Sign In
Upload
Manuals
Brands
Tsuruga Manuals
Test Equipment
8527
Tsuruga 8527 Insulation Tester Manuals
Manuals and User Guides for Tsuruga 8527 Insulation Tester. We have
1
Tsuruga 8527 Insulation Tester manual available for free PDF download: Instruction Manual
Tsuruga 8527 Instruction Manual (112 pages)
Motor Slider Type Withstanding Voltage & Insulation Resistance Tester
Brand:
Tsuruga
| Category:
Test Equipment
| Size: 4 MB
Table of Contents
Table of Contents
4
Preface
6
Initial Setting at the Time of Delivery
6
2 Confirmation Prior to Use
7
Unpacking
7
Cautions for Handling
7
3 Name of Parts and Functions
8
Front Panel
8
Rear Panel
12
Status of Display and Expression in Instruction Manual
13
4 Preparation Prior to Use
14
Zero Adjustment of Output Voltmeter
14
Connection of Protective Ground Terminal
14
Connection with External Control Device
14
Connection of High Voltage Cable
14
Connection of Power Supply Cable
15
Throw in and Shut off of Power Source
15
Before the Test
16
Setting Items in each Mode
18
READY Status
18
Setting Mode of Test Conditions
18
Memory Write-In Mode
18
Memory Read-Out Mode
18
6 Kind of Test and Flow of Setting
19
Kind of Test
19
Flow of Setting
19
7 Operation of Motor Slider
20
Outline of Operation of Motor Slider
20
Manual Operation of Motor Slider
21
Automatic Operation of Motor Slider
21
8 Setting of Test Condition for Withstanding Voltage Test
22
Voltage of Motor Slider
22
Referential Voltage
23
High Limit of Leak Current
25
Low Limit of Leak Current
26
9 Setting of Test Condition for Insulation Resistance Test
30
Test Range of Insulation Resistance Test
30
High Limit of Resistance Value
31
Low Limit of Resistance Value
33
Time of Mask Timer
34
Test Time
35
Discharging Function
37
10 Memory Function
38
Configuration of Memory
38
Memory Write-In
38
Memory Read-Out
39
Voltage Adjustment of Motor Slider by Memory
40
11 Test Procedure (from Start to Judgement Result)
41
W Test (Withstanding Voltage Test)
41
I Test (Insulation Resistance Test)
43
W-I Test (Withstanding Voltage → Insulation Resistance Test)
44
I-W Test (Insulation Resistance → Withstanding Voltage Test)
45
12 Key Lock
46
13 Special Test Mode
47
14 Remote Control
48
Operation by REMOTE Connector
48
Operation by REMOTE Terminal Block
48
Operation by REMOTE/OUT Connector
49
Operation by REAR:MODE Operation
50
Voltage Adjustment of Motor Slider by REMOTE/OUT Connector
51
Priority of each Remote Control
51
15 External Control
52
Control by REMOTE/OUT Connector
52
Arrangement and Function of Connector Pins
52
Interlock Signal
53
Protective Function (PROTECTION)
53
Output Signals and Power Supply for Control
54
16 Status Output
55
Name of STATUS OUTPUT and Condition for Output
55
Specifications of Status Output
55
Setting of Condition for Status Output
56
17 Timing Chart
57
Motor Slider Working
57
From Motor Slider Stoppage to Finish of Test
58
18 Adjustment of Buzzer Sound
59
19 Monitor Output of Voltage
60
20 Error Messages
61
21 Maintenance and Troubles
62
Cleaning
62
Failure Symptom
62
Replacement of Fuse
62
For Long Term Troubles-Less Use
63
22 Specifications
64
Rs-232C Interface for Model 8527 Instruction Manual
70
Specifications
71
2 Connections
72
Connectors and Signals
72
Connection with Host (Reference)
72
3 Explanation of Communication Method
73
Communication Method for Command
73
Basic Format of Read-Out Command
75
Basic Format of Setting and Operation
75
4 Explanation of Command
76
Table of Command
76
Explanation of each Command
77
REMOTE= (Setting of Remote Control)
77
REMOTE? (Read-Out of Setting of Remote Control)
77
KEYLOCK? (Read-Out of Keylock Status)
78
KEYLOCK= (Setting of Keylock)
78
FORMAT= (Setting of Response Format)
79
FORMAT? (Read-Out of Response Format)
79
RESPONSE= (Setting of Response)
80
MODE? (Read-Out of Test Mode)
81
START (Start of Test)
82
RESET (Stop of Test, Judgement Reset)
82
STATUS? (Read-Out of Status)
83
IDNT? (Read-Out of Tester Identification)
84
WLEVEL= (Setting of Referential Voltage of Withstanding Voltage Test)
85
WLEVEL? (Read-Out of Referential Voltage of Withstanding Voltage Test)
85
WTIMER= (Setting of Test Time of Withstanding Voltage Test)
88
WTIMER? (Read-Out of Test Time of Withstanding Voltage Test)
88
IVOLT= (Setting of Test Voltage Range of Insulation Resistance Test)
89
IVOLT? (Read-Out of Test Voltage Range of Insulation Resistance Test)
89
ILOW? (Read-Out of Low Limit of Resistance Value for Insulation Resistance Test)
91
IMASK= (Setting of Mask Time of Insulation Resistance Test)
92
IMASK? (Read-Out of Mask Time of Insulation Resistance Test)
92
ITIMER= (Setting of Test Time of Insulation Resistance Test)
93
ITIMER? (Read-Out of Test Time of Insulation Resistance Test)
93
DISCHARGE= (Setting of Discharge Function of Insulation Resistance Test)
94
DISCHARGE? (Read-Out of Discharge Function of Insulation Resistance Test)
94
DATA? (Lump Read-Out of Test Result)
96
SET: (Setting of Parameters of Test Condition)
97
SET:? (Lump Read-Out of Parameters of Test Condition)
97
MEM no : (Setting of Test Condition to Memory)
99
MEM no :? (Read-Out of Memorized Test Condition)
99
5 Command Which Can Perform a Setup of Slider Voltage
101
6 Error
102
7 Cautions
102
8 Sample Program
103
Advertisement
Advertisement
Related Products
Tsuruga 8507
Tsuruga 8505
Tsuruga 8526
Tsuruga 8528
Tsuruga 8525
Tsuruga 3587
Tsuruga Categories
Test Equipment
Measuring Instruments
Printer
Industrial Monitor
More Tsuruga Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL