Sign In
Upload
Manuals
Brands
Tsuruga Manuals
Test Equipment
8526
Tsuruga 8526 Manuals
Manuals and User Guides for Tsuruga 8526. We have
1
Tsuruga 8526 manual available for free PDF download: Instruction Manual
Tsuruga 8526 Instruction Manual (94 pages)
AC/DC Withstanding Voltage Tester
Brand:
Tsuruga
| Category:
Test Equipment
| Size: 3 MB
Table of Contents
Table of Contents
4
1 Preface
6
Initial Setting at the Time of Delivery
6
2 Confirmation Prior to Use
7
Unpacking
7
Cautions for Handling
7
3 Name of Parts and Functions
8
Front Panel
8
Rear Panel
11
4 Preparation Prior to Use
13
Zero Adjustment of Output Voltmeter
13
Connection of Protective Ground Terminal
13
Connection with External Control Device
13
Connection of High Voltage Cable
13
Connection of Power Supply Cable
14
Throw in and Shut off of Power Source
14
Before the Test
14
5 Setting Items in each Mode
15
READY Status
15
Setting Mode of Test Condition
15
Memory Write-In Mode
15
Memory Read-Out Mode
15
6 Kind of Test Mode and Flow of Setting
16
Kind of Test Mode
16
Flow of Setting
16
7 Setting of Test Mode
17
Status of Display and Expression in Instruction Manual
17
Selection of each Test Mode
17
8 Setting of Test Condition for Withstanding Voltage Test
18
Test Range of Withstanding Voltage Test
18
Referential Voltage
19
High Limit of Leak Current
21
Low Limit of Leak Current
22
Test Time
24
9 Memory Function
26
Configuration of Memory
26
Memory Write-In
26
Memory Read-Out
27
10 Test Procedure (from Start to Judgement Result)
28
Setting of Test Voltage (before Starting Test)
28
Test Operation
28
11 Key Lock
31
12 Special Test Mode
32
13 Remote Control
33
Operation by REMOTE Connector
33
Operation by REMOTE Terminal
33
Operation by REMOTE/OUT Connector
34
Operation by REAR:MEM
35
Priority of each Remote Control
35
14 External Control
36
Control by REMOTE/OUT Connector
36
Arrangement and Function of Connector Pins
36
Interlock Signal
37
Protective Function (PROTECTION)
37
Output Signals and Power Supply for Control
38
15 Status Output
39
Name of STATUS OUTPUT and Condition for Output
39
Specifications of Status Output
39
Setting of Condition for Status Output
40
16 Timing Chart
41
17 Adjustment of Buzzer Sound
42
18 Error Message
43
19 Maintenance
44
Cleaning
44
Failure Symptom
44
Replacement of Fuse
44
20 Specifications
45
Rs-232C Interface for Model 8526 Instruction Manual
52
1 Specifications
53
2 Connection
54
Connectors and Signals
54
Connection with Host (Reference)
54
3 Explanation of Communication Method
55
Communication Method for Command
55
Basic Format of Read-Out Command
57
Basic Format of Setting and Operation
57
4 Explanation of Command
58
Table of Command
58
Explanation of each Command
59
KEYLOCK= (Setting of Keylock)
60
KEYLOCK? (Read-Out of Keylock Status)
60
FORMAT= (Setting of Response Format)
61
FORMAT? (Read-Out of Response Format)
61
RESPONSE= (Setting of Response)
62
RESPONSE? (Read-Out of Setting of Response)
62
MODE= (Setting of Test Mode)
63
MODE? (Read-Out of Test Mode)
63
START (Start of Test)
64
RESET (Stop of Test, Judgement Reset)
64
STATUS? (Read-Out of Status)
65
IDNT? (Read-Out of Tester Identification)
66
AVOLT= (Setting of Test Voltage Range of AC Withstanding Voltage Test)
66
AVOLT? (Read-Out of Test Voltage Range of AC Withstanding Voltage Test)
66
ALEVEL= (Setting of Referential Voltage of AC Withstanding Voltage Test)
67
ALEVEL? (Read-Out of Referential Voltage of AC Withstanding Voltage Test)
67
ALOW= (Setting of Low Limit of Leak Current of AC Withstanding Voltage Test)
69
ALOW? (Read-Out of Low Limit Value of Leak Current of AC Withstanding Voltage Test)
69
ATIMER= (Setting of Test Time of AC Withstanding Voltage Test)
70
ATIMER? (Read-Out of Test Time of AC Withstanding Voltage Test)
70
DVOLT= (Setting of Test Voltage Range of DC Withstanding Voltage Test)
71
DVOLT? (Read-Out of Test Voltage Range of DC Withstanding Voltage Test)
71
DLEVEL= (Setting of Referential Voltage of DC Withstanding Voltage Test)
72
DLEVEL? (Read-Out of Referential Voltage of DC Withstanding Voltage Test)
72
DHIGH? (Read-Out of High Limit Value of Leak Current of DC Withstanding Voltage Test)
73
DLOW= (Setting of Low Limit of Leak Current of DC Withstanding Voltage Test)
74
DLOW? (Read-Out of Low Limit Value of Leak Current of DC Withstanding Voltage Test)
74
DTIMER= (Setting of Test Time of DC Withstanding Voltage Test)
75
DTIMER? (Read-Out of Test Time of DC Withstanding Voltage Test)
75
JUDGE? (Read-Out of Judgement Result)
76
SET: (Setting of Parameters of Test Condition)
78
SET:? (Lump Read-Out of Parameters of Test Condition)
78
MEMORY= (Setting of Memory Number)
79
MEMORY? (Read-Out of Memory Number)
79
MEM no : (Setting of Test Condition to Memory)
80
MEM no :? (Read-Out Memorized Test Condition)
80
BUZZ= (Setting of Buzzer Sound)
81
BUZZ? (Read-Out of Set Value of Buzzer Sound)
81
5 Error
82
6 Cautions
82
7 Sample Program
83
Advertisement
Advertisement
Related Products
Tsuruga 8507
Tsuruga 8505
Tsuruga 8527
Tsuruga 8528
Tsuruga 8525
Tsuruga 3587
Tsuruga Categories
Test Equipment
Measuring Instruments
Industrial Monitor
Printer
More Tsuruga Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL