Vertiv NetSure 801NLDB System Application Manual (110 pages)
48 VDC Power System
Brand:
Vertiv
| Category:
Power Supply
| Size: 5.68 MB
Table of Contents
System Overview
1
Table of Contents
6
Main Components Illustrations
8
582140001 Power Bays
8
582140001 Distribution Bays
9
582140001 Power Bays Monitor and Control Diagram
10
582140001 Distribution Bays Monitor and Control Diagram
10
List Descriptions
11
List 0A: 380/480VAC Plant Input Voltage
11
List 0B: 208VAC Plant Input Voltage
11
List 04: Primary Power Bay (2 AC Input Feeds)
11
List 05: Primary Power Bay (12 or 24 AC Input Feeds)
12
List 06: Primary Power Bay (6 AC Input Feeds)
12
List 12: Secondary Power Bay (2 AC Input Feeds)
13
List 13: Secondary Power Bay (12 or 24 AC Input Feeds)
14
List 14: Secondary Power Bay (6 AC Input Feeds)
14
List 16: Distribution Bay
15
List 21: Rectifier Module, 208V Input
15
List 22: Rectifier Module, 380/480V Input
16
List 24: Rectifier Module, 380/480V Input
16
List 50: Optional LMS Main CPU Circuit Card (Primary Power Bay)
16
List 63: Optional LMS Expansion CPU Circuit Card (Secondary Power Bays)
16
List 64: Interface Kit to a Spec. No. 582121900 Power System Equipped with a DGU
16
List 65: Interface Kit to a Spec. No. 582121901 Power System Equipped with an LMS1000
17
List 66: Interface Kit to a Vortex Power System Without a DGU or LMS1000
17
List 67: Interface Kit to a Model 1231H Legacy Power System with 1-8 Rectifiers
17
List 70: Additional MCA Six (6) Output Form-C Relay Circuit Card
18
List 71: MCA I/O Circuit Card P/N 524550
18
List 0C: 24 Position Bullet-Nose Circuit Breaker/Fuse Panel
19
Accessory Descriptions
20
Seismic Anchor Kit, P/N 545387
20
Seismic Anchor Isolation Kit, P/N 545388
20
Main Battery Termination Bars (Mbtb's)
20
Distribution Device and Load Lug Locations
20
Distribution Devices
24
218 Circuit Breaker Assemblies
24
TPL Fuses and Fuseholder Assemblies
28
Bullet Nose-Type Circuit Breakers and Bullet Nose-Type Fuseholders E/W TLS/TPS Fuses
31
Optional Bullet Nose-Type 10-Position GMT Fuse Module for List C
36
Replacement Alarm, Reference, and Control Fuses
37
Fuseblock Located in Bay's Left Center
37
Input and Alarm Fuse on Optional Bullet Nose-Type 10-Position GMT Fuse Module, P/N 509128
38
Wiring Components
39
Load Distribution Wire Sizes and Lugs Selection (Distribution Bay)
39
Power Bay DC Output Cable Sizes and Lugs Selection
43
Distribution Bay DC Input Cable Sizes and Lugs Selection
45
Power Bay Frame Grounding Wire Sizes and Lugs Selection
47
Distribution Bay Frame Grounding Wire Sizes and Lugs Selection
48
AC Input (12 or 24 AC Input Feeds) Wire and Conduit Sizes, Branch Circuit Protection, and Lugs Selection Lists 5 and 13
49
AC Input (6 AC Input Feeds) Wire and Conduit Sizes, Branch Circuit Protection, and Lugs Selection Lists 6 and 14
52
AC Input (2 AC Input Feeds) Wire and Conduit Sizes, Branch Circuit Protection, and Lugs Selection Lists 4 and 12
58
External Alarm, Reference, and Control Wire Sizes - Power Bays
61
Optional Battery Charge Temperature Compensation Probe for Digital Compensation
62
Replacement/Additional MCA Network Cable
63
Replacement/Additional LMS Network Cable
63
Replacement Modules and Circuit Cards
64
Specifications
65
System
65
DC Operating Voltage
65
Environmental Ratings
65
Compliance Information
66
Local Controls and Indicators
66
Distribution Bay
66
DC Ratings
66
Rectifier Module (Model R48-5800, Spec. No. 1R485800)
67
DC Output Ratings
67
AC Input Ratings
69
Environmental Ratings
70
Standard Features
72
Rectifier Module (Model R48-5800L, Spec. No. 1R485800L)
76
DC Output Ratings
76
AC Input Ratings
78
Environmental Ratings
79
Standard Features
81
Rectifier Module (Model R48-5800E Spec. No. 1R485800E)
85
DC Output Ratings
85
AC Input Ratings
87
Environmental Ratings
88
Standard Features
90
Mca
93
Standard Features
93
Optional LMS Monitoring System
105
Mechanical Specifications
106
Floor Hole Drilling Pattern Dimensions - Power Bays
106
Floor Hole Drilling Pattern Dimensions - Distribution Bays
106
Overall Dimensions - Primary and Secondary Power Bays
107
Overall Dimensions - Distribution Bays
108
Overall Dimensions - Optional Battery Charge Digital Temperature Compensation Probes P/N 107021 (25 Feet) and P/N 106824 (100 Feet)
109
Related Documentation
110
Advertisement
Vertiv NetSure 801NLDB User Manual (176 pages)
Brand:
Vertiv
| Category:
Power Supply
| Size: 23.01 MB
Advertisement
Related Products
Vertiv NetSure 801DB NVGB
Vertiv NetSure 801 CA7
Vertiv NetSure 801 CAA Series
Vertiv NetSure 801 AG1
Vertiv NetSure 801NLEB
Vertiv NetSure 801NL-B
Vertiv 802NLEB
Vertiv 802NLDB
Vertiv 802NL-B
Vertiv NetSure 802
Vertiv Categories
UPS
Power Supply
Switch
Power distribution unit
Air Conditioner
More Vertiv Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL