Table of Contents
2
No "Welcome" Message on Display. no Light on the Main Switch (Early Model)
10
No Light in the Display
10
Network Fail !!" "Call Service
11
Foot Control Fail" "Call Service
11
Power Driver Fail!!" "Call Service
12
Stand Control Fail !!" "Call Service
12
Water Leak" "Call Service
12
Unit Not Ready
12
"No Water Flow
13
Chair Sync Failed
13
Code Block Required" "Call Service
13
Cs Error
13
Missing DMX Pcb
13
Wrong Instrument
13
Wrong Susp Pcb
14
Check White Bottle
14
Check Yellow Bottle
14
Suction Clean Fail" "Call Service
14
LED D3 Is off (Power Supply Chair)
15
LED D2 Is off
15
LED D1 Is off (Transformer and Power Supply)
15
LED D1 and D3 Are off
15
D1 LED Is off (24VAC)
16
D2 LED Is off ±34VDC
16
D3 LED Is off ±34VDC
16
D6 LED Is off 5V, 12V, 24VDC
16
All Leds on the "Power Supply PCB" Are off and Led's on "Mains PCB" Are on
16
Precision Voltage Measurement
16
Procedure
17
Cause
18
Purpose
27
Water Arrives on the Syringe but Not Distributed on the Other Instruments
27
It Is Not Possible to Adjust the Flow Rate on the Instruments
27
Point of Measurement
27
LED D110 Remains off When the Instrument Is Pulled Forward
28
Wrong Instrument
28
Wrong Susp. PCB
28
Information
29
Voltage Measurement on the Suspension PCB Connector (CA-100, CA-101
29
Syringe
32
Block Syringe, An-510
33
No Water or Air on the Syringe Block
33
No Spray Air on the Syringe Module
33
Syringe 3F / 6F
34
Failure Description
34
Syringe Not Activated When the Suspension Is Pulled
34
Syringe Activated When Not Pulled
34
No Water
34
No Air
34
Syringe 6F
35
No Hot Water/Air
35
Micromotor Mc3 Bien Air
36
Micromotor Not Activated When the Suspension Is Pulled
37
Micromotor Is Active While the Suspension Cord Is Not Pulled
37
The Motor Does Not Run When the Pedal Is Activated
37
No Light
38
No Water
38
No Air Spray
39
No "Cool Air
39
Micromotor Mx2 Bien Air
40
Specific Error Connected with Micromotor Type MX2
41
The Motor Does Not Run When the Pedal Is Activated
41
Missing DMX PCB
41
Turbine
42
The Turbine Is Not Activated When the Suspension Is Pulled
43
The Turbine Is Active While the Suspension Cord Is Not Pulled
43
The Turbine Does Not Run When the Pedal Is Activated
43
No Light
44
No Water
44
No Air Spray
45
Scaler
46
The Scaler Is Not Activated When the Suspension Is Pulled
46
The Scaler Is Active While the Suspension Cord Is Not Pulled
47
The Scaler Does Not Run When the Pedal Is Activated
47
No Water
48
Light Curing System - Lysta 88 / 89 & Odontocure
49
Light Curing Lamp Does Not Work When Activated
49
DÜRR CAMERA / VIDEO IX, IX HD, HD Smart
50
The Camera Does Not Work When the Suspension Is Activated
50
The Camera Is Active When the Suspension Is at Rest
51
No Light
51
Image Cloudy, Milky
52
Image too Dark
52
No Image
52
The Camera Vibrates When Pressing the Trigger Button, but no Picture Is Displayed
52
Moving Image Judders
52
The Image Is Blurred
53
Camera Not Detected by the Software
53
Camera Is Not Correctly Detected When PC Runs Windows 7
53
Camera Is Recognized as Vistacam IX HD Without the Interchangeable Head
53
The Trigger Function Is Not Working
53
Interchangeable Head Not Engaging
53
Test Cable for Dürr Vistacam
53
Basic Configuration
55
Suction Clean System
55
Water Treatment
55
Backflow Prevention
55
Water Leak!!" "Call Service
56
Water Pressure Failure on the Instrument Bridge
56
Air Pressure Failure on the Instrument Bridge
56
Fault in Air Pressure to Instrument Bridge
57
No Flush or Rinse
57
No Cup Filling
57
The Liquid Detection Sensor Pins Do Not Work Properly
59
Lower LED off (Mixing Cup Filled)
59
Upper LED Remains off When Water Reaches the Short Liquid Detector Sensor Probes
59
Information
59
Water Clean Mixing Cup Is Detected as Empty When the Cup Is Filled
60
The "Water Clean" Dispenser Detected as "Low" When Full (White Bottle)
61
The Liquid in the Bottle Does Not Circulate
61
Information
61
AN-374 Level Sensor PCB
61
No Water in the Container
62
Overflow (Mixing Cup)
63
Air Bubbles "Shoots" Water out of Mixing Cup
63
Valves & Contacts Connections in the "Basic Configuration" and "Suction Cleaning
65
Overflow (Mixing Cup)
65
The Mixing Cup Is Detected as Empty When Filled
66
The Suction Cleaning Liquid Is Detected as "Low" While the Bottle Is Full (Yellow Bottle)
66
Unpleasant Smells from the Suction
66
Suction Does Not Start When One of the Suction Hoses Is Lifted but Suction Motor Starts
69
Suction Starts When the Unit Is Switched on
69
No Suction: (Valves Activated / Spittoon Valve / CAS1 / Amalgam Separator Activated)
69
Connection Diagram
69
The Chair Does Not Run Properly (Hacking While Moving)
70
No Movement of the Chair When the Joystick or Control Pedal Is Activated
70
The Backrest Motor Does Not Work
71
The Backrest Motor Locks up When Going up
71
Major Cases
71
Signal Measurement: Rectangular Shaped Signal
71
Special Case: the Backrest Motor Does Not Stop When Reaching Topmost Position
72
Out of Synchronisation
72
Electrical Safety Tips
72
Electrical Work Procedure
72
Reversal of the Motor Polarities
72
Before Proceeding
73
Handling
73
Advice
73
Synchronization
73
Mechanical Work Procedure
74
Disassembling of the Drive Bearer
74
Powering up the Unit
74
Advice
74
Chair Synchronisation
75
To Synchronise the Chair, Proceed as Follows
75
Note that this Description Refers to Firmware Version 1.51 or Later
75
Alternative Procedure
75
Information
76
The XO Operating Lamp Does Not Switch When It Reaches Working Position 1 or 2
77
The OP Lamp Does Not Switch on When Placing the Hand under the Sensor
77
The OP Lamp LED Shines Faintly
77
How to Measure Voltage Output on OP Light
77
Display Shows " Foot Control Error" During Start-Up
78
Network Fail!! "Call Service
78
Nothing Happens When the Pedal Is Activated
79
No Picture on the Screen
80
Image Quality Problem
81
Screen Problem
81
Advisory
81
Spittoon Valves DÜRR
82
Cas 1 Dürr
82
Combi-Sepamatic Cs 1
82
Spittoon Valve Is Not Working
83
Suction Unit Does Not Start or Run Continuously
83
The Liquid Does Not Flow through
83
CAS1 Is Not Operational (Display Module Off)
85
The Yellow and Green Leds Are Lit, and a Melody Is Emitted
85
The Yellow LED Is On, the Red LED Flashes and an Acoustic Signal Is Emitted
85
The Green and Red Leds Flash Alternately, and the Acoustic Signal Is Emitted
85
The Orange Light Flashes, and the Acoustic Signal Is Emitted
85
The Water Is Not Drain Properly from the Cuspidor
85
Suction Power Is too Weak or Interrupted
85
Device Is Running Continuously
86
Device Is Generating High Vibrations
86
Water Is Not Drained out Properly
86
CS1 Does Not Start
87
Suction Line too Weak or Interrupted
87
Advertisement
XO FLEX Instructions For Use Manual (95 pages)
Brand:
XO
| Category:
Dental equipment
| Size: 6 MB
Table of Contents
Table of Contents
3
1 Extraordinary Dentistry
7
2 Installation
8
3 Operation
11
General
11
Switch the Unit on
12
Instrument Bridge in Parking Position
13
Foot Control
13
Function
13
Position the Foot Control
14
Xo Smart Link
15
Patient Chair
15
Foot Control of Patient Chair
15
Smaller Adjustments of Patient Chair
15
Safety
16
Supine Patient Position
16
Neck Rest
16
Child Cushion
17
Instrument Bridge in Working Position
17
Balanced Instruments
17
Four-Handed or solo Work
18
Working Positions
18
Instrument Control
21
Foot Control of Instruments
21
Instruments on the Instrument Bridge
21
Instrument Bridge Display
21
Syringe - Luzzani
22
Micromotor - Bien-Air MC3 / Bien-Air MX2
22
XO OSSEO Motor
23
Set-Up
23
Operation
24
Implant Surgery - Operation with XO Smart Link
25
Air Instrument
25
Ultrasonic Scalers
26
XO ODONTOSON 360 Ultrasonic Scaler
27
How to Use XO ODONTOSON 360
28
Changing the Instrument
29
XO ODONTOSON 360 with Antimicrobials and Sterile Saline
30
XO ODONTOCURE Curing Light
30
XO Peristaltic Pump
32
Disposable Irrigation Kit
32
Attaching the Pump Module
33
Attaching the Irrigation Tube
33
Irrigation Bag
35
Irrigation Reservoir
35
Designation of Instrument
36
Adjusting the Flow Level
37
Intraoral HD Video Camera
37
Operating Light
38
Position the Light
38
Switch the Light on and Adjust the Light Intensity
39
Automatic Functions
40
XO HD Display
40
Hand Instruments
41
Suction
42
Cuspidor and Cup Filler
42
Automatic Function
43
Assistant Call
43
Sound Generator and Sounds
44
System Messages
44
XO SEAT and XO STOOL
44
Xo Seat
45
Xo Stool
46
4 Configuration
48
Configuration of Patient Chair Positions
48
Configuration of General Unit and Patient Chair Functions
48
Configuration of Unit Instruments
49
5 Cleaning and Infection Control
53
Cleaning, Disinfection and Sterilization Procedures
53
Detergents and Disinfectants for Cleaning And/Or Disinfection of the Unit
53
General Cleaning of Unit and Patient Chair Surfaces
53
Cleaning of Comfort and Skai Fabric
54
General Disinfection of Unit Surfaces
54
Infection Control Instrument and Bridge Protection Pad
54
Autoclaving Handles
54
Disinfection of Instrument Hoses and Suspensions
55
Infection Control Luzzani Syringe
56
Infection Control Bien-Air Micromotors
56
Autoclaving of XO OSSEO Motor
56
Infection Control XO ODONTOSON 360
57
Infection Control XO ODONTOCURE Curing Light
57
Infection Control Other Instruments
58
Infection Control XO Peristaltic Pump
58
Disinfection of Light
58
Infection Control XO HD Display
59
Front Panel
59
Disinfection of Cuspidor Bowl and Cup Holder
59
Disinfection of Suction Lines
60
General
60
Suction Filters
61
Replacement of XO Suction Disinfection Cartridge
62
Disinfection of Unit Water Lines
63
Overnight Water Treatment
63
Intensive Water Treatment
64
Replacement of XO Water Clean Cartridge
64
6 Maintenance and Repairs
66
Foot Control
66
XO OSSEO Motor
66
Motor Repair
66
Xo Odontoson
66
Handpiece Repair
66
Tightening / Exchanging the Ferrite Rod
66
Xo Odontocure
67
Handpiece Repair
67
Manual Measurement of Curing Effectiveness
67
XO Peristaltic Pump
69
Adjustment of the Hand Instrument Table
69
Control of the Water Disinfection System
69
Maintenance and Replacement of Main Filter for Water Supply
70
Cuspidor Valve - Cleaning the Course Filter
70
Flushing of Cuspidor Drain
70
Suction Hoses
70
Air and Amalgam Separator
71
Dürr CS1 Combi-Sepamatic - Air Separator
71
Dürr CAS 1 Combi-Separator - Air and Amalgam Separator
71
7 Unit Messages and Remedial Actions
72
Error Messages
72
Service Messages and Remedial Actions
73
8 Preventive Service, Safety Inspections and Repairs
74
General
74
Preventive Service and Safety Inspection
74
Preventive Service and Safety Inspection a - 12, 36 Etc. Months after Installation
74
Preventive Service and Safety Inspection B - 24, 48 Etc. Months after Installation
74
Service Notification
74
Adjustment of the Arm Systems
75
Adjustment of Balanced Instrument Suspension Arms
75
Replacement of Operating Light Source
75
XO HD Display
75
9 Infection Control and Maintenance Checklist
76
10 Accessories, Detachable Parts and Consumables
78
Accessories
78
Detachable Parts
78
Consumables
79
Suggested Retail Prices
80
11 Legal
81
Modification of the Equipment
81
Warrantee
81
Expected Service Life
81
Rd Party Instruments and Accessories
82
Product Updates
82
Firmware Version
82
Applicable Standards
82
Electromagnetic Emission
82
Interference Immunity
83
Classification
84
Applied Parts
84
Marking Plate
84
Other Labels
85
Product Disposal Information
85
12 Symbols
86
13 Dimensions and Technical Data
89
Dimensions and Range of Movement
89
Technical Specifications
90
14 XO FLEX Quick Guide
93
Xo FLEX Installation Instructions Manual (59 pages)
Brand:
Xo
| Category:
Dental equipment
| Size: 6 MB
Table of Contents
Table of Contents
3
Introduction
5
Installation Requirements
6
Supplies and Connections
6
Dimensions of Operatory
8
Ceiling Height
8
Operating and Transport Conditions
8
Floor
10
Fuse Replacement
10
Necessary Tools
11
Standard Tools
11
Special Tools Supplied with the Unit
11
Necessary Special Tools Available from XO CARE
11
Other Special Necessary Tools
11
Transportation and Unpacking
12
Transport
12
Unpacking
12
Installation
15
Installation Kit
15
Installation of the Unit Stand
15
Installation of the Unit in a Concrete Floor
16
Installation of the Unit Stand in a Wooden Floor Structure
16
Seal Opening in the Floor
17
Positioning the Unit Stand
17
Alignment of the Unit Base
20
Alignment of the Supporting Leg
22
Checking Clearance between Base and Floor
23
Installation of the Unit on a Steel Plate
23
Fitting the Bridge Arm and Instrument Bridge
25
Over-The-Floor Installation
28
X-Ray Adaptor
28
Fitting of Operating Light
29
Unpacking the Operating Light
29
Fitting the Light Arm Post
29
Fitting the Light Arm Cylindric Cover
31
Ceiling Height Less than 255 CM
31
Fitting the Light Arm
32
Fitting the Brake
33
Fitting the Cables to the Operating Light
34
Fitting of XO HD Display
34
Assistant Call
39
Suction Hoses
39
Installation of Dürr Intra Oral Camera
40
Finalizing Installation of the Instrument Bridge
40
Connecting Water, Compressed Air, Suction/Drain and Power Supply
40
Connecting 230 V and the Suction Motor
41
Connecting Mains Supply Cable
41
Connecting Suction Motor Control Cable
42
Fitting the Patient Chair
42
Finalizing the Installation
44
Attach the Patient Chair Seat Upholstery
44
Fit the Cuspidor Bowl and Cup Holder
44
Fit XO Water Disinfection and XO Suction Disinfection Cartridges
44
Connection of External Equipment
45
Checking the Unit
46
Adjustment of the Instrument Balance Suspension
46
Start and Check the Unit
47
Finalizing the Installation
48
Adjusting the Unit
48
Adjusting the Air Instrument (Turbine), Drive Air and Cooling Air of the Micromotor
48
Adjusting the Balance Spring and Friction Brake in the Bridge Forearm
50
Adjusting the Pivoting Jonts of the Bridge Arm
51
Adjustment of the Friction Brakes in the Operating Light Arm and Display Arm
52
Adjusting the Cuspidor and Cup Filler
53
Handing the Unit over to the Users
55
Symbols
56
Advertisement
Xo FLEX Manual (6 pages)
RETROFIT OF QUICK CONNECTORS
Brand:
Xo
| Category:
Dental equipment
| Size: 0 MB
Advertisement
Related Products
Xo FLOW
Xo 4
Xo ODONTOSURGE
XO Categories
Ventilation Hood
Kitchen Appliances
Ice Maker
Dental equipment
Boat
More XO Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL