Sign In
Upload
Manuals
Brands
Valleylab Manuals
Medical Equipment
Force FX-C
Valleylab Force FX-C Manuals
Manuals and User Guides for Valleylab Force FX-C. We have
1
Valleylab Force FX-C manual available for free PDF download: Service Manual
Valleylab Force FX-C Service Manual (214 pages)
Electrosurgical Generator with Instant Response Technology
Brand:
Valleylab
| Category:
Medical Equipment
| Size: 9 MB
Table of Contents
Conventions Used in this Guide
5
Table of Contents
6
List of Figures
12
Section 1. Introduction
15
General Description 1·2
16
List of Components 1·3
17
Service Personnel Safety 1·3
17
General 1·3
17
Fire/Explosion Hazards 1·4
18
Electric Shock Hazards
19
Servicing
19
Calibration 1·6
20
Cleaning 1·6
20
Section 2. Controls, Indicators, and Receptacles
21
Front Panel 2·2
22
Bipolar Controls 2·3
23
Bipolar Instrument Receptacle 2·4
24
Monopolar Cut Controls 2·5
25
Monopolar Coag Controls 2·6
26
Monopolar Instrument Receptacles 2·7
27
REM Alarm Indicator 2·8
28
Rear Panel 2·9
29
Footswitch Receptacles 2·10
30
Monopolar Footswitch Receptacles 2·10
30
Bipolar Footswitch Receptacle 2·10
30
Power Entry Module 2·11
31
Activation Tone Volume Control 2·11
31
Option Panel 2·12
32
Section 3. Technical Specifications
33
Performance Characteristics 3·1
33
General
33
Dimensions and Weight 3·2
34
Operating Parameters 3·2
34
Transport and Storage 3·2
34
Duty Cycle
35
Internal Memory 3·3
35
Audio Volume
35
REM Contact Quality Monitor
36
Serial Port
37
RF Activation Port
37
Expansion Port
37
Low Frequency (50-60 Hz) Leakage Current
37
High Frequency (RF) Leakage Current
38
Input Power
38
Standards and IEC Classifications
39
Class I Equipment(IEC 601-1)
39
Type CF Equipment (IEC 601-1)/Defibriliator Proof
39
Drip Proof (IEC 601-2-2)
39
Electromagnetic Interference
40
Electromagnetic Compatibility (IEC 601-1-2 and IEC 601-2-2)
40
Voltage Transients (Emergency Generator Mains Transfer)
40
Output Characteristics
41
Maximum Output for Bipolar and Monopolar Modes
41
Maximum Output for Ultrasonic Electrosurgery
41
Available Power Settings in Watts
42
Output Waveforms
43
Output Power Vs. Resistance Graphs
45
Bipolar Graphs
45
Monopolar Cut Graphs 3·15
47
Monopolar Coag Graphs
48
Functional Overview
53
Instant Response Technology 4·3
53
Ultrasonic Electrosurgery
53
Simultaneous Coag 4·3
53
REM Contact Quality Monitoring System
54
Control Board
55
Microcontrollers
55
Main Microcontroller
55
Feedback Microcontroller
56
Shared RAM
57
Keyboard Interface and Activation Inputs
57
Power Supply Supervisor Circuit
58
AID and D/A Conversion
58
Waveform Generation (T_ON ASIC)
58
T_ON Average Check
59
Audio Alarm
59
Serial Interface
59
Dosage Error Algorithm
60
Instant Response Algorithm
61
Front Panel
62
Membrane Keyboard
62
Power Switch
62
REM Connector/Switch
62
CEM Mechanism Switch
62
Display Board
63
RF Indicator Lamps
63
REM Indicators
63
LED and Seven-Segment Display Drivers
63
CEM Switch Circuit
64
Mode Selection and Power Control Switches
64
Footswitch Board
65
Footswitch Decode Circuit
65
Audio Circuit
66
Power Supply/Rf Board
67
Power Supply/Rf Board Interfaces
68
High Voltage Power Supply
68
Low Voltage Power Supply
71
RF Output Stage
71
Spark Control Circuit
74
RF Leakage Reduction Circuit
75
REM Circuit
75
Isobloc Circuit
75
Temperature Sense Circuits
76
Section 5. Setup, Tests, and Adjustments
79
Setting up the Generator
80
Connections for Bipolar or Macrobipolar Surgery
82
Setting the Bipolar Output
83
Connections for Monopolar Surgery
84
Selecting Cut and Coag Modes
86
Simultaneous Coag
86
Using Two Generators Simultaneously
87
Connecting the CUSA Handpiece with CEM Nosecone
88
Setting the Output Power
89
Simultaneous Coag with a CUSA System
89
Changing the Mode
89
Changing the Power Setting
89
Activating the Surgical Instrument
90
Periodic Safety Check
91
Recommended Test Equipment
91
Inspecting the Generator and Accessories
92
Inspecting the Internal Components
93
Testing the Generator
94
Verifying REM Function
95
Confirming Outputs
95
Check the Output for the Cut Modes
97
Check the Output for the Coag Modes
98
Checking Low Frequency Leakage Current
99
Checking High Frequency Leakage Current
101
Calibrating the Force FX-C Generator
102
Preparing for Calibration
103
Entering Calibration Mode
103
Exiting Calibration Mode
104
Verify the Force FX-C Generator Data
104
Adjust the Calendar
105
Adjust the Clock
106
Check and Adjust the REM Oscillator Frequency and Impedance
107
Check and Adjust the Voltage Sense Gain
110
Check and Adjust the Reactance Gain
112
Check and Adjust the ECON Factor
114
Using the RS-232 Serial Port
118
Enter the Commands
119
Disconnect the Computer from the Generator
122
Section 6. Troubleshooting
123
Inspecting the Generator
123
Inspecting the Receptacles
124
Inspecting the Internal Components
125
Correcting Malfunctions
126
Responding to System Alarms
132
Correcting IC U3 Malfunctions
142
Correcting IC U6 Malfunctions
144
Correcting T
146
Correcting Battery-Backed RAM Malfunctions
148
Section 7. Replacement Procedures
151
Interconnect Diagram
152
Battery Replacement
153
Control Board Replacement
154
Display Board Replacement 7·5
155
Install the Display Board
156
Display Board Seven-Segment LED Replacement
157
Fan Replacement
158
Footswitch Board Replacement
158
Front Panel Replacement
159
Remove the Front Panel Assembly
159
Front Panel REM Module Replacement
161
Front Panel Power Switch Replacement
162
Fuse Replacement
163
Replacing Fuses in the Fuse Drawer 7·13
163
Replacing the Fuse on the Power Supply/Rf Board
164
Left Front Heat Sink and Component Replacement 7·15
165
Remove the Left Front Heat Sink
165
Replace Left Front Heat Sink Components
166
Install the Left Front Heat Sink 7·16
166
Left Rear Heat Sink and Component Replacement
167
Replace Left Rear Heat Sink Components
168
Install the Left Rear Heat Sink
169
Right Heat Sink and Component Replacement 7·20
170
Remove the Right Heat Sink
170
Replace Right Heat Sink Components
171
Install the Right Heat Sink 7·22
171
Low Voltage Power Supply Replacement 7·23
173
Install the Low Voltage Power Supply
174
Power Entry Module Replacement
175
Install the Power Entry Module
176
Power Supply/Rf Board Replacement
177
Remove the Power Supply/Rf Board Assembly
177
Remove Components from the Old Board
178
Install Components on the New Board
179
Install the Power Supply/Rf Board Assembly
180
Section 8. Repair Policy and Procedures
181
Responsibility of the Manufacturer
181
Returning the Generator for Service
182
Obtain a Return Authorization Number
182
Clean the Generator
182
Ship the Generator
183
Returning Circuit Boards
183
Service Centers
184
Section 9. Service Parts
185
Ordering Replacement Parts
185
Generator Assembly
186
Parts List
188
Front Panel Assembly
190
Parts List
192
Control Board Components
193
Display Board Components
194
Footswitch Board Components
195
Power Supply/Rf Board Assembly
198
Parts List
200
Power Supply/Rf Board Components
203
Appendix A. Warranty
213
Advertisement
Advertisement
Related Products
Valleylab ForceTriad
Valleylab Force 2
Valleylab Force 30
Valleylab Force 40
Valleylab FORCE 4
Valleylab Force FX-8C
Valleylab Force EZ - C Series
Valleylab Force 2-2 PCH
Valleylab Force 2-8 PCH
Valleylab Force2
Valleylab Categories
Medical Equipment
Portable Generator
Inverter
More Valleylab Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL