Sign In
Upload
Manuals
Brands
SEFRAM Manuals
Voice Recorder
BK Precision DAS60
SEFRAM BK Precision DAS60 Manuals
Manuals and User Guides for SEFRAM BK Precision DAS60. We have
2
SEFRAM BK Precision DAS60 manuals available for free PDF download: User Manual
SEFRAM BK Precision DAS60 User Manual (135 pages)
Brand:
SEFRAM
| Category:
Voice Recorder
| Size: 3 MB
Table of Contents
Table of Contents
6
1 Table of Content
12
2 Important Information
12
Specific Cautions
12
Security Instructions
12
Conformity and Limits of the Device
13
3 Presentation
14
General
14
Description
15
Connection
15
Touch Screen
16
Description of the Title Bar
16
Description of the Channel Validation Window
17
Description of the Network Analysis Window
18
Main Menu
20
Update of the Internal Software
22
4 SETUP and PRECAUTIONS of USE
23
Loading of the Recording Paper
23
Precautions for Storage of the Recordings
23
Setup
24
Configuration at Power-Up
24
Voltage Measurement
25
Temperature Measurement with a Thermocouple
25
Temperature Measurement with Pt100/Pt1000
25
Current Measurement
25
Connection of the Ground
26
Routine Maintenance
26
Battery
26
Offset Calibration
27
Default Calibration
28
Screen Brightness
28
Locking of the Recorder
28
User Mode
28
5 Use
29
Description of the Various Modes
29
Setup Menu
30
Channels Menu
31
Analog Channels
32
Type of Measurement ΔV/Δt
33
Type of Measurement ƩV.dt
35
Additional Functions between Channels
36
Logic Channels
37
Validation of the Channels
38
Direct Display » Key
39
Real Time On-Screen Display of the Measurements
39
XY Display
40
Digital Display
41
Trigger » Menu
43
Memory Output » Key
44
Record » Key
45
Screen Copy
46
6 Triggers
47
Analog Channel Trigger
48
Single Threshold
48
Multiple Thresholds
49
Parasites
50
Trigger on Logic Channels
51
7 Mathematical Calculations
52
Definitions
52
Types of Calculations
53
8 Direct Mode
56
Launching the Printing
56
Configuration of Print
58
Relaunching the Printing
59
Writing Information
59
9 Memory Mode
60
Setup and Start of the Data Acquisition
60
Sampling Period
62
Internal Memory, Blocks
62
Trigger Position
62
Double Trigger Mode
63
Recording
64
Memory Output
66
10 Template Mode
67
Setup and Launching of the Data Acquisition
67
Creation of the Template
69
11 File Mode
71
Setup and Triggering of the Data Acquisition
71
Restrictions
72
12 Network Analysis
73
General
73
Network Setup
74
Real Time Display of the Signals
77
Power Analysis Setup
78
Parameter Acquisition File
78
Record Launch
78
Recordable Parameters
80
Record
80
Measurement Process
81
13 File Management
82
General
82
Management of the Configuration Files
83
Save Setup Files
83
Load Setup Files
83
Save Data Acquisitions
83
Recovery of the Data Acquisition Files
85
Operating Software
87
Transfer Via FTP
87
Display under Seframviewer
88
Managing with Seframpilot
89
14 Inputs / Outputs
90
Additional Input/Output Connectors
90
Logic Inputs
91
Use
91
Alarm Outputs
91
Use
92
Power Supply Output
92
Exvoltage Box Input/Output Interface
93
15 Ethernet Interface
95
General
95
WIFI Interface
96
FTP Transfer
97
Managing with VNC
98
Changing the Password
98
External Software VNC Viewer
98
Programming Language
99
Format of the Reception Messages
99
Formats of Emission Messages
100
Standard Instructions
101
Indication of the Status of the Device
102
Structure of the Status Data
102
Service Request Logs
103
Log of Standard Events
105
Log of Alarms
105
Use of the Status Data Structure
106
Dictionary of Programming
108
Configuration
108
Parameters of the Channels
109
Functions of the Channels and between Channels
111
Paper
112
Triggerings
113
Triggers
114
Memory Mode
115
Relaunchs, Real Time Save
116
Launching Plots and Data Acquisitions
116
Diagrams
117
Direct Display
118
Mathematical Functions
118
Memory Output
119
Request of Service
120
Error Messages
120
16 Technical Specifications
121
Isolated Inputs
121
General Characteristics
121
Voltage Recording
121
RMS Recording
122
Temperature Recording
122
Frequency Recording
122
PWM Recording
122
Counting Recording
122
Sampling
123
Bandwidth
123
Additional Inputs / Outputs
124
Logic Channels
124
Alarm Outputs
124
External Power Supply
124
Inputs with Platinum Resistance
124
Triggers
125
Memory Data Acquisition
125
Data Acquisition to File
125
Network Analysis
126
Ranges and Accuracies for Voltage and Intensity
126
Frequency
126
Power Factor
126
Peak and Peak Factor
126
Rate of Harmonics as Calculated in Power Analysis
127
Printer Option
127
Communication Interface
127
Ethernet
127
USB Connectors
127
Display
128
Environment Conditions
128
Weather Conditions
128
Power Supply - Battery
128
Dimensions and Weight
128
Electromagnetic Compatibility, Security
129
Electromagnetic Compatibility According to en 61326-1 and 61326-1-2
129
Security, Insulation Class, Installation Category
130
Accessories
131
Accessories Provided with the Device
131
Accessories and Options
131
Consumables
131
17 Appends
132
Information about the Input Calibers
132
Insulated Voltage Type Inputs
132
Measurement Accuracy for Thermocouple
133
Instant Measurement Accuracy as a Function of the Filters
135
Accuracy Class - Class Index
135
Advertisement
Sefram BK Precision DAS60 User Manual (84 pages)
High Speed Multi-Function Recorders
Brand:
Sefram
| Category:
Measuring Instruments
| Size: 5 MB
Table of Contents
Table of Contents
6
1 Introduction
10
Recording Modes
10
Direct Mode
10
Memory Mode
10
Go No-Go Mode
10
File Mode
10
Power Analysis Mode
10
2 Getting Started
11
Measurement Types
11
Powering the Recorder
11
Connections
11
Analog Inputs
12
Ground the Recorder
12
Thermal Printer
13
Loading Paper
13
Storing Printed Recordings
13
Power-Up Configuration
13
Routine Maintenance
13
Battery
14
To Recharge the Battery
14
Safety Precautions
14
Offset Calibration
14
Default Calibration
15
Screen Brightness
15
Locking of the Recorder
16
User Mode
16
Update of the Internal Software
16
3 Home Screen
17
4 Setup Screen
19
Logic Channels
20
Real Time On-Screen Display of the Measurements
21
XY Display
24
Digital Display
24
Trigger Menu
25
Memory Output Key
25
Record Key
26
Screen Copy
27
5 File Management
28
Save Setup Files
29
Load Setup Files
29
Save Data Acquisitions
29
Recovery of the Data Acquisition Files
30
Transfer Via FTP
30
Display under Seframviewer
31
Managing with Seframpilot
31
6 Direct Mode
33
Launching the Printing
33
Configuration of Print
34
Relaunching the Printing
35
Writing Information
35
7 Memory Mode
36
Setup and Start of the Data Acquisition
36
Sampling Period
37
Internal Memory, Blocks
37
Trigger Position
38
Double Trigger Mode
38
Recording
38
Memory Output
40
8 File Mode
42
Setup and Triggering of the Data Acquisition
42
Restrictions
43
9 Go/No Go Mode
44
Setup and Launching of the Data Acquisition
44
Blocks: Parting of the Internal Memory in Blocks
44
Real Time Save: Simultaneous Record of the Data Acquisition into a File
44
Start: Start Condition of the Data Acquisition
45
Automatic: Automatic Stop When the Block Is Full
45
Creation of the Template
45
Use of the Template
46
10 Power Analysis Mode
47
Power Analysis
47
Network Setup
48
Wiring and Check
49
Fresnel Diagram
50
Warning Messages
50
Recording Additional Channels
50
Real Time Display of the Signals
50
Power Analysis Setup
52
Parameter Acquisition File
52
Record Launch
52
Manual Launch
52
Automatic Trigger
53
Parametric Trigger
53
You Can Select a Stop Condition (Recording Time or Manual Stop)
53
Trigger According to an Inrush
53
In Version 1.1 of the Firmware or Later
54
Trigger According to a Duration or a Date
54
Recordable Parameters
54
Voltage and Current
54
Power
54
Power Factor
54
Record
55
Measurement Process
56
11 Channel Setup
57
Analog Channels
58
Type of Measurement ΔV/ Δt
59
Example
60
Type of Measurement ∫ �� ����
60
Example
61
Additional Functions between Channels
62
12 Triggers
64
Analog Channel Trigger
64
Single Threshold
64
Multiple Thresholds
65
Example
66
Parasites
66
Trigger on Logic Channels
66
13 Math Functions
68
Definitions
68
Types of Calculations
68
Math Functions
69
14 Input - Output
71
Additional Input/Output Connectors
71
Logic Inputs
71
Use
72
Alarm Outputs
72
Power Supply Output
72
External Voltage Box Input/Output Interface
73
15 Ethernet Interface
75
General
75
Crossover Cable
75
WIFI Interface
75
FTP Transfer
76
Managing with VNC
77
Changing the Password
77
External Software VNC Viewer
77
16 Programming
78
Message Format
78
Response Format
78
Message Syntax
78
Header
78
Header Separator
78
One or Several Pieces of Data
78
Data Separator
79
Data
79
Alphanumeric Data
79
Decimal Digital Data
79
Text
79
Message Response Format
79
Syntax
79
Single Header
79
Data
80
Advertisement
Related Products
SEFRAM DAS240
SEFRAM DAS220
SEFRAM BK Precision DAS30
SEFRAM BK Precision DAS50
SEFRAM DBX2000
SEFRAM DAS220BAT
SEFRAM DAS240BAT
SEFRAM Categories
Measuring Instruments
Multimeter
Test Equipment
Controller
Voice Recorder
More SEFRAM Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL