Sign In
Upload
Manuals
Brands
SIGRIST Manuals
Measuring Instruments
AquaMaster
SIGRIST AquaMaster Water Measuring Manuals
Manuals and User Guides for SIGRIST AquaMaster Water Measuring. We have
2
SIGRIST AquaMaster Water Measuring manuals available for free PDF download: Instruction Manual
SIGRIST AquaMaster Instruction Manual (122 pages)
Multi-Parameter Measuring System with AquaScat 2 WTM / WTM A / HT
Brand:
SIGRIST
| Category:
Measuring Instruments
| Size: 5 MB
Table of Contents
Table of Contents
3
1 General User Information
7
Terms Used in this Document (Glossary)
7
Purpose of the Instruction Manual
7
Target Group of the Documentation
7
Additional Documentation
7
Copyright Provisions
7
Document Storage Location
7
Order Document
8
Proper Use
8
User Requirements
8
Declaration of Conformity
8
Use Restrictions
8
Dangers When Not Used Properly
9
Meaning of the Safety Symbols
9
Meaning of the Pictograms
10
2 Instrument Overview
11
Overview of Aquamaster with Aquascat 2
11
Designation of the Photometer
12
Identification of the Connection Box
13
Scope of Supply and Accessory Parts
14
Aquamaster Technical Data
17
3 General Safety Points
22
Dangers When Using Properly
22
Preventing Undesirable Online Access Attempts
23
Residual Risk
24
Warning and Danger Symbols on the Instrument
24
4 Mounting and Installation
25
Safety Pointers for Electrical Connection
25
Location Selection
25
Mount Base Plate
26
Connecting the Connection Box
27
Position of the Connection Box
29
Fasten Photometer to Base Plate
30
Connecting the Electrical Connections
32
Mount Sensors before Commissioning
35
Connect Water
38
Mounting the Optional Flow Meter
39
5 Commissioning
40
6 Operation
43
Operation Basics
43
Control Elements in Measuring Operation
44
Menu Button
44
Valu Button
44
Info Button
45
Info Button
46
Info Button
47
Diag Button
48
Functions of the Log Screen (Log Button)
49
Displays in Measuring Operation
50
Activating and Deactivating the Screen Lock
51
Switching to Service Operation
52
Control Components in Service Mode
53
Input Elements in Service Operation
53
Numerical Entry
54
Single Selection of Functions
55
Multiple Selection of Functions
55
7 Settings
56
Setting the Operating Language
56
Set Current Outputs
57
Set Limits
58
Upper and Lower Threshold Value of a Limit
59
Reading if Limit Exceeded or Undershot
59
Set Outputs
60
Setting the Measuring Channels and the Display
61
Setting the Date and Time
63
Setting or Changing the Access Code
64
Back up Configured Data
65
8 Servicing
66
Servicing Schedule for Aquamaster
66
Introduction to Handling of the Sensors
67
Removing Sensors
69
Installing Sensors
70
Clean and Calibrate Ph Sensor
71
Clean and Calibrate Conductivity Sensor
74
Clean and Calibrate Redox/Orp Sensor
77
Cleaning and Calibrating the Oxygen Sensor
80
Replace Sensors Configured by SIGRIST
81
Installing an Unconfigured Sensor
82
Clean the Measuring Cell Block
84
Cleaning the Tubing
85
Servicing Schedule for Aquascat 2 WTM/WTM A/HT
86
Fastening the Optics Unit to the Docking Station
87
Checking the Flow Rate and Cleanliness
89
Flow Rate Reduction
91
Manual Adjustment
92
Automatic Adjustment with Aquascat 2 WTM a
94
Cleaning the Parts Which Come into Contact with Water
95
Checking Soiling of the Lenses and Cleaning the Optics
98
Replacing the Air Filter
103
Replacing the Battery
104
9 Troubleshooting
106
Pinpointing Malfunctions
106
Replacing the Fine-Wire Fuses
107
Warning Messages and Effect on Operation
108
Fault Messages and Effect on Operation
109
Prioritized Fault Messages and Their Effect on Operation
111
10 Customer Service Information
112
11 Decommissioning/Storage
113
Decommissioning
113
Storage
114
12 Packaging/Transport/Returning
115
13 Disposal
116
14 Spare Parts List
117
Spare Parts for the Aquamaster
117
Spare Parts for the Aquascat 2 WTM (A) / HT
117
15 Appendix
118
16 Index
120
Advertisement
SIGRIST AquaMaster Instruction Manual (104 pages)
Multi-Parameter Measuring System with SICON M control unit
Brand:
SIGRIST
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Table of Contents
3
1 General User Information
7
Terms Used in this Document (Glossary)
7
Purpose of the Instruction Manual
7
Target Group of the Documentation
7
Additional Documentation
7
Copyright Provisions
7
Document Storage Location
7
Order Document
8
Proper Use
8
User Requirements
8
Declaration of Conformity
8
Use Restrictions
8
Dangers When Not Used Properly
9
Meaning of the Safety Symbols
9
Meaning of the Pictograms
10
2 Instrument Overview
11
Overview of Aquamaster with SICON M
11
Designation of the Connection Box
12
Designation of the SICON M
13
Scope of Supply and Accessories
14
Aquamaster Technical Data
17
Technical Data of the SICON M
18
Technical Data of the Sensors
19
3 General Safety Points
21
Dangers During Normal Use
21
Preventing Undesirable Online Access Attempts
22
Residual Risk
23
Warning and Danger Symbols on the Instrument
23
4 Mounting
24
Location Selection
24
Mounting the Base Plate
24
Position of the Connection Box
25
5 Electrical Installation
26
Safety Pointers for Electrical Connection
26
Installation of the Connection Box
27
Installation of the SICON (M)
28
Removing the Cover from the SICON (M)
28
Overview of the Opened SICON Control Unit
29
Wiring the SICON (M)
30
Installation of the Interfaces Prints (Field Bus Interfaces)
31
Overview of Modbus RTU and Profibus DP
31
Terminal Assignment of Modbus Rtu/Profibus DP
31
Implementation of HART
32
Connecting to HART
32
4-Way Current Output
34
4-Way Current Input
35
Fitting Sensors to the Measuring Cell Block
36
Connecting the Water
38
Mounting the Optional Flow Meter
39
Configuring a Flow Meter with Limit Contact
39
6 Commissioning
40
7 Operation
42
Operation Basics
42
Control Elements in Measuring Operation
43
Menu Button
43
Valu Button
43
Info Button
44
Info Button
45
Info Button
46
Diag Button
47
Functions of the Log Screen (Log Button)
48
Displays in Measuring Operation
49
Activating and Deactivating the Screen Lock
50
Switching to Service Operation
51
Control Components in Service Mode
52
Input Elements in Service Operation
52
Numerical Entry
53
Single Selection of Functions
54
Multiple Selection of Functions
54
8 Settings
55
Setting the Operating Language
55
Set Current Outputs
56
Set Limits
57
Upper and Lower Threshold Value of a Limit
58
Reading if Limit Exceeded or Undershot
58
Set Outputs
59
Setting the Measuring Channels and the Display
60
Setting the Date and Time
62
Setting or Changing the Access Code
63
Back up Configured Data
64
9 Servicing
65
Servicing Schedule
65
Introduction to Handling of the Sensors
66
General Information
66
Measurements with Temperature Dependency
66
Cleaning the Sensor Tips
67
Mechanical Handling of the Sensors
67
Removing the Sensors
68
Installing the Sensors
69
Clean and Calibrate Ph Sensor
70
Clean and Calibrate Conductivity Sensor
73
Clean and Calibrate Redox/Orp Sensor
76
Cleaning and Calibrating the Oxygen Sensor
79
Replace Sensors Configured by SIGRIST
81
Installing an Unconfigured Sensor
81
Integrating Sensors Purchased Afterwards
83
Integrating Colorplus 2 in the Aquamaster
85
Clean the Measuring Cell Block
86
Changing the Battery in the SICON
88
10 Troubleshooting
89
Pinpointing Malfunctions
89
Warning Messages and Effect on Operation
90
Fault Messages and Effect on Operation
92
Prioritized Fault Messages and Their Effect on Operation
93
11 Customer Service Information
94
12 Decommissioning/Storage
95
13 Packaging/Transport/Returning
96
14 Disposal
97
15 Spare Parts List
98
16 Appendix
100
17 Index
102
Advertisement
Related Products
SIGRIST AquaScat S
SIGRIST AquaScat 2 WTM A 24 VDC
SIGRIST AquaScat SG
SIGRIST TurbiGuard AD 40
SIGRIST 118992
SIGRIST 118993
SIGRIST 118994
SIGRIST AquaGuard PR 30
SIGRIST AquaScat 2 HT 24 VDC
SIGRIST AquaScat 2 HT Series
SIGRIST Categories
Measuring Instruments
Smoke Alarm
Industrial Equipment
Monitor
Control Unit
More SIGRIST Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL