Sign In
Upload
Manuals
Brands
Vaisala Manuals
Control Unit
HUMICAP HMM213
Vaisala HUMICAP HMM213 Temperature Module Manuals
Manuals and User Guides for Vaisala HUMICAP HMM213 Temperature Module. We have
1
Vaisala HUMICAP HMM213 Temperature Module manual available for free PDF download: User Manual
Vaisala HUMICAP HMM213 User Manual (52 pages)
Humidity and Temperature Module
Brand:
Vaisala
| Category:
Control Unit
| Size: 0 MB
Table of Contents
Table of Contents
3
Vaisala
3
Vaisala
5
Chapter 1 General Information
9
About this Manual
9
Contents of this Manual
9
Version Information
10
Related Manuals
10
General Safety Considerations
10
Table 1 Manual Revisions
10
Table 2 Related Manuals
10
Feedback
11
Product Related Safety Precautions
11
ESD Protection
11
Recycling
12
Regulatory Compliances
12
Table 3 Emission Tests
12
Table 4 Immunity Tests
12
Patent Notice
13
Trademarks
13
Warranty
13
Chapter 2 Product Overview
15
Introduction to HMM213
15
Chapter 3
17
To be Noted When Measuring Humidity
17
Figure 1 Measurement Error at 100 %RH When the Temperature Difference between the Ambient Air and the Sensor Is 1 °C
18
Chapter 4 Installation
19
Selecting Location
19
Electrical Connections
19
Figure 2 Electrical Connections
19
Dimensions
20
Serial Bus Settings
20
Figure 3 Dimensions in MM (Inches)
20
Chapter 5 Serial Commands
21
Output Via the Serial Bus
21
R Starting the Measurement Output
21
S Stopping the Measurement Output
21
SEND Outputting a Reading Once
22
INTV Setting the Output Interval for the RUN State
22
SERI Serial Bus Settings
23
ADDR Setting the Device Address
23
UNIT Selecting the Output Units
24
VERS Displaying Software Version
24
RESET Resetting the Transmitter
24
Table 5 Output Units
24
Operating Via the Serial Bus
25
SMODE Setting the Serial Interface
25
Open & Close
25
Setting the Output Format
26
MCR Setting the Carriage Return On/Off
26
MDEC Selecting a Decimal Separator
26
MFLD Selecting a Field Separator
27
MLF Setting the Line Feed On/Off
27
MSPC Setting Spaces On/Off
28
MSYMB Setting Variable Symbols On/Off
28
MUNIT Setting Variable Units On/Off
29
Chapter 6 Calibration
31
Humidity Calibration
32
Humidity Calibration with Serial Commands
32
Two-Point Calibration
32
One Point Calibration
33
Gain Calibration
33
With the Hand-Held Humidity and Temperature Meter HM70 or HMI41 Indicator and Calibration Cable
34
Figure 4 Calibration Connector for the HM70 or HMI41
34
Calibration Table
36
Temperature Calibration
36
CT Temperature Calibration of the Warmed Humidity Sensor Head
36
Two Point Calibration
36
Table 6 Greenspan's Calibration Table with Output Values According to the Chosen Scale
36
One Point Calibration
37
Gain Calibration
37
CT Temperature Calibration of the Additional Sensor Head
38
Two Point Calibration
38
One Point Calibration
39
Gain Calibration
39
Chapter 7
41
Chemical Purge Option
41
Figure 5 Decrease of the Sensor Gain Due to an Interfering Chemical and the Effect of the Chemical Purge Process
41
Chapter 8 Maintenance
43
Replacing the HUMICAP
43
180R Sensor and the Filter
43
Replacing Consumables
43
Parts List for Consumables
43
Table 7 Available Spare Parts
43
Chapter 9 Troubleshooting
45
Troubleshooting Procedure
45
Technical Support
45
Return Instructions
46
Vaisala Service Centers
47
Technical Data
49
Figure 6 Dewpoint Temperature
49
Table 8 Relative Humidity Specifications
49
Options
50
Table 9 General Specifications
50
Table 10 Operating Voltage Specifications
50
Table 11 Modules, Sensor Heads and Outputs
50
Table 12 Cable Lengths for Sensor Heads
51
Table 13 Chemical Purge
51
Advertisement
Advertisement
Related Products
Vaisala HUMICAP HMM100
Vaisala HUMICAP HMM170
Vaisala HUMICAP HMM105
Vaisala HUMICAP HMM212
Vaisala HUMICAP HM44
Vaisala HUMICAP HMT363
Vaisala HMP265
Vaisala HMP110REF
Vaisala HUMICAP HMI41
Vaisala HUMICAP HMP155
Vaisala Categories
Transmitter
Measuring Instruments
Accessories
Weather Station
Test Equipment
More Vaisala Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL