46/128 Product information
S-0-0390
P-0-1300
S-0-0095
F2013
D300
D300: oil level of
tank too high
F2013
D301
D301: oil level of tank
too low
F2013
D302
D302: particle
content S too high
F2013
D303
D303: particle
content M too high
F2013
D304
D304: particle
content L too high
F2013
D305
D305: particle
content XL too high
F2013
D306
D306: filter clogging
too high
F2013
D307
D307: oil
temperature too high
F2013
D308
D308: oil
temperature too low
F2013
D309
D309: oxygen
content too high
F2013
D310
D310: relative
humidity too high
F2013
D318
D318: leakage very
high
Bosch Rexroth AG, CytroBox, RE 51057-B/11.19
Table 38: Error
Cause
The monitoring of the oil level
indicates an alarm.
P-0-1291 > P-0-1389[74]
The monitoring of the oil level
indicates an alarm.
P-0-1291 < P-0-1389[73]
The monitoring of the particle
concentration indicates an
alarm.
P-0-1424 > P-0-1389[65]
The monitoring of the particle
concentration indicates an
alarm.
P-0-1425 > P-0-1389[66]
The monitoring of the particle
concentration indicates an
alarm.
P-0-1426 > P-0-1389[67]
The monitoring of the particle
concentration indicates an
alarm.
P-0-1427 > P-0-1389[68]
The monitoring of the filter
contamination indicates an
alarm.
(P-0-1273 – S-0-0813)
> P-0-1389[31]
The monitoring of the oil
temperature indicates an alarm.
P-0-1280 > P-0-1389[28]
The monitoring of the oil
temperature indicates an alarm.
P-0-1280 < P-0-1389[27]
The monitoring of the air
inclusion indicates an alarm.
P-0-1270 > P-0-1389[8]
The monitoring of the relative
humidity indicates an alarm.
P-0-1272 > P-0-1389[14]
The monitoring of the leakage
flow indicates an alarm.
P-0-1293 > P-0-1389[40]
Remedy
Check/reduce the oil volume in the tank.
Check the limit value.
Check the sensor output signal.
Check/increase the oil volume in the tank.
Check the limit value.
Check the sensor output signal.
Check the limit value.
Check the sensor output signal.
Change the oil.
Check the limit value.
Check the sensor output signal.
Change the oil.
Check the limit value.
Check the sensor output signal.
Change the oil.
Check the limit value.
Check the sensor output signal.
Change the oil.
Check the limit value.
Check the sensor output signal.
Replace the filter element of the pressure filter.
Check the limit value.
Check the sensor output signal.
Reduce the load.
Check the oil cooling pump.
Check the water cooling unit.
Check the limit value.
Check the sensor output signal.
Heat the oil.
Check the limit value.
Check the sensor output signal.
Check the degassing function.
Reduce the required flow.
Check the limit value.
Check the sensor output signal.
Check the drainage function.
Reduce the required flow.
Check the limit value.
Check the sensor output signal.
Check the pump and replace it, if necessary.