Sign In
Upload
Manuals
Brands
Woodward Manuals
Circuit breakers
LS-5 Series
Woodward LS-5 Series Manuals
Manuals and User Guides for Woodward LS-5 Series. We have
1
Woodward LS-5 Series manual available for free PDF download: User Manual
Woodward LS-5 Series User Manual (125 pages)
Circuit Breaker Control
Brand:
Woodward
| Category:
Circuit breakers
| Size: 3 MB
Table of Contents
Table of Contents
3
Chapter 1 General Information
9
Document Overview
9
Table 1-1: Manual - Overview
9
Chapter 2 Installation
10
Electrostatic Discharge Awareness
10
Marine Usage
11
Application
11
Housing Type
12
Plastic Housing
13
Figure 2-1: Housing - Panel-Board Cutout
13
Table 2-1: Plastic Housing - Panel Cutout
13
Figure 2-2: Plastic Housing LS-521 V2 - Dimensions
14
Figure 2-3: Plastic Housing - Drill Plan
16
Wiring Diagram
17
Figure 2-4: LS-521 V2 (Option K12) - Wiring Diagram
17
Connections
18
Table 2-2: Conversion Chart - Wire Size
18
Power Supply
19
Figure 2-5: Power Supply
19
Figure 2-6: Power Supply - Crank Waveform at Maximum Load
19
Table 2-3: Power Supply - Terminal Assignment
19
Voltage Measuring
20
Voltage Measuring: System a
20
Figure 2-7: Voltage Measuring - System a
20
Table 2-4: Voltage Measuring - Terminal Assignment - System a Voltage
20
Figure 2-8: Voltage Measuring - System a Windings, 3Ph 4W OD
21
Figure 2-9: Voltage Measuring - System a Measuring Inputs, 3Ph 4W OD
21
Table 2-5: Voltage Measuring - Terminal Assignment - System A, 3Ph 4W OD
21
Figure 2-10: Voltage Measuring - System a Windings, 3Ph 4W
22
Figure 2-11: Voltage Measuring - System a Measuring Inputs, 3Ph 4W
22
Table 2-6: Voltage Measuring - Terminal Assignment - System A, 3Ph 4W
22
Figure 2-12: Voltage Measuring - System a Windings, 3Ph 3W
23
Figure 2-13: Voltage Measuring - System a Measuring Inputs, 3Ph 3W
23
Table 2-7: Voltage Measuring - Terminal Assignment - System A, 3Ph 3W
23
Figure 2-14: Voltage Measuring - System a Windings, 1Ph 3W
24
Figure 2-15: Voltage Measuring - System a Measuring Inputs, 1Ph 3W
24
Table 2-8: Voltage Measuring - Terminal Assignment - System A, 1Ph 3W
24
Figure 2-16: Voltage Measuring - System a Windings, 1Ph 2W (Phase-Neutral)
25
Figure 2-17: Voltage Measuring - System a Measuring Inputs, 1Ph 2W (Phase-Neutral)
25
Table 2-9: Voltage Measuring - Terminal Assignment - System A, 1Ph 2W (Phase-Neutral)
25
Figure 2-18: Voltage Measuring - System a Windings, 1Ph 2W (Phase-Phase)
26
Figure 2-19: Voltage Measuring - System a Measuring Inputs, 1Ph 2W (Phase-Phase)
26
Table 2-10: Voltage Measuring - Terminal Assignment - System A, 1Ph 2W (Phase-Phase)
26
Voltage Measuring: System B
27
Figure 2-20: Voltage Measuring - System B
27
Table 2-11: Voltage Measuring - Terminal Assignment - System B Voltage
27
Figure 2-21: Voltage Measuring - System B PT Windings, 3Ph 4W
28
Figure 2-22: Voltage Measuring - System B Measuring Inputs, 3Ph 4W
28
Table 2-12: Voltage Measuring - Terminal Assignment - System B, 3Ph 4W
28
Figure 2-23: Voltage Measuring - System B PT Windings, 3Ph 3W
29
Figure 2-24: Voltage Measuring - System B Measuring Inputs, 3Ph 3W
29
Table 2-13: Voltage Measuring - Terminal Assignment - System B, 3Ph 3W
29
Figure 2-25: Voltage Measuring - System B PT Windings, 1Ph 3W
30
Figure 2-26: Voltage Measuring - Mains System B Measuring Inputs, 1Ph 3W
30
Table 2-14: Voltage Measuring - Terminal Assignment - System B, 1Ph 3W
30
Figure 2-27: Voltage Measuring - System B PT Windings, 1Ph 2W (Phase-Neutral)
31
Figure 2-28: Voltage Measuring - System B Measuring Inputs, 1Ph 2W (Phase-Neutral)
31
Table 2-15: Voltage Measuring - Terminal Assignment - System B, 1Ph 2W (Phase-Neutral)
31
Figure 2-29: Voltage Measuring - System B PT Windings, 1Ph 2W (Phase-Phase)
32
Figure 2-30: Voltage Measuring - System B Measuring Inputs, 1Ph 2W (Phase-Phase)
32
Table 2-16: Voltage Measuring - Terminal Assignment - System B, 1Ph 2W (Phase-Phase)
32
Current Measuring
33
System a Current
33
Figure 2-31: Current Measuring - System a
33
Table 2-17: Current Measuring - Terminal Assignment - System a Current
33
Figure 2-32: Current Measuring - System A, L1 L2 L3
34
Figure 2-33: Current Measuring - System A, L1 L2 L3
34
Figure 2-34: Current Measuring - System A, Phase Lx
34
Table 2-18: Current Measuring - Terminal Assignment - System A, Phase Lx
34
Power Measuring
35
Power Factor Definition
35
Figure 2-35: Power Measuring - Direction of Power
35
Discrete Inputs
37
Discrete Inputs: Signal Polarity
37
Figure 2-36: Discrete Inputs - Alarm/Control Input - Positive Signal
37
Figure 2-37: Discrete Inputs - Alarm/Control Input - Negative Signal
37
Table 2-19: Discrete Input - Terminal Assignment
37
Default Value / Configurable Via Logicsmanager
37
Discrete Inputs: Operation Logic
38
Figure 2-38: Discrete Inputs - Alarm/Control Inputs - Operation Logic
38
Relay Outputs (Logicsmanager)
39
Figure 2-39: Relay Outputs
39
Table 2-20: Relay Outputs - Terminal Assignment
39
Interfaces
41
Service Port
41
Figure 2-40: Service Port Connector (RJ-45)
41
Figure 2-41: DPC-USB Wiring - Schematic
41
Figure 2-42: DPC-RS-232 Wiring - Schematic
42
CAN Bus Interface
43
Figure 2-43: Interfaces - CAN Bus - Termination
43
Table 2-21: CAN Bus - Pin Assignment
43
Bus Shielding
44
Figure 2-44: Interfaces - Shielding (External RC Element)
44
Table 2-22: Maximum CAN Bus Length
44
Table 2-23: Bus Shielding
44
Chapter 3 Configuration
45
Configuration Via Front Panel
45
Configuration Via PC
46
Install Toolkit Configuration and Visualization Software
46
Install Toolkit Software
46
Install Toolkit Configuration Files
47
Starting Toolkit Software
48
Configure Toolkit Software
49
Connect Toolkit and the LS-5 Unit
50
View LS-5 Data with Toolkit
52
Figure 3-1: Toolkit - Visualization Screen
52
Figure 3-2: Toolkit - Analog Value Trending Screen
52
Configure the LS-5 with Toolkit
53
Figure 3-3: Toolkit - Configuration Screen
53
Parameters
54
Language / Clock Configuration
54
Display Configuration
56
Figure 3-4: Configure Display
56
Table 3-1: Daylight Saving Time - Configuration Example
56
Table 3-2: Daylight Saving Time - Examplary Dates
56
Enter Password
57
System Management
58
System Management: Password System
59
Configuration
60
Table 3-3: Calculation of the Phase Angle Deviation
63
Table 3-4: Discrete Inputs - Parameter Ids
66
Table 3-5: Relay Outputs - Assignment
67
Table 3-6: Discrete Outputs - Parameter Ids
67
Chapter 4 Operation
82
Figure 4-1: Front Panel and Display
82
Table 4-1: Measuring Values
84
Screen Structure
85
Figure 4-2: Screen Structure
85
Navigation
86
Alarm List
86
Parameter
86
Main Menu
88
Display Messages
92
Status Messages
92
Alarm Messages
92
Table 4-2: Message Ids for Discrete Inputs
92
Chapter 5 Interface
93
Interfaces Overview
93
CAN Interface
93
Figure 5-1: Interface Ovierview
93
Figure 5-2: CAN Interface 1
93
Serial Interfaces
94
Figure 5-3: RS-232 Interface
94
Protocols Overview
95
Canopen
95
Chapter 6 Technical Data
96
Environmental Data
99
Accuracy
100
Appendix A. Useful Information
101
Connecting 24 V Relays
101
Figure 6-1: Interference Suppressing Circuit - Connection
101
Table 6-1: Interference Suppressing Circuit for Relays
102
Appendix B. Miscellaneous
103
Alarm Classes
103
Appendix C. Logicsmanager
104
Figure 6-2: Logicsmanager - Function Overview
104
Table 6-2: Logicsmanager - Command Overview
105
Logical Symbols
106
Figure 6-3: Logicsmanager - Display in Toolkit
106
Figure 6-4: Logicsmanager - Display on LCD Screen
106
Table 6-3: Logicsmanager - Logical Symbols
106
Logical Outputs
107
Logical Outputs: Internal Functions
107
Logical Outputs: Relay Outputs
107
Table 6-4: Relay Outputs - Terminal Assignment
107
Logical Command Variables
108
Logical Command Variables: Group 00: Flags Condition 1
109
Logical Command Variables: Group 01: Alarm System
110
Logical Command Variables: Group 02: Systems Condition
111
Logical Command Variables: Group 04: Applications Condition
112
Logical Command Variables: Group 05: Device Related Alarms
113
Logical Command Variables: Group 06: System B Related Alarms
113
Logical Command Variables: Group 07: System a Related Alarms
113
Logical Command Variables: Group 08: System Related Alarms
113
Logical Command Variables: Group 09: Discrete Inputs
114
Logical Command Variables: Group 13: Discrete Outputs
114
Appendix D. Data Protocols
115
Canopen
115
Appendix E. Additional Information
118
Synchronization of System a and System B
118
Table 6-5: Synchronization of Two Systems
118
Appendix F. Event History
119
Resetting the Event History
119
Table 6-6: Event History - Event List
121
Service Options
122
Product Service Options
122
Returning Equipment for Repair
122
Packing a Control
123
Return Authorization Number RAN
123
Replacement Parts
123
Engineering Services
123
How to Contact Woodward
123
Technical Assistance
124
Advertisement
Advertisement
Related Products
Woodward LS-521
Woodward easYgen LS-6XT
Woodward easYgen LS-612XT-P1
Woodward L-Series
Woodward LS 4
Woodward LS-5 v2 Series
Woodward LS-522
Woodward LS-512
Woodward LSOV25
Woodward Categories
Controller
Control Unit
Relays
Control Systems
Industrial Equipment
More Woodward Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL