7-110
Error Messages
F2101 It was impossible to address MMC
Cause
Failure occurs sporadically (firmware error)
MMC has not been plugged in correctly or is
defective
MMC slot in control section is defective
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
When accessing the Multi Media Card (MMC) an error occurred.
Remedy
Clear error and contact our service department in order
to get a firmware update
Clear error and check MMC or plug it in correctly. If error
occurs again when MMC is accessed, MMC has to be
replaced
Clear error and check MMC slot. If error occurs again
when MMC is accessed, control section or entire drive
controller has to be replaced
See also Functional Description "MultiMediaCard (MMC)"
F2101 - Attributes