 18: Particle concentration monitoring
Message
Threshold value
Warning S - 4 µm
P-0-1389[61]
Error S - 4 µm
P-0-1389[65]
Warning M - 6 µm
P-0-1389[62]
Error M - 6 µm
P-0-1389[66]
Warning L - 14 µm
P-0-1389[63]
Error L - 14 µm
P-0-1389[67]
Warning XL - 21 µm
P-0-1389[64]
Error XL - 21 µm
P-0-1389[68]
Debouncing
[l]
time [ms]
P-0-1389[75]
Debouncing
time [ms]
P-0-1389[24]
Debouncing
[OZ]
time [ms]
-
CytroBox, RE 51057-B/11.19, Bosch Rexroth AG
Product information 33/128
Diagnostic
Bit in status word
number
(P-0-1412/P-0-1413)
B301
1
D301
B300
0
D300
Diagnostic
Bit in status word
number
(P-0-1412/P-0-1413)
B308
8
D308
B307
7
D307
Diagnostic
Bit in status word
number
(P-0-1412/P-0-1413)
B302
2
D302
B303
3
D303
B304
4
D304
B305
5
D305