Sign In
Upload
Manuals
Brands
Studer Manuals
Remote Control
RCC-03
Studer RCC-03 Manuals
Manuals and User Guides for Studer RCC-03. We have
5
Studer RCC-03 manuals available for free PDF download: User Manual, Quick Manual, Reference Manual
Studer RCC-03 User Manual (104 pages)
Remote control and programming unit
Brand:
Studer
| Category:
Extender
| Size: 3 MB
Table of Contents
Table of Contents
5
1 Foreword
9
Conventions
9
Product Recycling
9
EC Declaration of Conformity
10
Studer Innotec Contact Details
10
Your Reseller Contact Details
10
2 Warnings and Caution
11
Warranty
11
Limitation of Responsability
11
Safety Instructions
11
Acceptance of the Software Licence and Updates
11
Compatibility
12
Access Code for Extended Functions
12
3 Introduction
13
Models Concerned
13
Controls and Indicators
13
SD Card
14
4 Connection
15
Series Connection
15
Xtender XTH
16
Xtender XTM
16
Rcc-02
16
Xtender XTS
17
Variostring
17
Variotrack
17
Bsp
17
Xcom-232I
18
5 Dimensions
19
6 Quick Start Guide
20
Setting of the Language
20
Adaptation to the Source
20
Adaptation to the Battery
21
Activation of the Function Smart-Boost
22
7 Basic Displays
23
8 Activating and Deactivating the Combi Xtender
24
9 Quick Setting of the Maximum Source AC Current
24
10 Setting of the RCC Remote Control
25
Setting of the Language {5000
25
Other Languages {5036
25
Setting of Time {5001} and Date {5002
26
User Level {5012
26
Drive the Remote Control to the User Level Basic {5019
26
INSTALLER - Modification of the Xtender Parameters Thresholds Together {5042
26
Force All Xtender Parameters to Threshold {5043
26
Restore the Default Thresholds of the Xtender Parameters {5044
26
Data Logger {5057
27
Data Logger Enabled {5101
27
Backup of the Current Day Data {5059
27
Backup and Restoring {5013
27
Backup of All Files {5041} (System Backup)
27
Restore All Files {5068} (System Recovery)
27
Apply Configuration Files (Master File) {5070
28
Separator of the Csv Files {5032
28
Advanced Backup Functions {5069
28
Adjusting the Contrast
29
Back-Lighting {5007
29
Backlight Modes {5093
29
Duration of the Back-Lighting {5009
29
Red Back-Lighting if the Xtender Is off and if There Is a Fault {5026
29
Extended and Special Functions {5021
29
Choice of the Display by Default {5073
29
Inactivity Period before Returning to the Standard Display {5010
29
Duration of Display for Quick Messages {5011
30
Acoustic Alarm {5027
30
Remote Control Acoustic Alarm Duration {5031
30
Switching on and off of System on Level View Only {5056
30
11 Information on the Operating Mode of the Installation
31
Display of the Parallel and Three-Phase Systems
33
12 Messages and Account of Events
34
000) Warning: Battery Voltage Low
34
003) AC-In Synchronization in Progress
34
004) Input Frequency AC-In Wrong
35
006) Input Voltage AC-In too High
35
007) Input Voltage AC-In too Low
35
008) Halted: Inverter Overload SC
35
014) Halted: over Temperature el
35
Halted: Inverter Overload BL
36
016) Warning: Fan Error Detected
36
018) Warning: Excessive Battery Voltage Ripple
36
019) Halted: Battery under Voltage
36
020) Halted: Battery Overvoltage
36
021) Input Limit Reached, no Transfer
36
022) Error: Voltage Presence on AC-Out
37
023) Error: Inverter Phase Not Defined
37
Check the Clock Battery
37
041) Warning: Overtemperature TR
37
042) Halted: Unauthorized Energy Source at the Output
37
058) Error: Synchronization with Master Lost
37
059) Halted: Inverter Overload HW
37
Warning: Time Security for Auxiliary Contacts
38
062) Warning: Genset, no AC-In Coming after AUX Command
38
Stored Events
38
13 Data Logging
39
Functioning
39
Analysis and Visualization of the Data with the XTENDER Data Analysis Tool
39
14 Setting of the Xtender
40
General
40
Configuration on a System with Several Xtenders
40
Utilisation and Access Levels
40
Pre-Defined Functions of the Auxiliary Relays
40
Access to the Parameters
41
Access to a Parameter by Its Number
41
Access to a Parameter Via the Menu
41
INSTALLER - Utilisation and Access Levels
42
Basic Settings {1100
42
Setting of the Basic Parameters by Means of the Potentiometer in the XTS {1551
42
Maximum Current of the AC Source (Input Limit) {1107
43
Charge Current {1138
43
Smart Boost Authorized {1126
44
Authorized Inverter {1124
44
Type of Detection of the Grid Loss (AC-In) {1552
44
Standby Level {1187
45
Restore Default Configurations {1395
45
INSTALLER - Restore Factory Settings {1287
45
Management and Battery Cycle {1137
46
Authorized Charger {1125
49
Battery Charge Current {1138
49
Temperature Correction Coefficient {1139
49
Undervoltage {1568
49
Maximum Operating Voltage {1121
51
Reactivation Voltage after Battery Overvoltage {1122
51
Battery Maintenance Voltage (Floating) {1140
51
Force Passage to Floating Mode {1467
51
New Cycle {1141
51
Absorption Phase {1451
52
Equalization Phase {1452
53
Reduced Floating Phase {1453
55
Periodic Absorption Phase {1454
55
Inverter {1186
56
Authorized Inverter {1124
56
Output Voltage {1286
56
Increase of the Linear AC-Out Voltage with the Battery Voltage {1548
57
Maximum Increase of the AC-Out Voltage by the Battery Voltage {1560
57
Frequency {1112
57
Increase of the Frequency at Full Battery {1536
57
Frequency Increase with the Battery Voltage {1549
58
Maximum Increase of the Frequency {1546
58
Speed of the Change Output Voltage/Frequency According to the Battery Voltage {1534
59
Standby and Start (Load Detection) {1420
59
Solsafe Presence, Energy Source at AC-Out Side {1438
60
AC-In and Transfer {1197
60
Authorized Transfer {1128
60
Delay before Closing of the Transfer Relay {1580
60
Smart-Boost Authorized {1126
60
Limitation of the Smart-Boost Power {1607
60
Maximum Current of the AC Source (Input Limit) {1107
61
Adaptation of the Input Current {1471
61
Authorization to Exceeding the Maximum Current of the Source (Input Limit) Without Interrupting the Transfer {1436
62
Type of Detection of the Grid Loss (AC-In) {1552
62
Sensitiveness of the Detection « Tolerating » of Grid Loss (AC-In) {1510
63
Transfer AC-In for Delayed Transfer Opening {1199
63
Delay before Passing to Inverter {1198
63
Immediate Transfer AC-In Voltage {1200
63
INSTALLER - Absolute Maximum Input Voltage {1432
63
Delta Frequency Allowed above the Standard Input Frequency {1505
63
Delta Frequency Allowed below the Standard Input Frequency {1506
63
Duration of Erroneous Frequency before Disconnecting the Transfer Relay {1507
63
AC-In Current Active Filtering {1575
64
INSTALLER - Use an Energy Quota on AC-Input {1557
64
INSTALLER - AC-In Energy Quotas {1559
64
Configuration of Auxiliary Contacts 1 and 2 {1201} {1310
64
Switching Mode {1202} {1311
65
Combination of Events Mode {1497} {1498
65
Temporal Restrictions {1203} {1312
65
Contacts Activated with Set Schedules {1269} {1378
66
Contacts Activated by an Event {1455} {1456
66
Contacts Activated by the Battery Voltage {1245} {1353
68
Contacts Activated by Inverter Power or Smart-Boost {1257} {1366
69
INSTALLER - Contacts Activated According to the Battery Temperature {1503} {1504
69
Contacts Activated on Battery State of Charge (SOC) {1501} {1502} (Function Active Only with a BSP)
70
Security: Limit the Time of Activation {1512} {1513
70
Maximum Duration of Activation {1514} {1515
70
Reset All Settings {1569} {1570
70
Auxiliary Contacts 1 and 2 Extended Functions {1489
71
Generator Startup
71
Generator Control {1491
71
Number of Starting Attempts {1493
71
Starter Pulse (with AUX2) {1492
71
Time before a Starter Pulse {1494
71
Main Contact Hold/Interrupt Time {1574
71
System {1101
72
Command Entry {1537
72
Battery as Priority Energy Source {1296
73
Votage of the Battery Priority {1297
73
Duration of the Acoustic Alarm {1565
73
Automatic Restart {1129
74
Ground/Neutral System {1484
75
INSTALLER - Watchdog Control System {1628} and {1629
75
INSTALLER - Flash Saving of the Parameter {1550
75
Reset of All Inverters {1468
75
Multi Xtender {1282
75
3-Phase Integral Mode {1283
76
Multiple Authorized Inverters {1461
76
Multiple Independent Inverters {1462
76
Battery Cycle Synchronized by the Master {1555
76
Authorize the Stand-By of the Secondary Inverters (Slaves) {1547
76
Splitphase: L2 with 180 Degrees Phase Displacement {1571
76
INSTALLER - Compatible Minigrid {1437
76
INSTALLER - Minigrid with Battery Energy Sharing {1577
76
Grid-Feeding {1522
77
Grid-Feeding Authorized {1127
77
Maximum Grid-Feeding Current {1523
77
Forced Grid-Feeding {1524} {1525} {1526
78
INSTALLER - Dephased Injection {1610
78
INSTALLER - Cos Phi at P=0% {1622
79
INSTALLER - Cos Phi at a Given Power. Cos Phi {1623}, P= {1613
79
INSTALLER - Cos Phi at P=100% {1624
79
15 Information on the System
80
Remote Controls
80
Xtender
80
16 Software(S) Updating
81
Updating Process
81
17 Application Examples
82
General Use: Inverter, Charger with Grid
82
Use of a Limited Power Source
82
Use to Increase the Power on an Existing Installation
83
Load Shedding of the Second Priority Loads
83
18 Appendices
84
Appendix 1: List of Configuration Interdependencies
84
19 Parameter Tables
85
Remote Control Parameters
85
Inverter Parameters
87
20 Parameter Index {XXXX
99
Advertisement
Studer RCC-03 User Manual (51 pages)
Remote control and programming unit for the Xtender
Brand:
Studer
| Category:
Remote Control
| Size: 1 MB
Table of Contents
User Manual
1
Table of Contents
3
Foreword
7
Conventions
7
Product Recycling
7
Studer Innotec Contact Details
8
Your Reseller' Contact Details
8
Warnings and Caution
8
Warnings and Caution
9
Warranty
9
Limitation of Responsability
9
Safety Instructions
9
Acceptance of the Software Licence and Updates
9
Introduction
11
Models Concerned
11
Controls and Indicators
11
SD Card
11
Connection
12
Series Connection
12
Dimensions
13
Rcc-02
13
Rcc-03
13
Quick Start Guide
14
Adjustment of the Language
14
Adaptation to the Source
14
Adaptation to the Batterie
15
Activation of the Function Smart-Boost
16
Basic Displays
17
Activating and Deactivating the Combi Xtender
18
Adjustment of the RCC Remote Control
19
Adjustment of the Language {5000
19
Adjustment of Date {5002) and Time {5001
19
Adjustment of the Contrast {5006
19
Adjustment of the Back-Lighting {5007
19
Back-Lighting Always off {5008
19
Duration of the Back-Lighting {5009
20
Red Back-Lighting if the Xtender Is off and if There Is a Fault {5026
20
Inactivity Period before Returning to the Standard Display {5010
20
Duration of Display for Quick Messages {5011
20
Acoustic Alarm {5027
20
User Level {5012
20
Drive the Remote Control to the User Level Basic {5019
20
Backup and Restoring {5013
20
Backup of Statistics {5014
20
Backup of Remote Control Configurations {5015
21
Backup of Xtender Configurations {5017
21
Loading the Remote Control Configurations {5016
21
Loading the Xtender Configurations {5018
21
Loading a Master File {5034
21
Separator of the Csv Files {5032
21
Information on the Operating Mode of the Installation
22
Display of the Parallel and Three-Phase Systems
23
Event History
24
Alarm Low Battery Voltage
24
Stop Battery Voltage too Low
24
Stop High Battery Voltage
24
Message AC in Synchronisation in Progress
24
Error Incorrect Input Frequency
25
Error Input Voltage too High
25
Error Input Voltage too Low
25
Stop Inverter Overvoltage
25
Stop Overtemperature
25
Stop Excessive Battery Voltage Ripple
25
Message Power Sharing Exceeded; Transfer Prohibited
26
Error Voltage at AC out
26
Error Phase Not Defined
26
Stored Events
26
Adjustment of the Combi Xtender
27
General
27
Configuration on a System with Several Xtenders
27
Utilisation and Access Levels
27
Pre-Defined Functions of the Auxiliary Relays
27
Menu
27
Basic Configurations {1100
28
Authorised Inverter {1124
28
Locking {1123
28
Maximum Current of the AC Source (Power Sharing) {1107
28
Authorised Charger {1125
29
Authorised Transfer {1128
29
Automatic Restart {1129
29
Leadtime to Counting the Battery Under-Voltages Allowed before Final Stop {1404
29
Number of Battery Under-Voltages Allowed before Final Stop {1304} and
29
Smart Boost Authorised {1126
29
Leadtime to Counting the Critical Battery Under-Voltages Allowed before Final Stop {1405
30
Number of Critical Battery Under-Voltages before Final Stop {1305} and
30
Restore Default Configurations {1395
30
Battery Cycle and Charger {1137
30
Battery Maintenance Voltage (Floating) {1140
33
Charge Current {1138
33
Force New Cycle {1142
33
Force Passage to Floating Mode {1467
33
New Cycle {1141
33
New Priority Cycle on the Absorption and Equalization Phases {1149
33
Temperature Correction Coefficient {1139
33
Voltage 1 for a New Cycle {1143} and Duration at Undervoltage 1 for a New Cycle {1144
33
Voltage 2 for a New Cycle {1145} and Duration at Undervoltage 2 for a New Cycle {1146
33
Absorption Phase {1451
34
Absorption Voltage {1156
34
Authorised Absorption {1155
34
Authorised Equalization {1163
34
Completion of Absorption Released by the Current {1158
34
Current at End of Absorption {1159
34
Duration of Absorption {1157
34
Equalization Phase {1452
34
Start Equalization {1162
34
Duration of Equalization {1165
35
Equalization at Set Intervals {1284]
35
Equalization before Absorption Phase {1291
35
Equalization Current {1290
35
Equalization Voltage {1164
35
Number of Cycles Prior to Equalization {1166
35
Weeks between Equalizations {1285
35
End of Equalization Activated by the Current {1168
36
End of Equalization Current {1169
36
Inverter Configurations {1186
36
Output Voltage {1286
36
Standby Level {1187
36
Acoustic Alarm of the Battery Under-Voltage {1196
37
Duration of the Acoustic Alarm {1469
37
Level of Battery Under-Voltage at no Load {1108
37
Combi Configurations Inverter-Charger {1197
37
Minimum AC in Voltage to Authorise the Charging {1309
37
Transfer AC-In for Delayed Transfer Opening {1199
37
Activate Immediate Detection of Grid Outage (UPS) {1435
38
Authorisation for Exceeding the Power Sharing Current Without Interrupting the Transfer {1436
38
Delay before Closing of the Transfer Relay {1528
38
Delay before Passing to Inverter {1198
38
Immediate Transfer AC-In Voltage {1200
38
Solsafe Presence {1438
38
Configurations for Auxiliary Contacts 1 and 2 {1201} {1310
38
Simple Functions
39
Combination of Events Mode {1497} {1498
39
Switching Mode {1202} {1311
39
Battery Overvoltage {1227) {1335
40
Battery Undervoltage Alarm {1226} {1334
40
Contacts Activated by an Event {1455} {1456
40
Limit the Time of Activation {1512} {1513
40
Maximum Duration of Activation {1514} {1515
40
Temporal Restrictions {1203} {1312
40
Xtender off {1225} {1333
40
AC in Present with Fault {1234} {1342
41
AC in Present {1235} {1343
41
AC out Present {1237} {1345
41
Active Charger {1231} {1339
41
Active Inverter {1232} {1340
41
Inverter or Smart Boost Overload {1228} {1336
41
No Overtemperature Alarm {1520} {1521
41
Overtemperature {1229} {1337
41
Smart Boost Active {1233} {1341
41
Transfer Relay Drawn {1236} {1344
41
Contacts Activated by Inverter Power or Smart Boost {1257} {1366
42
Contacts Activated with Set Schedules {1269} {1378
42
Deactivate if the Battery Is in Floating Mode {1516} {1517
42
Dynamic Compensation of the Thresholds {1288} {1354
42
Extended Functions {1489
43
Duration between the Starter Attempts {1494
43
Duration of Starter Impulse {1492
43
Generator Startup {1490
43
Generator Startup {1491
43
Number of Startup Attempts {1493
43
Multi Xtender {1282
43
3-Phase Integral Mode {1283
43
Information on the System
44
Remote Controls
44
Xtender
44
Updates
45
Updating Process
45
Compatibility
45
Application Examples
46
Général Use : Inverter, Charger with Grid
46
Use of a Limited Power Source
46
Use to Increase the Power on an Existing Installation
47
Load Shedding of the Second Priority Loads
47
Annexes
48
Annexe 1 : List of Configuration Interdependencies
48
Notes
50
Studer RCC-03 Quick Manual (44 pages)
remote control
Brand:
Studer
| Category:
Control Unit
| Size: 1 MB
Table of Contents
Table of Contents
2
1 Introduction
3
Contents: RCC Remote Control
3
2 Limitation of Responsibility
3
Quick Guide RCC-02
3
3 Connection
4
Correct Positioning of the RCC
4
Setting the Link Ends
4
4 Using the Remote Control
4
5 System Configuration
5
6 Adjustment of the Parameters
6
Configuration of the RCC (Remote Control)
6
Configuration of the Xtender (Inverter/Charger)
8
Configuration of the BSP (Battery Status Processor)
16
Configuration of the Xcom-CAN (Multi-Protocol Communication Module)
17
Configuration of the Variotrack (MPPT Solar Charge Controller)
18
Configuration of the Variostring (MPPT Solar Charge Controller)
22
7 User Information
26
User Information on Xtender Displays
26
User Information on BSP Displays
28
User Information on Xcom-CAN Displays
28
User Information on Variotrack Displays
29
User Information on Variostring Displays
30
8 Messages, Account of Events & Troubleshoot
31
9 Dimensions
43
Rcc-02
43
Rcc-03
43
Advertisement
Studer RCC-03 Reference Manual (2 pages)
Remote control and programming unit
Brand:
Studer
| Category:
Remote Control
| Size: 2 MB
Table of Contents
Battery
1
Voltage
1
Real Charge Current
1
Programmed Charge Current
1
Charging Phase (Bulk Charge, Absorption, Floating Charge…)
1
Working Mode (Inverter, Charger...)
1
Input Voltage
1
Input Current
1
Input Frequency
1
Output Voltage
1
Adjustment of the Xtender
2
Basic Settings
2
Maximum Current of the AC Source (Power Sharing)
2
Charge Current
2
Battery Management and Cycle
2
Absorption Phase
2
Equalization Phase
2
Inverter
2
Authorized Transfer
2
Battery Overvoltage
2
Studer RCC-03 Quick Manual (9 pages)
Brand:
Studer
| Category:
Remote Control
| Size: 0 MB
Table of Contents
General Information
3
Mounting and Installation
4
Technical Data
8
Maintenance and Recycling
8
Advertisement
Related Products
Studer RCC-02
Studer RCC-01
Studer RPS-01
Studer Xtender RCM-01
Studer Retrofit Kit MkII
Studer RCM-10
Studer RHU 500
Studer RHU 100
Studer Categories
Inverter
Music Mixer
Battery Charger
Recording Equipment
Tape Deck
More Studer Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL