Sign In
Upload
Manuals
Brands
York Manuals
Chiller
YCAL0027EC
York YCAL0027EC Air-Cooled Scroll Chiller Manuals
Manuals and User Guides for York YCAL0027EC Air-Cooled Scroll Chiller. We have
2
York YCAL0027EC Air-Cooled Scroll Chiller manuals available for free PDF download: Installation Operation & Maintenance
York YCAL0027EC Installation Operation & Maintenance (156 pages)
AIR-COOLED LIQUID CHILLERS HERMETIC SCROLL
Brand:
York
| Category:
Chiller
| Size: 8.49 MB
Table of Contents
Table of Contents
4
Section 1 - General Chiller Information & Safety
7
Introduction
7
Warranty
7
Safety
7
Standards for Safety
7
Responsibility for Safety
8
About this Manual
8
Misuse of Equipment
8
Suitability for Application
8
Structural Support
8
Mechanical Strength
8
General Access
8
Pressure Systems
9
Electrical
9
Rotating Parts
9
Sharp Edges
9
Refrigerant & Oils
9
High Temperature & Pressure Cleaning
9
Emergency Shutdown
9
Section 2 - Product Description
10
Introduction
10
General System Description
10
Compressor
10
Cooler
10
Condenser
11
Millenuim Control Center
11
Power Panel
12
Accessories & Options
13
Power Options
13
Control Options
13
Compressor, Piping, Evaporator Options
14
Condenser Cabinet Options
14
Sound Reduction Options
15
Unit Components
16
Control / Power Panel Components
17
Unit Nomenclature
18
Product Identification Number
18
Refrigerant Flow Diagram
23
Section 3 -Handling and Storage
24
Delivery and Storage
24
Inspection
24
Moving the Chiller
24
Lifting Weights
24
Unit Rigging
25
Section 4 - Installation
26
Installation Checklist
26
Handling
26
Inspection
26
Location Clearances
26
Foundation
27
Ground Level Locations
27
Rooftop Locations
27
Noise Sensitive Locations
27
Spring Isolators
27
Compressor Mounting
27
Remote Cooler Option
27
Chilled Liquid Piping
27
General Requirements
28
Ductwork Connection
28
Wiring
28
Evaporator Pump Start Contacts
29
System Run Contacts
29
Alarm Status
29
Remote Start/Stop Contacts
29
Remote Emergency Cutoff
29
PWM Input
29
Load Limit Input
29
Flow Switch Input
29
Compressor Heaters
29
Single Point Supply Connection
30
Control Wiring
31
Section 5 - Commissioning
32
Commissioning
32
Preparation - Power off
32
Inspection
32
Refrigerant Charge
32
Service and Oil Line Valves
32
Compressor Oil
32
Fans
32
Isolator Protection
32
Control Panel
32
Preparation - Power on
33
Switch Settings
33
Compressor Heaters
33
Water System
33
Flow Switch
33
Temperature Sensor(S)
33
Equipment Startup Checklist
34
Checking the System Prior to Initial Start-Up (no Power)
34
Unit Checks
34
Compressor Heaters (Power on 24 Hrs. Prior to Start)
34
Panel Checks (Power on - both Unit Switch Off)
34
Setpoints Entry List
35
Checking Superheat & Subcooling
36
Leak Checking
36
Unit Operating Sequence
37
Section 6 - Technical Data
38
Operational Limitations (English)
38
Temperatures and Flows
38
Voltage Limitations
38
Ethylene Glycol Correction Factors
39
Operational Limitations (Si)
40
Temperatures and Flows
40
Voltage Limitations
40
Ethylene Glycol Correction Factors
41
Physical Data (English)
42
Sound Data (English)
44
Electrical Data
45
Electrical Notes
47
Wiring Diagrams
48
Dimensions
60
Technical Data (Clearances)
84
Isolators
85
Section 7 - Unit Controls
92
Introduction
92
Microprocessor Board
92
Unit Switch
93
Display
93
Keypad
93
Battery Back-Up
93
Transformer Status
93
Single System Select Programming # of Compressors
93
"Status" Key
94
Unit Status
94
General Status Message
94
Fault Safety Status Messages
96
System Safties
96
Unit Safeties
98
Unit Warning
98
Status Key Messages
99
Quick Reference List
99
Display/Print Keys
100
Oper Data Key
100
Oper Data Quick Reference List
103
Print Key
104
Operating Data Printout
104
History Printout
105
History Displays
105
Software Version
107
"Entry" Keys
108
Up & down Arrow Keys
108
Enter/Adv Key
108
Setpoints Key
109
Cooling Setpoints
109
Leaving Chilled Liquid Control
109
Return Chilled Liquid Control
110
Remote Setpoint Control
110
Schedule/Advance Day Key
110
Program Key
112
System Trip Volts
113
Unit Trip Volts
114
Program Key Limits and Defaults
114
Setpoints Quick Reference List
115
"Unit" Keys
116
Options Key
116
Clock
119
Unit Keys Programming Quick Reference List
120
Section 8 - Unit Operation
121
Capacity Control
121
Suction Pressure Limit Controls
121
Discharge Pressure Limit Controls
121
Leaving Chilled Liquid Control
121
Override to Reduce Cycling
122
Leaving Chilled Liquid System and Compressor Sequencing
122
Return Liquid Control
122
Anti-Recycle Timer
123
Anti-Coincidence Timer
123
Evaporator Pump Control
123
Evaporator Heater Control
123
Pumpdown Control
123
Electronic Expansion Valve (Eev)
123
MOP Feature
123
Valve Preheat
123
Inputs
124
Outputs
124
Program
124
Safeties
124
Condenser Fan Control (Std)
124
Low Ambient Control Option
126
0012 - 0021 Units
126
General
126
Potentiometers Configuration
126
Wiring
127
Programming
128
Low Ambient Control Option
129
0025 - 0032 Units
129
General
129
Potentiometers Configuration
130
Wiring
130
Programming
131
Load Limiting
132
Compressor Run Status
132
Alarm Status
132
Ems-Pwm Remote Temperature Reset
132
Bas/Ems Temperature Reset Option
133
Section 9
136
Service and Troubleshooting
136
Clearing History Buffers
136
Service Mode
136
Service Mode - Outputs
136
Service Mode - Chiller Configuration
136
Service Mode - Inputs
137
Control Inputs/Outputs
138
Microboard Layout
139
Checking Inputs and Outputs
140
Digital Inputs
140
Analog Inputs - Temperature
140
Outside Air Sensor
140
Liquid & Refrigerant Sensor Test Points
141
Analog Inputs - Pressure
142
Digital Outputs
143
Keypad
144
Optional Printer Installation
145
Parts
145
Assembly and Wiring
145
Obtaining a Printout
145
Troubleshooting
146
Section 10 - Maintenance
150
Important
150
Compressors
150
Oil Level Check
150
Oil Analysis
150
Condenser Fan Motors
150
Condenser Coils
150
Operating Parameters
150
On-Board Battery Back-Up
150
Overall Unit Inspection
150
Isn Control
151
Received Data (Control Data)
151
Transmitted Data
151
Isn Operational & Fault Codes
153
Recommended Spare Parts
154
Advertisement
York YCAL0027EC Installation Operation & Maintenance (166 pages)
AIR-COOLED SCROLL CHILLERS STYLE D WITH IPU II and I/O BOARDS (60 Hz) 9 1/2 TON TO 28 TON
Brand:
York
| Category:
Chiller
| Size: 6.79 MB
Table of Contents
Table of Contents
4
List of Figures
10
Section 1 - General Chiller Information and Safety
13
Introduction
13
Safety
13
Standards for Safety
13
Warranty
13
About this Manual
14
Misuse of Equipment
14
Suitability for Application
14
Structural Support
14
Mechanical Strength
14
General Access
14
Pressure Systems
15
Electrical
15
Rotating Parts
15
Sharp Edges
15
Refrigerants and Oils
15
High Temperature and Pressure Cleaning
15
Emergency Shutdown
15
Responsibility for Safety
14
Section 2 - Product Description
17
Introduction
17
General System Description
17
Compressors
17
Cooler
17
Condenser
18
Millennium Control Center
18
Power Panel
19
Accessories and Options
20
Power Options
20
Control Options
20
Compressor, Piping, Evaporator Options
21
Condenser and Cabinet Options
21
Sound Reduction Options
22
Unit Components
23
Fig. 1 - Unit Components
23
Control / Power Panel Components
24
Fig. 2 - Control/Power Panel Components
24
Product Identification Number (Pin)
25
Basic Unit Nomenclature
25
Refrigerant Flow Diagram
30
Fig. 3 - Refrigerant Flow Diagram
30
Inspection
31
Section 3 - Handling and Storage
31
Moving the Chiller
31
Lifting Weights
31
Unit Rigging
32
Fig. 4 - Unit Rigging/Lifting
32
Delivery and Storage
31
Section 4 - Installation
33
Installation Checklist
33
Handling
33
Inspection
33
Location and Clearances
33
Foundation
34
Ground Level Locations
34
Rooftop Locations
34
Noise Sensitive Locations
34
Spring Isolators (Optional)
34
Compressor Mounting
34
Remote Cooler Option
34
Chilled Liquid Piping
34
Duct Work Connection
35
Wiring
35
Evaporator Pump Start Contacts
36
System Run Contacts
36
Alarm Status Contacts
36
Remote Start/Stop Contacts
36
Remote Emergency Cutoff
36
PWM Input
36
Load Limit Input
36
Flow Switch Input
36
Compressor Heaters
36
Single Point Supply Connection
37
Fig. 5 - Single-Point Supply Connection - Terminal Block, Non-Fused Disconnect Switch or Circuit Breaker (0012 - 0032)
37
Control Wiring
38
Fig. 6 - Control Wiring
38
Preparation - Power off
39
Inspection
39
Refrigerant Charge
39
Service and Oil Line Valves
39
Compressor Oil
39
Fans
39
Isolation / Protection
39
Control Panel
39
Power Connections
39
Supply Voltage
40
Section 5 - Commissioning
39
Preparation - Power on
40
Switch Settings
40
Compressor Heaters
40
Water System
40
Flow Switch
40
Temperature Sensor(S)
40
Equipment Startup Checklist
41
Checking the System Prior to Initial Start (no Power)
41
Compressor Heaters (Power on - 24 Hours Prior to Start)
41
Panel Checks (Power on - both Unit Switches OFF)
41
Setpoints Entry List
42
Table 1 - Setpoints Entry List
42
Checking Superheat and Subcooling
43
Leak Checking
43
Unit Operating Sequence
44
Section 6 - Technical Data
45
Operational Limitations (English)
45
Temperatures and Flows
45
Voltage Limitations
45
Table 2 - Temperatures and Flows
45
Table 3 - Voltage Limitations
45
Ethylene Glycol Correction Factors
46
Table 4 - Ethylene Glycol Correction Factors
46
Operational Limitations (Si)
47
Temperatures and Flows
47
Voltage Limitations
47
Table 5 - Temperatures and Flows (Si)
47
Table 6 - Voltage Limitations
47
Ethylene Glycol Correction Factors
48
Table 7 - Ethylene Glycol Correction Factors
48
Physical Data (English)
49
Table 8 - Physical Data (English)
49
Sound Data (English)
50
Table 9 - Sound Data (English)
50
Electrical Data (English)
52
Table 10 - Ycal012 - Electrical Data (English)
52
Table 11 - Micro Panel Power Supply
54
Table 12 - Voltage Range
54
Electrical Notes and Legend
55
Fig. 7 - Control Circuit, Single
56
Fig. 8 - Control Circuit, Single
58
Fig. 9 - Power Circuit, Single
60
Fig. 10 - Power Circuit, Single
61
Fig. 11 - Connection Diagram
62
Fig. 12 - Connection Diagram
63
Fig. 13 - Connection Diagram
64
Fig. 14 - Connection Diagram - Standard Unit
65
Dimensions
68
Fig. 15 - Unit Clearances
90
Technical Data - Clearances
90
Isolators
91
Section 7 - Unit Controls
99
Introduction
99
Microprocessor Board
99
Unit Switch
100
Display
100
Keypad
100
Battery Back-Up
100
Transformer
100
Single System Select and Programming # of Compressors
100
Status" Key
101
General Status Messages
101
Unit Status
101
Fault Safety Status Messages
103
System Safeties
103
Unit Safeties
105
Table 13 - Status Key Messages Quick Reference List
106
Table 14 - Operation Data
110
Table 15 - Cooling Setpoints, Programmable Limits and Defaults
118
Table 16 - Program Key Limits and Defaults
121
Table 17 - Setpoints Quick Reference List
122
Table 18 - Unit Keys Programming Quick Reference List
128
Fig. 16 - Setpoint Adjust
130
Fig. 16A - Leaving Water Temperature Control Example
130
Table 19 - Ycal0012 - Ycal0032 Condenser Fan Control Using Outdoor
132
Ambient Temperature and Discharge Pressure
132
Pressure Only
132
Table 20 - Ycal0012 - Ycal0032 Condenser Fan Control Using Discharge
132
Fig. 17 - Typical Vfd Location
133
Fig. 18 - Liquid Line Sensing Bulb Location
133
Fig. 19 - Potentiometer Settings
133
Fig. 20 - Wiring
134
Table 21 - Ycal0012 - 0021 Vfd Low Ambient Option - Condenser Fan
135
Control Operation
135
Fig. 21 - Typical Vfd Enclosure Locations
136
Fig. 22 - Typical Vfd Enclosure Configurations
136
Fig. 23 - Inverter Power Wiring Schematic
137
Fig. 24 - Potentiometer Settings
137
Fig. 25 - Inverter Wiring
138
Table 22 - Ycal0025-0032 Vfd Low Ambient Option - Condenser Fan
138
Control Operation
138
Table 23 - Compressor Operation - Load Limiting
139
Fig. 26 - Field and Factory Electrical Connections Optional Remote Temperature Reset Board
141
Table 24 - Microboard Digital Inputs
145
Table 25 - Microboard Digital Outputs
145
Table 26 - Microboard Analog Inputs
145
Table 27 - Microboard Analog Outputs
145
Fig. 27 - Ipu II & I/O Layout
146
Table 28 - Outdoor Air Sensor Temperature/Voltage/Resistance Correlation
147
Table 29 - Entering/Leaving Chilled Liquid Temp. Sensor, Cooler Inlet Temperature Sensor, and Suction Temperature Sensor: Temperature/Voltage Correlation
148
Fig. 28 - I/O Board Relay Contact Architecture
150
Fig. 29 - Printer to Microboard Electrical Connections
151
Table 30 - Troubleshooting
152
Table 31 - Isn Received Data
157
Table 32 - Isn Transmitted Data
157
Table 33 - Isn Operational and Fault Codes
159
Table 34 - Minimum, Maximum and Default Values
161
Table 35 - Real Time Error Numbers
161
Advertisement
Related Products
York YCAL0028
York YCAL0022
York YCAL0020SC
York YCAL0024SC
York YCAL0020EB
York YCAL0024EB
York YCAL0022EE
York YCAL0028EE
York YCAL0021EC
York YCAL0025EC
York Categories
Air Conditioner
Heat Pump
Chiller
Furnace
Air Handlers
More York Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL