Studer RCC-02 Reference Manual

Studer RCC-02 Reference Manual

Remote control and programming unit
Hide thumbs Also See for RCC-02:

Advertisement

Quick Links

User information

Battery

Voltage

Real charge current

Programmed charge current

Voltage ripple
Charging phase
(bulk charge, absorption, floating charge...)
Dynamic compensation of the voltage
(compensation of threholds due to the battery internal
resistance)

Working mode (inverter, charger...)

Temperature (provided if a sensor is installed)
Compensation implied by the temperature
(provided if a sensor is installed)
Discharge of the previous day
Discharge of the current day
Input AC

Input voltage

Input current

Input power AC-In

Input frequency

Energy from AC-In of the previous day
Energy from AC-In of the current day
Output AC

Output voltage

Output current

Reference guide
Output power

Output frequency

Consumers energy of the previous day
Consumers energy of the of the current day
Remote control and
General
programming unit
State of the transfer contacts
State of the inverter-charger contacts
State of the auxiliary contacts
Working mode of the auxiliary contacts
RCC-02 and RCC-03
Lock states
Smart Boost active
for the Xtender
Active sharing of the available power
(Power Sharing)
Messages and account of events
Alarm: Low battery voltage
V. 3.2.5
Message: AC IN synchronization in progress
51M
Message: Wrong AC-In input frequency
Message: Too high AC-In input voltage
Quick start guide
Message: Too low AC-In input voltage
Stop: Overload inverter SC
Setting of the language
Stop : Overtemperature EL
Stop: Overload inverter BL
To begin, set your remote control RCC for a display
Alarm: Ventilation fault detected
of the information in English.
Alarm: Excessive battery ondulation
The basic display is:
Stop: Too low battery voltage
Stop: high battery voltage
Message: Power sharing exceeded;
transfer prohibited
Error: Voltage at AC Out
Error: Phase not defined
Press 1 time on the key
"arrow
downwards"
Message: Control the battery of the clock
display the following screen:
Alarm: Overtemperature TR
Once beyond this screen
Stop: Source at the output
you can come back to it by
Error: Lost of synchro master
means of the key "arrow upwards" .
Stop: Overload inverter HW
Alarm: Maximum duration security for
Press the key SET to enter
auxiliary contact
the remote control settings.
Alarm: Genset problem, no AC-In after a start by
The screen of the language
means of the auxiliary contact
choice appears.
Adjustment of the remote control
Press once more the key SET
to
modify
the
language.
The language then appears
in reverse video.
With the keys "arrow upwards" and "arrow
downwards" choose the language you wish. Then
validate your choice by means of the key SET (OK).
We can now leave the setting of the remote
control with the key ESC.
Language
{5000}
Other languages
{5036}
Adaptation to the source
Time
{5001}
Date
{5002}
It is a matter of indicating to the Xtender the
User level
{5012}
power available to charge the batteries and to
Drive the remote control to the user level basic
{5019}
supply the users. In order to adapt your
Backup and restoring
{5013}
installation to the source it is connected to,
Backup of all files
{5041}
proceed as follows:
Messages backup
{5030}
Backup of remote control configurations
{5015}
The basic display is:
Backup of Xtender configurations
{5017}
Load Xtender parameters preset
{5045}
Loading the remote control configurations
{5016}
Loading the Xtender configurations
{5018}
Loading a master file
{5034}
Separator of the csv files
Press 2 times on the key
{5032}
"arrow
downwards"
Contrast
{5006}
display the following screen:
Back-lighting
{5007}
Once beyond this screen
Back-lighting always off
{5008}
you can come back to it by
Duration of the back-lighting
{5009}
means of the key "arrow upwards" .
Red back-lighting if Xtender OFF and default
{5026}
Inactivity period before returning to standard
display
{5010}
Duration of display for quick messages
{5011}
Accoustic alarm
{5027}
Press the key SET to access
to the settings.
Then again on the key SET
to access to the basic
parameters.
to
Press the key SET to modify the value of this
parameter (it appears in reverse video).
By means of the keys "arrow upwards" and "arrow
downwards" change the value to adapt it to your
source and validate your setting with the key SET
(OK).
Adaptation to the battery
In order that your Xtender manages the best
current
possible the energy stored in your batteries and
that it charges them optimally, it is necessary to
indicate the current which they can be charged
with. You will find this value in the technical data
provided by your batteries manufacturer.
The basic display is:
Press 2 times on the key
"arrow
downwards"
to
display the following screen:
Once beyond this screen
you can come back to it by
means of the key "arrow upwards" .
Press the key SET to access
to the settings.
Then again on the key SET
to access to the basic
parameters. With the key
"arrow downwards" ,
to
access the setting "Battery
and charger cycle" .
You are now going to set
the charge current for the
batteries:
Press the key SET to modify the value of this
parameter (it appears in reverse video). With the
keys "arrow upwards" and "arrow
downwards" change the value to adapt your
battery and validate your setting with the key SET
(OK).
Activation of the function Smart-Boost
If your AC-In source is limited in power, the Xtender
can work as a support and add the missing
power for your loads.
First of all, check that you have adapted the
Xtender to your source (see previous chapter:
Adaptation to the source {1107})
The basic display is:
Press 2 times on the key
"arrow
downwards"
to
display the following screen:
Once beyond this screen you
can come back to it by
means of the key "arrow upwards" .
APress the key SET to access
to the settings.
Then again on the key SET
to access to the basic
parameters. Press 2 times on
the key "arrow downwards" .
You
reach
now
the
parameter for authorization of the Smart-Boost
function {1126}.
You can now authorize the
function. Press the key SET to
access this parameter in
modification mode, then the
keys UP or DOWN to change
the option. To end up, validate with the key SET.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RCC-02 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Studer RCC-02

  • Page 1 {1126}. Loading the remote control configurations {5016} Working mode of the auxiliary contacts Then again on the key SET RCC-02 and RCC-03 Loading the Xtender configurations {5018} Lock states to access to the basic You can now authorize the...
  • Page 2 {1142} Voltage 3 Program 3 {1253} {1362} After battery overvoltage {1131} {1212} {1321} Standby and turn on Studer Innotec Voltage 1 for a new cycle {1420} {1143} Duration 3 {1254} {1363} After inverter or Smart-Boost overload Days of the week...

This manual is also suitable for:

Rcc-03

Table of Contents