Sign In
Upload
Manuals
Brands
SICK Manuals
Transmitter
TRANSIC111LP
User Manuals: SICK TRANSIC111LP Gas Transmitter
Manuals and User Guides for SICK TRANSIC111LP Gas Transmitter. We have
1
SICK TRANSIC111LP Gas Transmitter manual available for free PDF download: Operating Instructions Manual
SICK TRANSIC111LP Operating Instructions Manual (108 pages)
Laser Oxygen Transmitter
Brand:
SICK
| Category:
Transmitter
| Size: 3 MB
Table of Contents
Table of Contents
4
1 Important Information
10
Main Operating Information
10
Installation Location
11
Intended Use
11
Purpose of the TRANSIC111LP
11
Responsibility of User
12
2 Product Description
13
Product Identification
13
Functional Principle/Measuring Principle
13
TRANSIC111LP Probe Design
13
TRANSIC111LP Variants
14
Variant for Extractive Measurement
14
Variant for In-Situ-Measurement
14
Variant for Ambient Gas Measurement
15
3 Installation
16
Project Planning
16
Chemical Tolerance
16
Temperature Conditions
16
Pressure
17
Strong Light Sources Near the Oxygen Measuring Probe
17
Installation
18
Safety Information
18
Installation Angle
19
Prerequisites for Assembly
19
Installation Options
20
Process Conditions for Installation Options
20
TRANSIC111LP Installation for In-Situ Measurement (with Flange)
20
TRANSIC111LP Installation - Extractive
22
TRANSIC111LP Installation - Ambient Gas Measurements
25
Connections
26
Cabling of Signal and Voltage Supply Lines
26
Connecting the 24V PELV Power Supply Unit
29
Connecting the TRANSIC111LP Via an 8-Pole Plug Connector
29
Test Gas Connection (Optional)
30
4 Operation
31
Safety Instructions for Operation
31
Device Interfaces
31
Control Via Keypad
31
Maintenance Interface
32
Analog Output
33
Digital Output Relay
33
RS-485 Interface
33
Settings Using the Keypad
34
Safety Information on Using the Password
34
Short Description: Input of Settings Using the Keypad
34
Menu Navigation Without Password
35
Oxygen Statistics (O 2 )
35
Temperature Statistics (T)
35
Calibration Gas, Actual Value (CAL.C)
36
Display of Active and Undeleted Errors (ERR)
36
Signal Intensity (SIL)
36
Entering the Password (PAS)
37
Menu Navigation with Password Authorization
37
Content in Process Gas: Settings (H2O)
37
Process Pressure: Display and Settings (APP)
37
Analog Output Display and Settings (AOU)
38
Content in Process Gas: Settings (CO2)
38
One-Point Calibration (CAL1)
38
Resetting to the Factory Calibration (FAC)
38
Two-Point Calibration (CAL2)
38
Digital Output (ALA)
39
Resetting the Measuring Device (Rese)
39
Scaling the Analog Output (ASCL)
39
Serial Interface Commands
40
List of Serial Interface Commands
40
Output of Measuring Results
42
Display/Set Continuous Output Interval (Command INTV)
42
Send Measuring Results (Command SEND)
42
Start Continuous Output (Command R)
42
Stop Continuous Output (Command S)
42
Display/Set Serial Communication Mode (Command SMODE)
43
Display/Set Serial Communication Mode for RS-485 (Command SMODE2)
43
Display/Define Serial Communication Settings (Command SERI)
44
Display/Set Serial Communication for RS-485 (Command SERI2)
44
Display Measuring Status (Command MEA)
45
Display Status of Serial Maintenance Interface (Command SCI1)
45
Display Status of Serial RS-485 Interface (Command SCI2)
45
Format Measuring Results (Command FORM)
45
Display/Set Date (Command DATE)
47
Display/Set Time (Command TIME)
47
Network Operation
48
Close Serial Interface in Poll Mode (Command CLOSE)
48
Display/Set Device Address (Command ADDR)
48
Open Communication Line (Command OPEN)
48
Set Echo Mode (Command ECHO)
49
Commands for Access at Maintenance Level
50
Commands for Calibration and Adjustment
50
Hold Outputs for Calibration (Command ADJUST)
50
Set Water Content for Compensation (Command H2O)
50
Set Carbon Dioxide Content for Compensation (Command CO2)
51
Set Several/All Ambient Parameters with One Single Command (Command ENV)
51
Display/Set Output Parameters (Command OUT_PARAMS)
52
Scaling and Setting the Analog Output
52
Checking the Analog Output
53
Display/Set Relay Operating Mode (Command RELAY_MODE)
53
Display/Set Relay Switching Point (Command RSEL)
53
Relay Operation
53
Set Test Current for Analog Output (Command ITEST)
53
Device Information and Other General Commands
54
Display Device Information (Command ?)
54
Display Device Information with Overwriting in POLL Mode (Command ??)
54
Display Measuring Parameters (Command CALCS)
54
Display Calibration Information (Command CINFO)
55
Display Status of Display Range (Command DB)
55
List Commands (Command HELP)
55
Display Output Status (Command OUT)
56
Display Status of Laser Temperature Controller (Command LTC).56
56
Display All Changeable Parameter Values (Command PARAM)
57
Display Statistic Information (Command STATS)
57
Measure Signal Level (Command SIL)
57
Display Product Name and Software Version (Command VERS)
58
Display Status of Submenu Item (Command STATUS)
58
Save Parameters (Command SAVE)
58
Using Memory
58
Display Error Control Status (Command ERR)
59
Display Error Protocol (Command ERRL)
59
Errors
59
Reset (Command RESET)
59
Resetting the Measuring Device
59
Restore Factory Calibration (Command FCRESTORE)
59
Display Error Table (Command ERRT)
60
Display Errors Detected (Command ERRS)
60
5 Setting Ambient Parameters
61
Compensation of Ambient Parameters
61
Background Gas Effects
62
Pressure Compensation
62
6 Adjustment
65
Hardware Preparations
65
Setting up the Gas Supply for Calibration and Adjustment
66
Using Ambient Air
66
Using Bottled Gas
66
Calibration and Adjustment in the Process
67
Connecting the Gas
67
Connections and Systems
67
Adjusting Gas Flow
68
Information on Calibration Gases
68
Calibration
69
Using Ambient Air
69
Using Bottled Gas
70
Adjustment
71
Adjustment Options
71
Adjustment Process
71
One-Point Adjustment Via the Serial Interface (Command COXY1)
72
One-Point Adjustment Using the Keypad (Function CAL1)
73
Adjustment
74
Two-Point Adjustment Via the Serial Interface (Command COXY2)
74
Calibration Data: Pressure Setting (Bar)
75
Connect Ref Gas #2 to Cuvette
75
Gas Temperature (C)
75
Given Oxygen
75
Measured Oxygen Given Oxygen Gas Temperature (C) Ref Path Temperature (C)
75
New Gain
75
Two-Point Adjustment Using the Keypad (Function CAL2)
76
Setting up the Gas Supply
78
TRANSIC111LP Adjustment for Ambient Gas Measurement
78
Calibration
79
Information on Calibration Gases
79
Using Ambient Air
79
Using Calibration Gas
79
Adjustment
80
Adjustment Options
80
Calibration Method
80
Information on Adjustment
80
One-Point Adjustment Via the Serial Interface
81
One-Point Adjustment Via the Serial Interface (Command COXY1)
81
One-Point Adjustment Using the Keypad (Function CAL1)
83
Restoring Factory Calibration
83
Point #1
75
Point #2
75
Ref Path Temperature (C)
75
Ref2
75
7 Maintenance
84
Field Maintenance
84
Assembly and Disassembly
84
Safety Information for Assembly and Maintenance Work
84
Cleaning the Optical Components
85
Cleaning the TRANSIC111LP Filter
87
Cleaning the Filter
88
Spare Parts and Accessories
89
8 Troubleshooting
91
Function Errors
91
Error Control and Error Categories
91
Self-Test
91
TRANSIC111LP Behavior When Errors Occur
91
Error Display
92
Error Table
92
9 Shutdown
94
Safety Information
94
Preparations for Shutdown
94
Switching the TRANSIC111LP off
94
Protecting a Shutdown TRANSIC111LP
94
Disposal
94
Shipping the TRANSIC111LP to SICK
94
10 Specifications
95
Compliances
95
Technical Data
96
Dimensions and Bore Patterns
96
Ambient Conditions
101
Measured Value Recording
101
Dimensions and Mechanics
102
TRANSIC111LP Inputs and Outputs
102
Pressure Suitability
103
Options and Accessories
103
11 Annex
104
Humidity Conversion Table
104
Influence of Background Gases on Oxygen Measurement
105
Type Code TRANSIC111LP
106
Password
107
Advertisement
Advertisement
Related Products
SICK TRANSIC Extractive
SICK TRANSIC Extractive TRANSIC151LP
SICK TR10 Lock
SICK TR4
SICK TriSpector1008
SICK TriSpector1030
SICK TR110 Lock
SICK TriSpectorP1000
SICK TriSpectorP1008
SICK TriSpectorP1030
SICK Categories
Accessories
Security Sensors
Measuring Instruments
Scanner
Barcode Reader
More SICK Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL