Manuals and User Guides for Woodward MRIK3-C. We have
1
Woodward MRIK3-C manual available for free PDF download: Manual
Woodward MRIK3-C Manual (90 pages)
Digital time overcurrent relay with Control function and auto reclosing
Brand:
Woodward
| Category:
Relays
| Size: 1 MB
Table of Contents
Table of Contents
3
1 Comments on the Manual
7
Information Concerning Liability and Warranty
7
Important Definitions
8
How to Use this Instruction
8
Electrostatic Discharge Awareness
9
2 Introduction and Application
10
3 Characteristics and Features
10
4 Design
11
Connections
11
Analog Input Circuits
13
Output Relays
13
Digital Inputs
13
Low/High Range of the Digital Inputs
14
Password
15
Code Jumpers
15
Password Programming
15
Front Plate (for -ICE Relay Type)
16
Indicating Leds
16
Adjusting Leds
16
Front Plates (for -ER/-XR-Relay Types)
17
Indicating Leds
17
Adjusting Leds
17
5 Working Principle
18
Analogue Circuits
18
Digital Circuits
18
Status Descriptions
18
Inactive
18
Reclaim Time" Tr
18
AR-Ready
19
AR-Starting" (Dead Time)
19
AR-Cycle" (Auto Reclosing)
19
AR-Blocked
19
Fast Trip Mode
19
Blocking Mode
19
Activating of AR
19
Description of the Status Transition
20
AR Information Inputs
20
Functional Sequence
21
Switching on MRIK3-C
21
Circuit Breaker Manual Closing
21
Circuit Breaker Manual Open
21
Starting AR
21
Unsuccessful Reclosing
22
Successful Reclosing
22
Repeated Reclosing
22
Supervision of the Circuit Breaker Ready Information
23
External Blocking
23
Time Sequence Diagrams of MRIK3-C
23
The Unit Is Programmed for Two Shots, Successful AR at the Second Shot
23
The Unit Is Programmed for Two Shots, Unsuccessful AR
24
Manual Closing of the Circuit Breaker to Faulty Lines
24
Unsuccessful AR
25
Earth Fault Protection
26
Generator Stator Earth Fault Protection
26
System Earth Fault Protection
26
Earth-Fault Directional Feature (ER/XR-Relay Type)
27
Control Functions
29
Introduction
29
Interlocking / Password for Control Mode
29
Operating Assignment of C.B. Control
29
Changing the Operating Assignment
29
Saving the Operating Assignment
30
Remote Switching on and off of the C.B
30
Switching on or off the C.B. Via the Front Panel (LCAL)
30
Handling of the Control Function
31
Display for the Control Functions
33
LED-Indication under Normal Mode
34
LED-Indication Auto Reclosing Conditions (AR)
35
Requirement on the Main Current Transformers
36
6 Operation and Adjustments
37
Displayed Text for Parameter Settings
37
Setting Procedure
38
Parameter Levels
39
System Parameters
40
Presentation of Measuring Values as Primary Quantities on the Display (Iprim Phase)
40
Display of Residual Voltage UE as Primary Quantity (Uprim/Usec)
40
Voltage Transformer Connection for Residual Voltage Measuring (3Pha/E-N/1:1)
40
Operation Cycle Counter
40
I2*T Operation Cycle Counter
41
Rated -Frequency
41
Indication of Pickup
41
Parameter Set Changeover Switch (P2)
41
Protection Parameters
42
Pickup Current for Phase Overcurrent Element
42
Trip Characteristics for the Phase Overcurrent Element (I>)
42
Tripping Time or Time Factor for the Phase Overcurrent Element
42
Fast/Time Tripping by Switch on of the CB for the Overcurrent Element
43
Reset Mode for the Trip Characteristics in Phase Current Path
43
Current Setting for High Set Element
43
Trip-Block for All Protection Elements
43
Trip Delay for High Set Element
43
Fast/Time Tripping by Switch on of the CB for the Short Circuit Element
44
Pickup Value for Residual Voltage (UE) (ER/XR-Relay Types)
44
Pickup Current for Earth Fault Element (IE>)
44
WARN/TRIP Changeover
44
Time Current Characteristics for Earth Fault Element (for E/X-Relay Types)
44
Tripping Time or Time Factor for the Earth Fault Element
44
Fast/Time Tripping by Switch on of the CB for the Earth Fault Low Set Element
44
Reset Mode for Inverse Time Tripping in Earth Current Path
45
Current Setting for High Set Element of Earth Fault Supervision (IE>>)
45
Trip Delay for High Set Element of Earth Fault Supervision
45
Fast/Time Tripping by Switch on of the CB for the Earth Fault High Set Element
45
COS/SIN Measurement (ER/XR-Relay Type)
45
AR Parameter
45
Number of AR Shots
45
Fault Time (Tf)
45
Dead Time (Td)
45
Close Impulse Time (Tci)
46
Reclaim Time (Tr)
46
Fault Time Activation
46
Control Functions
47
Block/Trip-Time
47
Time Delay for Ext. Trip
47
Dead Time for Trip/Restore
47
CB Failure Protection
48
Release of the Pickup Relay for CB Failure Protection
48
Interface Parameters
49
Adjustment of the Slave-Address (RS)
49
Adjustment of the Baud-Rate
49
Adjustment of the Parity
49
Using Communication Port RS232 or RS485
49
Fault Recorder (FR)
50
Fault Recorder
50
Number of Fault Recordings
51
Adjustment of the Trigger Event
51
Pre-Trigger Time (T_Pre)
51
Setting of the Clock
52
Additional Functions
52
Blocking the Protection Functions
52
Assignment of the Output Relays
53
Assignment of the AR Functions
56
Function Assignment of the Digital Inputs
58
Description of the Digital Input Function
58
Measuring Value and Fault Indications
59
Measuring Value Indications
59
Units of the Measuring Values Displayed
60
Indication of Fault Data
61
Fault Memory
62
Reset
63
Erasure of the Fault Memory
63
7 Notes on Relay Tests and Commissioning
64
Connection of the Auxiliary Voltage
64
Testing of Output Relays and Leds
64
Secondary Injection Test
65
Test Equipment
65
Example of Test Circuit for MRIK3-C Relays Without Directional Feature
66
Checking the Input Circuits and Measured Values
66
Checking the Operating and Resetting Values of the Relay
67
Checking the Relay Operating Time
67
Checking the High Set Element of the Relay
67
Test Circuit for MRIK3 Relay with Earth-Current Directional Recognition (ER/XR Models)
68
Checking the Auto Reclosing Function
69
Checking the Circuit Breaker Position
69
Checking the AR Blocking Function
70
Checking the External Blocking and Reset Functions
70
Testing the External Blocking with Block/Trip Function
70
Test of the CB Failure Protection
71
Primary Test
71
Maintenance
71
8 Technical Data
72
Measuring Input
72
Common Data
72
Setting Ranges and Steps
73
System Parameter
73
Time Overcurrent Protection (I-Type)
74
Earth Fault Protection (E - Type)
74
Earth Fault Protection (ER/XR-Type)
74
AR Parameter
75
Control Function
76
Interface Parameter
76
Parameter for the Fault Recorder
76
Tripping Characteristics
77
Inverse Time Overcurrent Protection Relay
77
Determination of Earth Fault Direction (MRIK3-ER/XR)
77
Tripping Characteristics
78
Output Relays
81
Advertisement
Advertisement
Related Products
Woodward highprotec MRI4
Woodward MRI3
Woodward MRI3-ITE
Woodward MRI3-ITER
Woodward MRIK3
Woodward MRS1
Woodward MRG3-I
Woodward MRG3-IER
Woodward MRG3-M
Woodward MRR1
Woodward Categories
Controller
Control Unit
Relays
Control Systems
Industrial Equipment