Sign In
Upload
Manuals
Brands
YOKOGAWA Manuals
Transmitter
Dpharp EJX210A
YOKOGAWA Dpharp EJX210A Manuals
Manuals and User Guides for YOKOGAWA Dpharp EJX210A. We have
3
YOKOGAWA Dpharp EJX210A manuals available for free PDF download: User Manual, Installation Manual
YOKOGAWA Dpharp EJX210A User Manual (61 pages)
Flange Mounted Differential Pressure Transmitters
Brand:
YOKOGAWA
| Category:
Transmitter
| Size: 5 MB
Table of Contents
Table of Contents
2
Introduction
5
Regarding this Manual
6
Trademarks
6
Safe Use of this Product
7
Warranty
9
Handling Cautions
10
Model and Specifications Check
10
Unpacking
10
Storage
10
Selecting the Installation Location
11
Pressure Connection
11
Waterproofing of Cable Conduit Connections
11
Restrictions on Use of Radio Transceivers
12
Insulation Resistance and Dielectric Strength Test
12
Installation of an Explosion-Protected Instrument
13
FM Approval
13
CSA Certification
15
ATEX Certification
18
Iecex Certification
22
EMC Conformity Standards
25
Pressure Equipment Directive (PED)
26
EU Rohs Directive
26
Safety Requirement Standards
26
Component Names
27
Installation
28
Precautions
28
Mounting
28
Rotating Transmitter Section
29
Changing Integral Indicator Direction
29
Mounting the Flushing Connection Ring
30
Mounting to Pressure Detector Section
30
Mounting to Process Flange
30
Affixing the Teflon Film
31
Installing Impulse Piping
32
Impulse Piping Installation Precautions
32
Connecting Impulse Piping to the Transmitter
32
Routing the Impulse Piping
32
Impulse Piping Connection Examples
33
Wiring
34
Wiring Precautions
34
Selecting the Wiring Materials
34
Connections of External Wiring to Terminal Box
34
Power Supply Wiring Connection
35
External Indicator Connection
35
Communicator Connection
35
Check Meter Connection
36
Status Output Connection
36
Wiring
36
Loop Configuration
36
Wiring Installation
37
Grounding
38
Power Supply Voltage and Load Resistance
38
Operation
39
Preparation for Starting Operation
39
Zero Point Adjustment
41
Starting Operation
42
Shutting down Operation
42
Venting or Draining Transmitter Pressure-Detector Section
42
Draining Condensate
43
Venting Gas
43
Draining Condensate for Flushing Connection Ring
43
Venting Gas for Flushing Connection Ring
43
Local Parameter Setting
44
Local Parameter Setting (LPS) Overview
44
Activating Local Parameter Setting
46
Parameter Setting Review
46
Loop Test Configuration
47
Tag Number Configuration
47
Pressure Unit Configuration
47
Pressure Lrv/Urv Configuration
48
Damping Time Constant Configuration
48
Output Mode Configuration
48
Display Out 1 Configuration
48
Re-Range by Applying Actual Pressure (LRV/URV)
49
Device Information Display
49
Save or Cancel
49
Abort Configuration
50
Abort Configuration (Menu)
50
Abort Configuration (Parameter)
50
Local Parameter Setting Lock
50
Others
50
Maintenance
51
Overview
51
Calibration Instruments Selection
51
Calibration
51
Disassembly and Reassembly
53
Replacing the Integral Indicator
53
Replacing the CPU Board Assembly
54
Replacing the Process Connector Gasket
55
Troubleshooting
55
Basic Troubleshooting
55
Troubleshooting Flowcharts
56
Alarms and Countermeasures
58
General Specifications
59
Advertisement
YOKOGAWA Dpharp EJX210A User Manual (54 pages)
Flange Mounted Differential Pressure Transmitters
Brand:
YOKOGAWA
| Category:
Transmitter
| Size: 1 MB
Table of Contents
Table of Contents
2
1 Introduction
4
Regarding this Manual
4
Safe Use of this Product
5
Warranty
6
ATEX Documentation
7
2 Handling Cautions
8
Model and Specifications Check
8
Unpacking
8
Storage
8
Selecting the Installation Location
9
Pressure Connection
9
Waterproofing of Cable Conduit Connections
9
Restrictions on Use of Radio Transceivers
9
Insulation Resistance and Dielectric Strength Test
9
Installation of an Explosion-Protected Instrument
10
FM Approval
10
CSA Certification
12
CENELEC ATEX (KEMA) Certification
14
Iecex Certification
17
EMC Conformity Standards
18
Pressure Equipment Directive (PED)
18
Low Voltage Directive
18
3 Component Names
19
4 Installation
20
Precautions
20
Mounting
20
Rotating Transmitter Section
20
Changing Integral Indicator Direction
21
Mounting the Flushing Connection Ring
21
Mounting to Pressure Detector Section
21
Mounting to Process Flange
22
Affixing the Teflon Film
22
5 Installing Impulse Piping
23
Impulse Piping Installation Precautions
23
Connecting Impulse Piping to the Transmitter
23
Routing the Impulse Piping
23
Impulse Piping Connection Examples
24
6 Wiring
25
Wiring Precautions
25
Selecting the Wiring Materials
25
Connections of External Wiring to Terminal Box
25
Power Supply Wiring Connection
25
External Indicator Connection
25
Communicator Connection
25
Check Meter Connection
26
Status Output Connection
26
Wiring
26
Loop Configuration
26
General-Use Type and Flameproof Type
26
Intrinsically Safe Type
26
Wiring Installation
26
General-Use Type and Intrinsically Safe Type
26
Flameproof Type
27
Grounding
27
Power Supply Voltage and Load Resistance
27
7 Operation
28
Preparation for Starting Operation
28
Zero Point Adjustment
29
Starting Operation
30
Shutting down Operation
30
Venting or Draining Transmitter Pressure-Detector Section
30
Draining Condensate
30
Venting Gas
30
Draining Condensate for Flushing Connection Ring
31
Venting Gas for Flushing Connection Ring
31
Setting the Range Using the Range-Setting Switch
31
8 Maintenance
33
Overview
33
Calibration Instruments Selection
33
Calibration
33
Disassembly and Reassembly
35
Replacing the Integral Indicator
35
Replacing the CPU Board Assembly
36
Replacing the Process Connector Gasket
36
Troubleshooting
37
Basic Troubleshooting
37
Troubleshooting Flowcharts
37
Alarms and Countermeasures
39
9 General Specifications
40
Standard Specifications
40
Model and Suffix Codes
43
OPTIONAL SPECIFICATIONS (for Explosion Protected Type)
49
Dimensions
51
YOKOGAWA Dpharp EJX210A Installation Manual (60 pages)
Differential Pressure and Pressure Transmitters
Brand:
YOKOGAWA
| Category:
Transmitter
| Size: 11 MB
Table of Contents
Table of Contents
1
1 Introduction
2
For Safe Use of Product
4
Warranty
6
2 Handling Cautions
7
3 Installation
35
Mounting
35
4 Installing Impulse Piping
40
5 Wiring
45
Wiring Precautions
45
Wiring
48
Grounding
52
6 Operation
53
Preparation for Starting Operation
53
7 Errors and Countermeasures
56
Advertisement
Advertisement
Related Products
YOKOGAWA DP harp EJX210B
YOKOGAWA DP harp EJX210A
YOKOGAWA Dpharp EJX130A
YOKOGAWA Dpharp EJX430A
YOKOGAWA Dpharp EJX440A
YOKOGAWA Dpharp EJX910A
YOKOGAWA DPharp EJX***A Series
YOKOGAWA DPharp EJX120A
YOKOGAWA DP harp EJX510A
YOKOGAWA DP harp EJX530A
YOKOGAWA Categories
Measuring Instruments
Test Equipment
Transmitter
Controller
Media Converter
More YOKOGAWA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL