Sign In
Upload
Manuals
Brands
Vertiv Manuals
Power Supply
NetSure 801DB NVGB
Vertiv NetSure 801DB NVGB Manuals
Manuals and User Guides for Vertiv NetSure 801DB NVGB. We have
1
Vertiv NetSure 801DB NVGB manual available for free PDF download: System Application Manual
Vertiv NetSure 801DB NVGB System Application Manual (75 pages)
Brand:
Vertiv
| Category:
Power Supply
| Size: 6.74 MB
Table of Contents
System Overview
1
Table of Contents
3
Main Components Illustrations
5
Eight Panel Bay
5
Six Panel Bay
7
List Descriptions
9
List Numbers
9
List 106: Common Equipment, 6-Panel Bay, W/ Advanced Metering
9
List 206: Common Equipment, 6-Panel Bay, W/ Advanced Metering
10
List 108: Common Equipment, 8-Panel Bay, W/ Advanced Metering
11
List 208: Common Equipment, 8-Panel Bay, W/ Advanced Metering
12
List 110: Distribution Panel, 8-Panel Bay
13
List 115: Distribution Panel, 8-Panel Bay
13
List 116: Optional Internal Ground/Return Bar, 8-Panel Bay (Full Bay Length)
14
List 117: Optional Internal Ground/Return Bar, 8-Panel Bay (Panel Length)
14
List 118: Blank Distribution Panel Cover, 8-Panel Bay
15
List 120: Distribution Panel, 6-Panel Bay
15
List 125: Distribution Panel, 6-Panel Bay
16
List 126: Optional Internal Ground/Return Bar, 6-Panel Bay (Full Bay Length)
16
List 127: Optional Internal Ground/Return Bar, 6-Panel Bay (Panel Length)
17
List 128: Blank Distributional Panel Cover, 6-Panel Bay
17
List 130: Distribution Panel Paralleling Bar
17
List 139: Optional Internal Ground/Return Bar Paralleling Kit, 8-Panel Bay (Panel Length)
18
List 143: Bay Input Feed and Shunt Assembly (4 Cables, 25 MV. Shunts)
18
List 144: Bay Input Feed and Shunt Assembly (2 Cables, 25 MV. Shunts)
18
List 145: Bay Input Feed and Shunt Assembly (2 Cables, 50 MV. Shunts)
19
List 147: Bay Input Feed and Shunt Assembly (4 Cables, 50 MV. Shunts)
19
List 148: 2400A Ground/Return Input Assembly, with Optional Bonding Strap
20
List 150: Optional Capacitor Precharge Assembly
20
List 151: Dressing Bar
21
List 251: Dressing Bar
21
List 153: Load Distribution Cable Management Kit
21
List 253: Load Distribution Cable Management Kit
22
List 166: Meter Panel Field Upgrade Retrofit Kit
22
List 167: Pre-Installed Load Lug-Mounting Hardware
22
List 168: Meter Panel Field Upgrade Retrofit Kit
23
List 170: Assembly, Ethernet
23
For Manufactured Discontinued Bays (Model 1293V3)
24
Accessory Descriptions
26
Load Lug Hardware Kits
26
Side by Side Busbar Link Kit for Use with List 110 and List 120, P/N 556103
26
Side by Side Busbar Link Kit for Use with List 115 and List 125, P/N 557256
26
Revision BK, September
27
Right Angle Lug Adaptor Kits, P/Ns 556377 and 556378
28
Revision BK, September
28
External Return/Ground Bar Assemblies
29
Seismic Anchor Kit, P/N 545387
30
Transient Voltage Surge Suppressor (TVSS) Device
30
Distribution Devices and Lug Selection
31
TLS/TPS Fuses/Fuseblocks, TPL Fuses/Fuseblocks, and Lug Selection for Lists 110 and 120
31
115 And 125
35
Box Framework Extensions
41
One (1) Foot Box Framework Extension
41
Two (2) Foot Box Framework Extension
41
Four and One-Half (4-1/2) Foot Box Framework Extension
41
Wiring Notes
42
Bay Frame Grounding Wire Sizes and Lugs Selection
42
External Alarm Wiring-List 105 and 107 Bays
42
External Alarm and Control Wiring-List 106, 206, 108 and 208 Bays
42
Load Distribution Wire Sizes Selection
43
DC Input Cable Sizes and Lugs Selection
47
Wiring Illustrations
48
Overall Installer's Connections
48
Bay Frame Grounding Connection
49
External Alarm and Meter/Alarm Card Input Connections
50
Load Distribution Connections-Lists 106, 108, 206, 208
55
DC Input Connections
61
Replacement Alarm, Reference, and Control Fuses, List 105 and 107 Bays
64
Fuseblock Located in Bay's Top Center
64
Replacement Alarm, Reference, and Control Fuses, List 106 and 108 Bays
64
Fuses Located on Auxiliary Fuse Card at Top of Bay
64
Replacement Circuit Cards, List 105 and 107 Bays
65
Replacement Circuit Cards, List 106, 108, 206, and 208 Bays
65
Specifications
66
DC Operating Voltage
66
1.2 Environmental Ratings
66
1.3 Compliance Information
66
1.4 Output Ratings
66
1.5 Standard Features-Lists 106 and 108
66
Mechanical Specifications (List 106 and 108)
68
Floor Hole Drilling Pattern Dimensions
68
Mechanical Specifications (List 206 and 208)
69
Floor Hole Drilling Pattern Dimensions
69
Dimensions, List 108: 8-Bus Bay
70
Dimensions, List 208: 8-Bus Bay
71
Dimensions, List 106: 6-Bus Bay
72
Dimensions, List 206: 6-Bus Bay
73
Related Documentation
74
Revision Record
75
Advertisement
Advertisement
Related Products
Vertiv NetSure 801 CA7
Vertiv NetSure 801 CAA Series
Vertiv 802NLEB
Vertiv 802NLDB
Vertiv 802NL-B
Vertiv NetSure 801 AG1
Vertiv NetSure 801NLDB
Vertiv NetSure 801NLEB
Vertiv NetSure 801NL-B
Vertiv NetSure 802
Vertiv Categories
UPS
Power Supply
Switch
Power distribution unit
Air Conditioner
More Vertiv Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL