Sign In
Upload
Manuals
Brands
rotork Manuals
Valve Positioners
YT-3700
rotork YT-3700 Manuals
Manuals and User Guides for rotork YT-3700. We have
2
rotork YT-3700 manuals available for free PDF download: Product Manual
rotork YT-3700 Product Manual (115 pages)
SMART POSITIONER
Brand:
rotork
| Category:
Valve Positioners
| Size: 6 MB
Table of Contents
Table of Contents
2
Introduction
6
General Information for the Users
6
Manufacturer Warranty
6
Explosion Proof Warning (Only for Intrinsic Safety Type Positioners)
7
Product Description
9
General
9
Main Features and Functions
9
Label Description
10
Product Code
15
YT-3700 / 3750 Series Follows Suffix Symbols as Follows
15
YT-3702 Series Follows Suffix Symbols as Follows
16
Product Specification
17
YT-3700 / 3750 Specification
17
YT-3702 Specification
18
Specification of Digital Input, Digital Output
19
Certifications
20
Parts and Assembly
22
Product Dimension
25
Installation
27
Safety
27
Tools for Installation
27
Linear Positioner Installation
28
Safety
28
Standard Lever Type Positioner Installation Steps
29
Rotary Positioner Installation
34
YT-3700R / 3750R Components
34
YT-3702R Remote Sensor Components
35
Rotary Bracket Information (Only YT-3700R / 3750R)
36
Rotary Positioner Installation Steps
37
Connection - Air
38
Safety
38
Supply Pressure Condition
38
Piping Condition
38
Connection - Piping with Actuator
39
Single Acting Actuator
39
Double Acting Actuator
40
Connection - Power
41
Safety
41
Connection
42
Standard Terminals
42
Terminals with Micro-Limit Switch Option (Only YT-3700 / 3750)
44
Terminals with Inductive Proximity Limit Switch Option (Only YT-3700 / 3750)
45
Ground
45
Adjustments
46
Limit Switch Adjustment (Only YT-3700 / 3750)
46
A/M Switch Adjustment
47
Orifice Installment
48
Optional Sub-PCB Installment
49
Installation Steps
49
Maintenance
51
Supply Air
51
Seals
51
Auto Calibration and PCB Operation
52
Warning
52
LCD Display and Buttons
52
LCD Display and Symbols
52
Button and Function
53
Menu Levels
54
RUN Mode Monitor
55
Configuration and Operation
56
Calibration (Calib)
60
Acting Type (SINGLE / Double)
60
Auto Calibration 1 (AUTO 1)
61
Auto Calibration 2 (AUTO 2)
61
Travel Zero (TVL ZERO) and Travel End (TVL End)
62
Manual Operation (man OPER)
63
Manual Operation by Set Position (man SP)
63
Manual Operation by Manipulator Value (man MV)
64
Control Parameters (CTL PARM)
65
Dead Band (Deadband)
65
Forward P Parameter (KP UP) and Reverse P Parameter (KP Dn)
66
Forward Integral Time Parameter (TI UP) and Reverse Integral Time Parameter (TI Dn)
66
Forward D Parameter (Kd UP) and Reverse D Parameter (Kd Dn)
67
GAP Parameter (GAP)
67
GAP P Parameter (GP)
68
GAP I Parameter (GI)
68
GAP D Parameter (Gd)
69
Auto Dead Band Mode (AUTO Db)
70
Performance Mode (PER Stbl / NORM / FAST)
70
Input Configuration (in CFG)
71
Signal Direction (SIG NORM / REVS)
71
Split Range Mode (SPLIT 4.20 / 4.12 / 12.20 / Cst)
72
Custom Split Range Zero (CST ZERO)
72
Custom Split Range End (CST End)
73
Valve Flow Characterization Curves (CHAR LIN / EQ / USER 5P / USER 21P)
73
User Set Characterization 5 Points (USER 5P)
74
User Set Characterization 21 Points (USER 21P)
75
Tight Shut Open (TSHUT OP)
76
Tight Shut Close (TSHUT CL)
77
Target Position Ramp up Rate (RAMP UP) and Target Position Ramp down Rate (RAMP Dn)
78
Digital Input Function (Dif off / FCL / FOP / PSTA / PSTO)
79
Digital Input Logic (DI LOGIC HI / Lo)
80
Output Configuration (out CFG)
81
Position Transmitter Direction (PTM NORM / REVS)
81
Position Transmitter Zero / End (PTM ZERO / End)
82
HART Feedback Direction (HT NORM / REVS)
83
Back Calculation (Backcal off / On)
84
Digital Output Function (Dof off
85
Digital Output Logic (Do LOGIC HI / Lo)
86
Analog Output Function (AOF off
87
Analog Output Logic (AO LOGIC lo / HI)
88
Device Configuration (Dev CFG)
89
Action Setting (ACT REVS / Dir)
89
Linear Interpolation (ITP off / On)
90
Lock of Parameters (Write Protect, W UNLOCK / LOCK)
90
Actual Position View Mode (View Mode, VI NORM / REVS)
91
Polling Address Setting (POL Addr)
91
Factory Reset (Default off / On)
92
Positioner Self-Test (SELFTEST)
93
Diagnosis Mode (Diagnd)
94
Default Alarm Settings
94
Process Status (PS)
96
Device Status (Ds)
97
View Monitoring Counts (VI CNTS)
99
Diagnostic Limit Configuration (LIMT CFG)
100
Reset Alarm Status (RST ALRM off / On)
101
View Event Log (EVT LOG)
102
Partial Stroke Test Record (View PST Result Record, PST RSLT)
103
PST Configuration (PST CFG)
104
Run PST (PST NOW)
105
Periodic PST Test (PST Schedule, PST Schd off / On)
106
Position Information (INFO)
106
Error Codes During Automatic Calibration
108
Status and Alarm Code
109
Main Software Map
112
Intrinsically Installation Drawing
113
FM Certification
113
CSA Certification
114
Advertisement
rotork YT-3700 Product Manual (100 pages)
Smart Positioner
Brand:
rotork
| Category:
Valve Positioners
| Size: 5 MB
Table of Contents
Table of Contents
2
1 Introduction
5
General Information for the Users
5
Manufacturer Warranty
5
Explosion Proof Warning (Only for Intrinsic Safety Type Positioners)
6
2 Product Description
7
General
7
Main Features and Functions
7
Label Description
8
Product Code
13
Product Specification
14
Specification of Digital In, Digital out
15
Certifications
16
Parts and Assembly
18
Product Dimension
20
3 Installation
21
Safety
21
Tools for Installation
21
Linear Positioner Installation
22
Linear Positioner Installation of Standard Lever Type
22
Safety
22
Standard Lever Type Positioner Installation Steps
23
Rotary Positioner Installation
26
YT-3700R / 3750R Components
26
Rotary Bracket Information
27
Rotary Positioner Installation Steps
28
4 Connection - Air
29
Safety
29
Supply Pressure Condition
29
Piping Condition
29
Connection - Piping with Actuator
30
Single Acting Actuator
30
Double Acting Actuator
30
5 Connection - Power
31
Safety
31
Connection
32
Standard Terminals
32
Terminals with Micro-Limit Switch Option
34
Terminals with Proximity Limit Switch Option
35
Ground
35
6 Adjustments
36
Limit Switch Adjustment
36
A/M Switch Adjustment
37
Orifice Installment
38
Plate Type Orifice Installment
38
7 Optional Sub-PCB Installment
39
Installation Steps
39
8 Auto Calibration and PCB Operation
41
Warning
41
LCD Display and Buttons
41
LCD Display and Symbols
41
Button and Function
42
Menu Levels
43
RUN Mode Monitor
44
Configuration and Operation
45
Calibration (Calib)
49
Acting Type (SINGLE / Double)
49
Auto Calibration 1 (AUTO 1)
50
Auto Calibration 2 (AUTO 2)
50
Travel Zero (TVL ZERO) and Travel End (TVL End)
51
Manual Operation (man OPER)
52
Manual Operation by Set Position (man SP)
52
Manual Operation by MV (man MV)
53
Control Parameters (CTL PARM)
54
Dead Band (Deadband)
54
Forward P Parameter (KP UP) and Reverse P Parameter (KP Dn)
55
Forward Integral Time Parameter (TI UP) and Reverse Integral Time Parameter (TI Dn)
55
Forward D Parameter (Kd UP) and Reverse D Parameter (Kd Dn)
56
Auto Dead Band Mode (AUTO Db)
56
Performance Mode (PER)
57
Input Configuration(in CFG)
58
Signal Direction (SIG NORM / REVS)
58
Split Range Mode (SPLIT)
59
Custom Split Range Zero (CST ZERO)
59
Custom Split Range End (CST End)
60
Valve Flow Characterization Curves (CHAR)
60
User Set Characterization 5 Points (U5)
61
User Set Characterization 21 Points (U21)
62
Tight Shut Open (TSHUT OP)
63
Tight Shut Close (TSHUT CL)
64
Target Position Ramp up Rate (RAMP UP) and Target Position Ramp down Rate (RAMP Dn)
65
Digital Input Function (Dif)
67
Digital Input Logic (DI LOGIC)
67
Output Configuration (out CFG)
68
Position Transmitter Direction (PTM NORM / REVS)
68
Position Transmitter Zero / End (PTM ZERO / End)
69
HART Feedback Direction (HT NORM / REVS)
70
Back Calculation (Backcal off / On)
71
Digital Output Function (Dof)
72
Digital Output Logic (Do LOGIC HI / Lo)
73
Analog Output Function (AOF)
74
Analog Output Logic (AO LOGIC lo / HI)
75
Device Configuration (Dev CFG)
76
Action Setting (ACT)
76
Linear Interpolation (ITP off / On)
77
Lock of Parameters (Write Protect, W UNLOCK / LOCK)
77
Actual Position View Mode (View Mode, VI NORM / REVS)
78
Polling Address Setting (POL Addr)
78
Factory Reset (Default off / On)
79
Positioner Self-Test (SELFTEST)
80
Diagnosis Mode (Diagnd)
81
Default Alarm Settings
81
Process Status (PS)
83
Device Status (Ds)
84
View Monitoring Counts (VI CNTS)
86
Diagnostic Limit Configuration (LIMT CFG)
87
Reset Alarm Status (RST ALRM off / On)
88
View Event Log (EVT LOG)
89
Partial Stroke Test Record (View PST Result Record, PST RSLT)
90
PST Configuration (PST CFG)
91
Run PST (PST NOW)
92
Periodic PST Test (PST Schedule, PST Schd off / On)
93
Position Information (INFO)
94
Status and Alarm Code
96
9 Main Software Map
99
Advertisement
Related Products
rotork YT-3750
rotork YT-3100
rotork YT-3300 Series
rotork YT-3350 Series
rotork YT-3303 Series
rotork YT-3301 Series
rotork YT-3702
rotork YT-3302 Series
rotork YT-1200R
rotork YT-1050R
rotork Categories
Controller
Valve Positioners
Industrial Equipment
Switch
Control Unit
More rotork Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL