Bosch rexroth CytroBox Operating Instructions Manual page 16

Hydraulic power unit
Table of Contents

Advertisement

16/128 Safety instructions
Bosch Rexroth AG, CytroBox, RE 51057-B/11.19
Hydraulic power unit has hot surfaces (motor, pump, block, valves, electronic
components)!
Risk of injury! Risk of burning!
Allow the hydraulic power unit to cool down sufficiently before touching it.
Wear heat-resistant gloves or protective clothing. During or after the operation,
temperatures may rise to values higher than 60 °C, depending on the operating
conditions.
Observe the protective measures of the machine/system manufacturer and/or
operator.
Make sure that during operation, all doors are closed.
Leaked hydraulic fluid, oily surfaces!
Risk of injury! Slip hazard!
If no separate hydraulic room is available, put the hydraulic power unit into a
drip pan.
Protect and mark the danger zone.
Immediately remove hydraulic fluid that has leaked out.
Use an oil binding agent in order to bind the leaked hydraulic fluid.
Remove and dispose of the contaminated oil binding agent, see chapter 13
"Disposal".
Wear the personal protective equipment prescribed for your activity.
Perform a leak test.
Contact with hydraulic fluid!
Health hazard/impairment of health, e.g. eye injuries, skin lesions, intoxication
upon inhalation or due to swallowing, sensitization!
Avoid contact with hydraulic fluids.
When dealing with hydraulic fluids, you must imperatively observe the
safety instructions of the hydraulic fluid manufacturer.
Use your personal protective equipment (like e.g. safety goggles,
protective gloves, suitable working clothes, safety shoes).
If nevertheless hydraulic fluid comes into contact with the eyes or gets into the
bloodstream or is swallowed, please consult a doctor immediately.
Electro-magnetic/magnetic fields!
Health hazard for persons with cardiac pacemakers, metal implants or hearing aids!
Make sure that above specified personnel are prevented from accessing areas
where drive components are installed and operated or arrange consultation with
a doctor for approval.
Loud noise due to high sound pressure level (in case of malfunction)!
Danger of hearing damage (temporary/permanent), stress/loss of attention!
Fault in voice communication and acoustic signals!
Wear your ear protection.
Consult the machine manufacturer or Bosch Rexroth to identify any malfunction
if applicable.
Make sure that during operation, all doors are closed.
CAUTION

Advertisement

Table of Contents
loading

Table of Contents