Sign In
Upload
Manuals
Brands
Santerno Manuals
Inverter
SUNWAY M XS
User Manuals: Santerno SUNWAY M XS Solar Inverter
Manuals and User Guides for Santerno SUNWAY M XS Solar Inverter. We have
3
Santerno SUNWAY M XS Solar Inverter manuals available for free PDF download: User Manual, Quick Start Manual
Santerno SUNWAY M XS User Manual (148 pages)
SINGLE-PHASE SOLAR INVERTER
Brand:
Santerno
| Category:
Inverter
| Size: 4 MB
Table of Contents
Table of Contents
3
Index of Figures
5
Index of Tables
6
1 Scope of this Manual
8
2 General Information
8
Description of the Product
8
Benefits
8
Operating Principle
9
Figure 1: Block Diagram of the SUNWAY M XS
9
Main Standard Integrated Functions
10
Attached Documentation
10
3 Basic Installation
11
Caution Statements
11
Checking the Product on Delivery
13
Figure 2: Packaging of the SUNWAY M XS
13
Dataplate
14
Figure 3: Dataplate of the SUNWAY M XS
14
Figure 4: Label Placed on the Metal Enclosure of the Product
16
Transport and Handling
17
Figure 5: Procedure for Opening the Package
18
Figure 6: Package Orientation Symbol
18
Figure 7: Procedure for Removing the SUNWAY M XS from Its Packing
19
Figure 8: SUNWAY M XS Box with Packing Elements
19
Installation
20
Environmental Requirements for the Equipment Storage, Installation and Operation
20
Table 1: Environmental Requirements
20
Wall Mounting
21
Figure 9: Minimum Clearance (in MM) for Proper Ventilation of the SUNWAY M XS
21
Figure 10: Detail of the SUNWAY M XS Bracket with the Fixing Screws
22
Figure 11: the SUNWAY M XS in Upright Position
22
Figure 12: Detail of the SUNWAY M XS with the Side Handles
23
Figure 13: Fastening the SUNWAY M XS to the Wall-Mounting Bracket
23
Electrical Connection
24
Figure 14: Removing the Connector Protective Cover
24
Figure 15: SUNWAY M XS Connectors
25
Table 2: Dimensioning of the MCCB and Cable Specifications
27
Table 3: Specifications of the PV Field
28
Removing the Protective Film from the Display
29
Fiscal Seal
30
Commissioning
30
Figure 17: Slots for the Application of the Fiscal Seal
30
Figure 18: Example of the Start Menu
31
Stopping the Inverter
32
Quick Configuration
32
Setting the Language
33
Figure 19: Language Setting Page
33
Figure 20: Setting the Dialogue Language
33
Setting the Country
34
Figure 21: Country Setting Page
34
Setting the Time Zone
35
Figure 22: Setting the Country
35
Figure 23: Name of the Country Displayed in the Start Menu
35
Figure 24: Time Zone Setting Page
36
Figure 25: Setting the Time Zone
36
Setting the Date and Time
37
Figure 26: Setting the Date
37
Setting the Currency
38
Figure 27: Setting the Date
38
Figure 28: Setting the Currency
38
Setting the Feed-In Tariff
39
Figure 29: Setting the Currency
39
Figure 30: Net Metering Setting Page
39
Resetting the History Data
40
Figure 31: Setting the Feed-In Tariff
40
Figure 32: History Data Resetting Page
40
Resetting the Display
41
Figure 33: History Data Resetting Page
41
Figure 34: Display Resetting Page
41
Connectivity
42
Wi-Fi Connectivity
42
Figure 35: Resetting the Display
42
Figure 36: Setting the AD HOC Connectivity
43
Figure 37: Setting the ROUTER Connectivity
44
Figure 38: Selecting the Desired Network
44
Figure 39: Setting the Network Access Password
45
Figure 40: IP Address Assignment Mode
45
Figure 41: Setting the IP Address
46
Figure 42: Setting the Subnet Mask
46
Accessing the Inverter Data
47
Figure 43: Icon of the SUNWAY M XS Application on the Iphone
49
Sunwayportal.it
50
Technical Support
50
Figure 44: Activating the Sunwayportal.it Service
50
Figure 45: Activating the Technical Support Service
50
Connectivity Troubleshooting
51
Datalogging
52
Figure 46: Displaying a Measure Graph
52
Table 4: Logged Variables
53
4 Graphic Interface Module
54
Figure 47: Graphic Touchscreen Display
54
Navigating in the Graphic Interface
55
Navigation Bar
57
Menu Area
57
Figure 49: Example of a Screen
57
Status Bar Area
58
Figure 50: Screen of the Alarms Menu
58
Figure 51: Screen of the Wi-Fi Status Menu
58
Figure 52: Screen of the Inverter Status Menu
59
Display Windows and Data Enter Windows
60
Graph Window
61
Figure 53: Example of a Measure Graph
61
Alphanumeric Keypad Window
62
Figure 54: Example of Alphanumeric Keypad Window
62
List Window
63
Figure 55: Example of a List Window
63
Command Execution Window
64
Description of the Menus
64
Figure 56: Example of a Run Command Window
64
Figure 57: Icons of the Menu Area in the Start Menu
64
Organisation of Measures and Parameters
65
Table 5: Template of the Measure Descriptive Tables
66
Table 6: Template of the Parameter Descriptive Tables
66
Figure 58: Info Menu Tree
67
Info Menu
67
Table 7: Template of the Variable Descriptive Tables
67
Table 8: Info Menu, Field Submenu
68
Table 9: Info Menu, Inverter Submenu
70
Table 10: Info Menu, Grid Submenu
73
Figure 59: Graph Menu
75
Figure 60: Selection Page for the Measure to be Graphically Displayed
75
Graph Menu
75
Figure 61: Steps to Take for the Customization of the Measures to be Graphically Displayed
76
Figure 62: Setting Page of the Default View
76
Figure 63: Setting the Graph Menu as the Default View
77
Connectivity Menu
78
Figure 64: Connectivity Menu Tree
78
Table 11: Connectivity Menu, Wi-Fi Submenu
79
Table 12: Connectivity Menu, Services Submenu
81
Table 13: Connectivity Menu, Serial Communications Submenu
82
Figure 65: Tools Menu Tree
84
Tools Menu
84
Table 14: Tools Menu, Quick Configuration Submenu
85
Figure 66: Tools Menu, Customization Submenu
87
Figure 67: Tools Menu, Advanced Configuration Submenu
90
Table 25: Tools Menu, Commands Submenu
104
Alarms Menu
107
Figure 70: Example of an Alarm Screen
107
Table 26: Alarms Menu
108
Table 27: Measures in the Alarm History
109
Table 28: List of the SUNWAY M XS Alarms
110
Figure 71: ALARM RESET Screen
119
Figure 72: Example of a Status Window
120
Status Menu
120
Figure 73: Example of a Warning
122
Table 29: Status Messages for the SUNWAY M XS Inverters
122
Figure 74: Example of Wi-Fi Status Window
124
Wi-Fi Status Menu
124
5 Advanced Installation
125
Serial Communications
126
General
126
Figure 77: Example of a SUNWAY M XS Connected to a Communication Network
127
Direct Linking
128
Multidrop Connection
128
Figure 78: Multidrop Network with RS485 Connectors
128
Connection
129
Table 31: Specifications of the RS485 Serial Port
129
Communications Protocol
131
Figure 80: Wiring Diagram for the External Termination and Polarization Resistors
131
Specifications of the Serial Communications
132
Usb Connection
132
Multi-Inverter Plants
132
Table 32: Specifications of RS485 Serial Port
132
Connection to the Lv Grid
133
Connection to the MV Grid
133
Figure 81: CAN Connector
133
Power Balance
133
Figure 82: CAN Wiring Diagram
134
Table 33: Recommended Specifications for CAN Connection Cable
134
Figure 83: Wiring Diagram with Elettronica Santerno Solution
135
Table 34: Elettronica Santerno CAN Wiring Solutions
135
Figure 84: Example of the Start Menu with Power Balance Function Activated
136
Power Balance Configuration
136
Figure 85: Power Balance Activation Page
137
Figure 86: Activating the Power Balance Function
137
Figure 87: Phase Setting Page
138
Figure 88: Inverter Resetting Page
139
Grid Interface Protection Autotest
140
Figure 89: RUN Status Page
140
Table 35: Protection Trip Times
141
Table 36: Trip Times
141
Maintenance
142
Figure 90: Example Page of the Autotest Function
142
6 Specifications
143
Table 37: Specifications of the SUNWAY M XS Inverter
143
Power Limiting
144
Dynamic Adjustment of the Mppt Range
146
7 Index
147
Advertisement
Santerno SUNWAY M XS User Manual (124 pages)
SINGLE-PHASE SOLAR INVERTER
Brand:
Santerno
| Category:
Inverter
| Size: 4 MB
Table of Contents
Table of Contents
3
Index of Figures
5
Index of Tables
7
1 Scope of this Manual
8
2 General Information
8
Description of the Product
8
Benefits
8
Operating Principle
9
Main Standard Integrated Functions
9
Figure 1: Block Diagram of the SUNWAY M XS
9
Attached Documentation
10
3 Basic Installation
11
Caution Statements
11
Checking the Product on Delivery
13
Figure 2: Packaging of the SUNWAY M XS
13
Dataplate
14
Figure 3: Dataplates of the SUNWAY M XS
14
Figure 4: Label Placed on the Metal Enclosure of the Product
16
Transport and Handling
17
Figure 5: Procedure for Opening the Package
17
Figure 6: Procedure for Removing the SUNWAY M XS from Its Packing
18
Figure 7: SUNWAY M XS Box with Packing Elements
18
Installation
19
Environmental Requirements for the Equipment Storage, Installation and Operation
19
Table 1: Environmental Requirements
19
Wall Mounting
20
Figure 8: Minimum Clearance (in MM) to Respect for Proper Ventilation of the SUNWAY M XS
21
Figure 9: Detail of the SUNWAY M XS Bracket with the Fixing Screws
21
Figure 10: the SUNWAY M XS in Upright Position
22
Figure 11: Detail of the SUNWAY M XS with the Side Handles
22
Electrical Connection
23
Figure 12: Removing the Cable Cover
23
Figure 13: SUNWAY M XS Connectors
24
Table 2: Dimensioning of the MCCB and Cable Specifications
25
Figure 14: Fixed Element of the Grid Connector
26
Figure 15: Flying Connector for the Connection to the Grid
26
Figure 16: Mounting the Floating Connector for the Connection to the Grid
27
Table 3: Specifications of the PV Field
29
Figure 17: Polarity for String Connection to the Main PV Field and DC-Side Disconnect Switch
30
Figure 18: Removing the Protective Film from the Touchscreen Display
32
Figure 19: Slots for the Application of the Fiscal Seal
33
Commissioning
34
Figure 20: Example of the Start Menu
34
Stopping the Inverter
35
Quick Configuration
36
Setting the Language
36
Figure 21: Language Setting Page
36
Setting the Country
37
Figure 22: Setting the Dialogue Language
37
Figure 23: Country Setting Page
37
Setting the Time Zone
38
Figure 24: Setting the Country
38
Figure 25: Name of the Country Displayed in the Start Menu
38
Setting the Date and Time
39
Figure 26: Time Zone Setting Page
39
Figure 27: Setting the Time Zone
39
Figure 28: Setting the Date
40
Figure 29: Setting the Date
40
Setting the Currency
41
Figure 30: Setting the Currency
41
Figure 31: Setting the Currency
41
Setting the Feed-In Tariff
42
Figure 32: Net Metering Setting Page
42
Figure 33: Setting the Feed-In Tariff
42
Resetting the History Data
43
Figure 34: History Data Resetting Page
43
Figure 35: History Data Resetting Page
43
Resetting the Display
44
Figure 36: Display Resetting Page
44
Figure 37: Resetting the Display
44
Connectivity
45
Wi-Fi Connectivity
45
Figure 38: Inserting the Wi-Fi Transmitter
45
Figure 39: Activating the Wi-Fi Connection
45
Figure 40: Setting the AD HOC Connectivity
46
Figure 41: Setting the ROUTER Connectivity
47
Figure 42: Selecting the Desired Network
47
Figure 43: Setting the Network Access Password
47
Figure 44: IP Address Assignment Mode
48
Figure 45: Setting the IP Address
48
Figure 46: Setting the Subnet Mask
48
Accessing the Inverter Data
49
Figure 47: Setting the Gateway
49
Figure 48: Setting the DNS
49
Sunwayportal.it
51
Figure 49: Icon of the SUNWAY M XS Application on the Iphone
51
Figure 50: Activating the Sunwayportal.it Service
51
Technical Support
52
Figure 51: Activating the Technical Support Service
52
Figure 52: Checking the Technical Support Service
52
Connectivity Troubleshooting
53
Datalogging
54
Figure 53: Displaying a Measure Graph
54
Table 4: Logged Variables
54
4 Graphic Interface Module
55
Navigating in the Graphic Interface
56
Figure 55: Screens of the Graphic Interface Module at Power on
56
Figure 56: Start Menu
56
Figure 57: Example of a Screen
57
Figure 58: Screen of the Alarms Menu
58
Menu Area
58
Navigation Bar
58
Status Bar Area
58
Figure 59: Screen of the Wi-Fi Status Menu
59
Figure 60: Screen of the Inverter Status Menu
60
Display Windows and Data Enter Windows
61
Graph Window
61
Figure 61: Example of a Measure Graph
61
Alphanumeric Keypad Window
62
Figure 62: Example of an Alphanumeric Keypad Window
62
List Window
63
Command Execution Window
63
Figure 63: Example of a List Window
63
Figure 64: Example of a Run Command Window
63
Description of the Menus
64
Figure 65: Icons of the Menu Area in the Start Menu
64
Organisation of Measures and Parameters
65
Table 5: Template of the Measure Descriptive Tables
66
Table 6: Template of the Parameter Descriptive Tables
66
Table 7: Template of the Variable Descriptive Tables
66
Figure 66: Info Menu Tree
67
Info Menu
67
Table 8: Info Menu, Field Submenu
68
Table 9: Info Menu, Inverter Submenu
70
Table 10: Info Menu, Grid Submenu
72
Figure 67: Graph Menu
74
Figure 68: Selection Page for the Measure to be Graphically Displayed
74
Graph Menu
74
Figure 69: Steps to Take for the Customization of the Measures to be Graphically Displayed
75
Figure 70: Setting Page of the Default View
75
Connectivity Menu
76
Figure 71: Setting the Graph Menu as the Default View
76
Figure 72: Connectivity Menu Tree
76
Table 11: Connectivity Menu, Wi-Fi Submenu
77
Table 12: Connectivity Menu, Services Submenu
79
Figure 73: Tools Menu Tree
80
Tools Menu
80
Table 13: Tools Menu, Quick Configuration Submenu
81
Figure 74: Tools Menu, Customization Submenu
83
Figure 75: Tools Menu, Advanced Configuration Submenu
85
Table 21: Tools Menu, Commands Submenu
95
Alarms Menu
98
Figure 78: Example of an Alarm Screen
98
Table 22: Alarms Menu
99
Table 23: Measures in the Alarm History and Event History
99
Table 24: List of the SUNWAY M XS Alarms
100
Figure 79: ALARM RESET Screen
110
Figure 80: Resetting an Alarm
111
Figure 81: Example of a Status Window
111
Status Menu
111
Table 25: Status Messages for the SUNWAY M XS Inverters
112
Figure 82: Example of a Warning
113
Warnings
113
Figure 83: Example of the Wi-Fi Status Window
114
Wi-Fi Status Menu
114
5 Advanced Installation
116
Serial Communications
116
General
116
Direct Linking
116
Connection
116
Table 26: DB9 Connector - RS485 Serial Port
116
Communications Protocol
117
Specifications of the Serial Communications
117
Table 27: Specifications of the RS485 Serial Port
117
Table 28: Specifications of RS485 Serial Port
117
Usb Connection
118
Grid Interface Protection Autotest
118
Figure 84: RUN Status Page
118
Table 29: Protection Trip Times
119
Table 30: Trip Times
119
Maintenance
120
Figure 85: Test Page
120
Removing the Inverter
121
Figure 86: Removing the Grid Connector
121
Figure 87: Pliers to Remove the Quick-Coupling Connectors
121
Figure 88: Removing the Quick-Coupling Connectors
122
Figure 89: Removing the Inverter
122
6 Specifications
123
Table 31: Specifications of the SUNWAY M XS Inverters
123
Santerno SUNWAY M XS Quick Start Manual (29 pages)
SINGLE-PHASE SOLAR INVERTER
Brand:
Santerno
| Category:
Inverter
| Size: 1 MB
Table of Contents
Targhetta Identificativa
3
Guida Rapida
4
Montaggio a Muro
6
Installazione
7
Wall Mounting
12
Wiring Diagram
12
Guide Rapide
14
Plaque Signalétique
14
Fixation Murale
17
Schéma de Raccordement
17
Installation
18
Guía Rápida
24
Placa de Identificación
24
Diagrama de Conexión
27
Instalación
28
Advertisement
Advertisement
Related Products
Santerno SUNWAY SI
Santerno SINUS-0003 2S
Santerno SINUS-0003 2T
Santerno SINUS-0004 5T
Santerno SUNWAY SI-1K-S1
Santerno SUNWAY SI-1.5K-S1
Santerno SUNWAY SI-3K-S2
Santerno SUNWAY SI-3.6K-S2
Santerno SUNWAY SI-4K-S2
Santerno SUNWAY SI-2.5K-S1
Santerno Categories
Inverter
Controller
DC Drives
Media Converter
Control Unit
More Santerno Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL