Sign In
Upload
Manuals
Brands
Shimadzu Manuals
Security Sensors
RID-10A
User Manuals: Shimadzu RID-10A Index Detector
Manuals and User Guides for Shimadzu RID-10A Index Detector. We have
1
Shimadzu RID-10A Index Detector manual available for free PDF download: User Manual
Shimadzu RID-10A User Manual (113 pages)
Brand:
Shimadzu
| Category:
Security Sensors
| Size: 2 MB
Table of Contents
Precautions for Safety Operation
3
Warning Labels on the Equipment
4
Precautions on Installation Site and Handling of the Unit
5
Mechanism of Static Electrical Discharge Accident (Example)
7
Occurrence of Static Electricity by Friction between Solid and Liquid
7
Precautions on Static Electricity
7
Conditions Which May Cause Accidents
8
Preventive Measure 1
8
Preventive Measures against Accidents
8
Anti-Static Electricity Measures for Vessel
9
Preventive Measure 2
9
Preventive Measure 3
9
Preventive Measure 4
9
Preventive Measure 5
10
Table of Contents
11
Features
13
General Information
13
Outline
13
Outline
14
Features
15
Principle of Measurement
16
Signal Processing in Mode a
16
Principle of Measurement
17
Signal Processing in Mode L (an Optional Flow Selection Block Is Necessary)
17
Signal Processing in Mode P
17
Flow Schematic
18
Chapter 2 Parts List
19
Parts and Accessories
20
Component Location and Function
21
Front View
21
Interior of Front Cover. Right Side
21
Rear View
21
Front View
22
Interior of Front Cover, Right Side
23
Rear View
24
Chapter4 Installation
25
Basic Installation Requirements
25
Example of System Layout
25
Stacking Modules
25
Electrical Connections
25
Plumbing Connections
25
Connecting the Recorder and Integrator
25
Connecting the Drain Tube for Solvent Leakage
25
Basic Installation Requirements
26
Example of System Layout
27
Stacking Modules
28
Electrical Connections
29
Connection to Outlet
29
Grounding
29
Plumbing Connections
30
Flow Line in the System
30
Connecting the Solvent Delivery Pump and Manual Injector
30
Connecting Injector and Column
31
Connecting Detector and Column
32
Detector Outlet Side Piping
33
Fixing the Tubing
34
Connecting the Recorder and Integrator
35
Connection with Recorder
35
Connecting with Chrornatopac (Integrator)
36
Connecting the Drain Tube for Solvent Leakage
37
Connecting Liquid Leak Tube LC-10A System
37
Operation
38
Precautions for Operation
39
Fundamentals of Operation
40
Turning Power on
40
Display Unit
41
Keyboard
41
STD-Func Keys
42
Shift-Func Keys
42
Edit Keys
43
Basic Operation
43
To Avoid Trouble Caused by Bubbles
44
Setting the Measurement Mode (Example)
44
Fundamentals of Operation
44
Setting Measuring Range (Example)
45
Changing the Range
46
Zero Adjustment of Recorder before Starting Analysis
48
Setting the RESPONSE
48
Plumbing of the Flow Selection Block
50
Usage of each Mode
50
Changing the Measurement Mode
50
Drain Tube
51
Tubing to Use
51
Changing the Tubing Connection
51
Plumbing of the Flow Selection Block
51
Tubing Connection in the Largescale Preparative Mode
52
Creating and Executing Time Programs
53
Command List
53
Setting the RNGA at Decimal Number
53
Execution of RNGA and RNGP
53
Explanation of Display Screen
54
Creating and Executing T I E Programs
54
Flow of Setting
55
Deleting a Step (Example)
56
Start and Stop
56
LOOP Command
57
Additional Functions (AUX FUNC)
58
CELL TEMP (Cell Temperature Setting)
59
ACT TEMP (Monitors Actual Cell Temperature)
59
AUX RANGE (Integrator Output Full Scale)
59
EVENT (Event Output Terminals)
59
EXT-S (External Starts)
60
MONIT-TIME (Monitors Program Elapsed Time)
60
LAMP TIME (Monitors the Lamp Lit Time)
60
Additional Functions (AUX-FUNC)
60
CLOSE KEY (Prohibition of Key Input)
61
ADRS (Remote Address)
61
LOCAL (Setting of the Local Mode)
61
LAMP VOLT (Lamp Voltage)
61
SPAN L (Span Factor I N Mode L)
62
Initial Performance Test
63
System Performance Check
63
System Performance Check
64
Example of Analysis Result
65
Example of Chromatogram
66
Control from the External Equipment
67
Connection with System Controller SCL-1OA
67
Control Form the SCL-IOA
67
Connecting External Input and Output Terminals
67
Connection with System Controller SCL-10A
68
Control from the SCL-10A
69
Power on and CONFIG Screen
69
Setting Initial Parameters
70
Main Menu Screen
70
DET CONTROL Screen
71
Parameter Summary
72
Time Program
73
Command Summary for Time Program
74
Connecting External Input and Output Terminals
76
T.b. 2
77
Cleaning the Flow Lines
78
Chapter 8 Maintenance 8.1 Cleaning the Flow Lines
78
Cleaning the Flow Lines
79
Span Adjustment
80
When Span Adjustment Is Performed Using the Chromatopac
80
Span Adjustment
81
When Span Adjustment Is Performed Using the LC Workstation
82
Example 1 (CLASS-VP)
82
Example 2 (CLASS-Lclo)
82
Replacement of Fuse
84
Periodical Cleaning
85
Performance Verification
86
Component Validation
87
Frequency for Executing Hardware Validation
87
Validation Item
87
Validation Procedure
87
Test Procedures of Stand-Alone Unit
88
Checking the Lamp Lit Time
88
Checking the Lamp Intensity
88
Checking the Temperature Control System
88
Checking the Span
89
Test Procedure Controlled from the SCL-10A
90
Component Validation
91
Component Validation
93
System Validation
94
Test Procedure of Lsocratic LC System
94
System Validation
95
Troubleshooting
98
Symptoms, Causes and Remedies
99
List of Error Messages
101
System Error (Failure of the Main Unit)
101
Specifications
102
Erratum in the Instruction Manual
104
Replacement Parts
105
Consumables and Repair Parts
105
Consumables and Repair Parts
106
Optional Parts
108
Reference
109
Solvent Characteristics
110
Advertisement
Advertisement
Related Products
Shimadzu RF-20A
Shimadzu RF-20AXS
Shimadzu R-300
Shimadzu RC-300
Shimadzu ECD-2010 Exceed
Shimadzu FPD-2010
Shimadzu GC-2010
Shimadzu SPD-16
Shimadzu SPD-20A
Shimadzu SPD-20AV
Shimadzu Categories
Laboratory Equipment
Measuring Instruments
Scales
Security Sensors
Controller
More Shimadzu Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL