Sign In
Upload
Manuals
Brands
Tsuruga Manuals
Test Equipment
8525
Tsuruga 8525 Manuals
Manuals and User Guides for Tsuruga 8525. We have
1
Tsuruga 8525 manual available for free PDF download: Instruction Manual
Tsuruga 8525 Instruction Manual (119 pages)
Withstanding Voltage & Insulation Resistance Tester
Brand:
Tsuruga
| Category:
Test Equipment
| Size: 4 MB
Table of Contents
Table of Contents
4
Preface
6
Initial Setting at the Time of Delivery
6
Confirmation Prior to Use
7
Unpacking
7
Cautions for Handling
7
Name of Parts and Functions
8
Front Panel
8
Rear Panel
11
Preparation Prior to Use
13
Zero Adjustment of Output Voltmeter
13
Connection of Protective Ground Terminal
13
Connection with External Control Device
13
Connection of High Voltage Cable
13
Before the Test
14
Throw in and Shut off of Power Source
14
Connection of Power Supply Cable
14
Setting Items in each Mode
15
READY Status
15
Setting Mode of Test Conditions
15
Memory Write-In Mode
15
Memory Read-Out Mode
15
Flow of Setting
16
Kind of Test
16
Kind of Test and Flow of Setting
16
Setting of Test Item
17
Status of Display and Expression in Instruction Manual
17
Setting of each Test Item
17
Key Lock
18
Setting of Test Condition for Withstanding Voltage Test
19
Test Range of Withstanding Voltage Test
19
Referential Voltage
20
High Limit of Leak Current
22
Low Limit of Leak Current
23
Test Time
25
Setting of Test Condition for Insulation Resistance Test
28
Test Range of Insulation Resistance Test
28
High Limit of Resistance Value
29
Low Limit of Resistance Value
31
Time of Mask Timer
32
Test Time
33
Discharging Function
35
Memory Function
36
Configuration of Memory
36
Memory Write-In
37
Memory Read-Out
38
Test Procedure (from Start to Judgement Result)
39
Setting of Test Voltage for Withstanding Voltage Test (before Starting Test)
39
W-I Test (Withstanding Voltage Test → Insulation Resistance Test)
41
I-W Test (Insulation Resistance Test → Withstanding Voltage Test)
45
W Test (Withstanding Voltage Single Test)
49
I Test (Insulation Resistance Single Test)
52
Special Test Mode
55
Remote Control
56
Operation by REMOTE Connector
56
Operation by REMOTE Terminal Block
56
Operation by REMOTE/OUT Connector
57
Operation by REAR:MODE
58
Priority of each Remote Control
59
External Control
60
Control by REMOTE/OUT Connector
60
Arrangement and Function of Connector Pins
60
Interlock Signal
61
Protective Function (PROTECTION)
61
Output Signals and Power Supply for Control
62
Status Output
63
Name of STATUS OUTPUT and Condition for Output
63
Specifications of Status Output
63
Setting of Condition for Status Output
64
Timing Chart
65
Adjustment of Buzzer Sound
66
Monitor Output of Voltage
67
Error Messages
68
Maintenance
69
Cleaning
69
Failure Symptom
69
Replacement of Fuse
69
Specifications
70
Rs-232C Interface for Model 8525 Instruction Manual
77
Specifications
78
Connection with Host (Reference)
79
Connections
79
Connectors and Signals
79
Communication Method for Command
80
Explanation of Communication Method
80
Basic Format of Read-Out Command
82
Basic Format of Setting and Operation
82
Explanation of Command
83
Table of Command
83
Explanation of each Command
84
REMOTE= (Setting of Remote Control)
84
REMOTE? (Read-Out of Setting of Remote Control)
84
KEYLOCK= (Setting of Keylock)
85
KEYLOCK? (Read-Out of Keylock Status)
85
FORMAT= (Setting of Response Format)
86
FORMAT? (Read-Out of Response Format)
86
RESPONSE= (Setting of Response)
87
RESPONSE? (Read-Out of Setting of Response)
87
MODE? (Read-Out of Test Mode)
88
RESET (Stop of Test, Judgement Reset)
89
START (Start of Test)
89
STATUS? (Read-Out of Status)
90
IDNT? (Read-Out of Tester Identification)
91
WVOLT= (Setting of Test Voltage Range of Withstanding Voltage Test)
91
WLEVEL= (Setting of Referential Voltage of Withstanding Voltage Test)
92
WLEVEL? (Read-Out of Referential Voltage of Withstanding Voltage Test)
92
WHIGH= (Setting of High Limit of Leak Current)
93
WHIGH? (Read-Out of High Limit Value of Leak Current)
93
WLOW? (Read-Out of Low Limit Value of Leak Current)
94
WTIMER? (Read-Out of Test Time of Withstanding Voltage Test)
95
IVOLT= (Setting of Test Voltage Range of Insulation Resistance Test)
96
IVOLT? (Read-Out of Test Voltage Range of Insulation Resistance Test)
96
IHIGH= (Setting of High Limit of Resistance Value)
97
IHIGH? (Read-Out of High Limit of Resistance Value)
97
ILOW= (Setting of Low Limit of Resistance Value)
98
ILOW? (Read-Out of Low Limit of Resistance Value)
98
IMASK= (Setting of Mask Time of Insulation Resistance Test)
99
IMASK? (Read-Out of Mask Time of Insulation Resistance Test)
99
ITIMER= (Setting of Test Time of Insulation Resistance Test)
100
ITIMER? (Read-Out of Test Time of Insulation Resistance Test)
100
DISCHARGE= (Setting of Discharge Function of Insulation Resistance Test)
101
DISCHARGE? (Read-Out of Discharge Function of Insulation Resistance Test)
101
DATA? (Lump Read-Out of Test Result)
103
SET: (Setting of Parameters of Test Condition)
105
MEM no : (Setting of Test Condition to Memory)
107
BUZZ= (Setting of Buzzer Sound)
108
BUZZ? (Read-Out of Set Value of Buzzer Sound)
108
Cautions
109
Error Codes and Hints to Solve
109
Sample Program
110
Advertisement
Advertisement
Related Products
Tsuruga 8507
Tsuruga 8505
Tsuruga 8526
Tsuruga 8527
Tsuruga 8528
Tsuruga 3587
Tsuruga Categories
Test Equipment
Measuring Instruments
Printer
Industrial Monitor
More Tsuruga Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL