Emergency Stop Linking Between Safety Controller Of Apas Assistant And Customer System Controller; Incorporation Of End Effector Emergency Stop Into Safety Controller Of Apas Assistant - Bosch Rexroth APAS assistant K1100-10i Installation Instructions Manual

Table of Contents

Advertisement

3.5.2
EMERGENCY STOP linking between safety controller of APAS assistant
and customer system controller
Safety module
PIN
BMK
K911A
6
K911A
16
K911A
7
K911A
17
K911B
0
K911B
1
PLC-R -> KRC
0
3.5.3
Incorporation of end effector EMERGENCY STOP into safety controller of
APAS assistant
Safety module
PIN
BMK
K911A
4
K911A
14
K911A
5
K911A
15
3 842 565 050/2019-11 APAS assistant K1100-10i V01.00.00 - V01.00.99, Bosch Rexroth AG
Signal direction
English description
CUSTOMER -> PLC-R
External emergency stop safe input
channel 1 (IN-CH1)
CUSTOMER -> PLC-R
External emergency stop safe clock output
channel 1 (CLK-CH1)
CUSTOMER -> PLC-R
External emergency stop safe input
channel 2 (IN-CH2)
CUSTOMER -> PLC-R
External emergency stop safe clock output
channel 2 (CLK-CH2)
PLC-R -> CUSTOMER
Local emergency stop on APAS assistant
clock output channel 1 (CLK-CH1)
PLC-R -> CUSTOMER
Local emergency stop on APAS assistant
clock output channel 2 (CLK-CH2)
1
Input for external EMERGENCY STOP
Signal direction
English description
EE -> PLC-R
End effector emergency stop safe input
channel 1 (IN-CH1)
PLC-R -> EE
End effector emergency stop safe clock
output channel 1 (CLK-CH1)
EE -> PLC-R
End effector emergency stop safe input
channel 1 (IN-CH2)
PLC-R -> EE
End effector emergency stop safe clock
output channel 1 (CLK-CH2)
Product description
21/68

Advertisement

Table of Contents
loading

Table of Contents