Table 8–6: 745 MEMORY MAP (Sheet 45 of 57)
GROUP
ADDR
DESCRIPTION
(HEX)
FREQUENCY
22D0
Frequency Decay Function
DECAY
22D1
Frequency Decay Target
22D2
Frequency Decay Minimum Operating Current
22D3
Frequency Decay Threshold
22D4
Frequency Decay Rate 1
22D5
Frequency Decay Rate 2
22D6
Frequency Decay Rate 3
22D7
Frequency Decay Rate 4
22D8
Frequency Decay Block
22D9
Frequency Decay Current Sensing
22DA
Frequency Decay Minimum Operating Voltage
22DB
Frequency Decay Delay
22DC
Reserved
22DF
Reserved
OVER-
22E0
Overfrequency Function
FREQUENCY
22E1
Overfrequency Target
22E2
Overfrequency Minimum Operating Current
22E3
Overfrequency Pickup
22E4
Overfrequency Delay
22E5
Overfrequency Block
22E6
Overfrequency Current Sensing
22E7
Overfrequency Minimum Operating Voltage
22E8
Reserved
22EF
Reserved
5th
22F0
5th Harmonic Level Function
HARMONIC
22F1
5th Harmonic Level Target
LEVEL
22F2
5th Harmonic Level Min.Operating Current
22F3
5th Harmonic Level Pickup
22F4
5th Harmonic Level Delay
22F5
5th Harmonic Level Block
22F6
Reserved
22FF
Reserved
VOLTS-PER-
2300
Volts-Per-Hertz 1 Function
HERTZ 1
2301
Volts-Per-Hertz 1 Target
2302
Volts-Per-Hertz 1 Minimum Operating Voltage
GE Power Management
RANGE
0.05 to 1.00
45.00 to 59.99
0.1 to 5.0
0.1 to 5.0
0.1 to 5.0
0.1 to 5.0
0.10 to 0.99
0.00 to 600.00
0.05 to 1.00
50.01 to 65.00
0.00 to 600.00
0.10 to 0.99
0.03 to 1.00
0.1 to 99.9
0 to 60000
0.10 to 0.99
745 Transformer Management Relay
8.3 MODBUS MEMORY MAP
STEP
UNITS
FORMAT
VALUE
---
---
---
---
---
---
× CT
0.01
0.01
Hz
0.1
Hz/s
0.1
Hz/s
0.1
Hz/s
0.1
Hz/s
---
---
---
---
---
---
× VT
0.01
0.01
s
---
---
---
---
---
---
× CT
0.01
0.01
Hz
0.01
s
---
---
---
---
---
---
× VT
0.01
---
---
---
---
---
---
× CT
0.01
0.1
% ƒo
1
s
---
---
---
---
---
---
---
---
---
× VT
0.01
FACTORY
CODE
DEFAULT
F30
0 = Disabled
F46
1 = Latched
20 = 0.20 × CT
F3
F3
5950 = 59.5 Hz
F2
4 = 0.4 Hz/s
F2
10 = 1.0 Hz/s
F2
20 = 2.0 Hz/s
F2
40 = 4.0 Hz/s
F87
0 = Disabled
F30
1 = Enabled
50 = 0.50 × VT
F3
F3
0 = 0.00 s
F30
0 = Disabled
F46
1 = Latched
20 = 0.20 × CT
F3
F3
6050 = 60.5 Hz
F3
500 = 5.00 s
F87
0 = Disabled
F30
1 = Enabled
50 = 0.50 × VT
F3
F30
0 = Disabled
F46
0 = Self-reset
8
10 = 0.10 × CT
F3
F1
100 = 10.0% ƒ
o
F1
10 s
F87
0 = Disabled
F30
0 = Disabled
F46
0 = Self-reset
10 = 0.10 × VT
F3
8-61