Seneca T201DCH100-MU Manuals
Manuals and User Guides for Seneca T201DCH100-MU. We have
3
Seneca T201DCH100-MU manuals available for free PDF download: User Manual, Installation Manual
Seneca T201DCH100-MU User Manual (26 pages)
AC/DC TRUE RMS or DC BIPOLAR CURRENT TRANSFORMER WITH MODBUS RTU PROTOCOL AND ANALOG/DIGITAL OUTPUT
Brand:
Seneca
| Category:
Transformer
| Size: 0 MB
Table of Contents
Table of Contents
3
Device Description and Intended Use
4
Description
4
Features
4
Configuring the Device
5
Dip Switch Configuration
6
Loading Configuration from Flash
6
Setting the RS485 Modbus RTU Station Address
6
Setting the RS485 Baud Rate
7
Setting the Rms/Bipolar Mode and 50% - 100% Full Scale
7
Modbus Rtu Protocol
9
Modbus RTU Function Code Supported
9
Modbus Register Table
10
0-Based" or "1-Based" Modbus Addresses
11
Modbus Addresses with "0-Based" Convention
12
Modbus Addresses with "1 Based" Convention (Standard)
12
Bit Convention Within a Modbus Holding Register
13
MSB and LSB BYTE CONVENTION WITHIN a MODBUS HOLDING REGISTER
13
Representation of a 32-Bit Value in Two Consecutive Modbus Holding Registers
13
Type of 32-Bit Floating Point Data (Ieee 754)
14
T201DCH-MU: MODBUS 4Xxxx HOLDING REGISTERS TABLE (FUNCTION CODE 3)
15
Full Configuration with Easy Setup
20
Easy Setup Menu
20
Creating a Project Configuration
21
Testing the Device
25
The Datalogger
25
Advertisement
Seneca T201DCH100-MU User Manual (25 pages)
AC/DC TRUE RMS or DC BIPOLAR CURRENT TRANSFORMER WITH MODBUS RTU PROTOCOL AND ANALOG/DIGITAL OUTPUT
Brand:
Seneca
| Category:
Transformer
| Size: 0 MB
Table of Contents
Table of Contents
3
Device Description and Intended Use
4
Description
4
Features
4
Configuring the Device
5
Dip Switch Configuration
6
Loading Configuration from Flash
6
Setting the RS485 Modbus RTU Station Address
6
Setting the Rms/Bipolar Mode and 50% - 100% Full Scale
7
Modbus Rtu Protocol
9
Setting the RS485 Baud Rate
7
Modbus RTU Function Code Supported
9
Modbus Register Table
10
0-Based" or "1-Based" Modbus Addresses
10
Modbus Addresses with "0-Based" Convention
12
Modbus Addresses with "1 Based" Convention (Standard)
12
Bit Convention Within a Modbus Holding Register
13
MSB and LSB BYTE CONVENTION WITHIN a MODBUS HOLDING REGISTER
13
Representation of a 32-Bit Value in Two Consecutive Modbus Holding Registers
13
Type of 32-Bit Floating Point Data (Ieee 754)
14
T201DCH-MU: MODBUS 4Xxxx HOLDING REGISTERS TABLE (FUNCTION CODE 3)
15
Full Configuration with Easy Setup
19
Easy Setup Menu
19
Creating a Project Configuration
20
Testing the Device
23
The Datalogger
24
Seneca T201DCH100-MU Installation Manual (4 pages)
True RMS or DC bipolar AC/DC current transducer, HW2 version
Brand:
Seneca
| Category:
Transducer
| Size: 0 MB
Table of Contents
Module Layout
2
Preliminary Warnings
2
Assembly
2
Technical Specifications
3
Standards
3
Environmental Conditions
3
Assembly
3
Connections
3
Power Supply
3
Communication Port
3
Input
3
Capacity
3
Analogue Output
3
USB Port
4
Setting the DIP-Switches
4
Electrical Connections
4
Advertisement
Advertisement
Related Products
Seneca T201DCH50-MU
Seneca T201DCH300-MU
Seneca T201DCH600-MU
Seneca T201DCH50-M
Seneca T201DCH100-M
Seneca T201DCH300-M
Seneca Categories
Media Converter
Gateway
Control Unit
I/O Systems
Measuring Instruments
More Seneca Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL