Sign In
Upload
Manuals
Brands
Rohde & Schwarz Manuals
Measuring Instruments
1300.2502K03
Rohde & Schwarz 1300.2502K03 Manuals
Manuals and User Guides for Rohde & Schwarz 1300.2502K03. We have
2
Rohde & Schwarz 1300.2502K03 manuals available for free PDF download: Quick Start Manual, Service Manual
Rohde & Schwarz 1300.2502K03 Quick Start Manual (179 pages)
Spectrum Analyzer
Brand:
Rohde & Schwarz
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
19
Front and Rear Panel
29
Front Panel View
30
Function Keys on the Front Panel
32
Connectors on the Front Panel
33
Standard Front Panel Connectors
33
Optional Front Panel Connectors
35
Rear Panel View
36
Connectors on the Rear Panel
38
Standard Rear Panel Connectors
38
Optional Rear Panel Connectors
39
Preparing for Use
43
Preparing for Operation
44
Unpacking the Instrument and Its Accessories
45
Checking the Accessories
46
Ship Damage Inspection
46
Warranty
46
Recommended Calibration Interval
46
Preparing the Instrument for Operation
47
Standalone Operation
47
Rackmounting
47
Power Supply Options
48
Instrument Modes
48
Behavior of the ON/STANDBY Key
49
Connecting the AC Power
50
Switching on the Instrument
50
To Switch on the Instrument
50
Performing a Self Alignment and a Self Test
50
To Perform a Self Alignment
50
To Perform a Self Test
51
Checking the Furnished Items
51
To Check the Installed Options
51
Switching off the Instrument
52
To Switch to Standby Mode
52
To Change into off Mode
53
Replacing the Fuses
54
To Replace the Fuses
54
Charging the Battery Pack (Option R&S FSL-B31)
54
Cleaning the Outside
55
Connecting External Devices
55
Connecting USB Devices
55
Connecting an External Monitor
57
R&S FSL Setup
58
Selecting the Frequency Reference
58
Setting the Date and Time
58
To Open the Date and Time Properties Dialog Box
58
To Change the Date
59
To Change the Time
59
Configuring the GPIB Interface (Option R&S FSL-B10)
59
To Display the GPIB Submenu
59
To Set the GPIB Address
59
To Set the ID Response String
60
Setting the Screen Colors
60
To Display the Screen Colors Submenu
60
To Use the Default Color Settings
60
To Use the Predefined Color Set
61
To Define and Use Your Own Color Set
62
Setting the Automatic Display off Function
63
To Activate Automatic Display off
63
To Deactivate Automatic Display off
63
Selecting and Configuring Printers
63
To Configure the Printer and the Printout
64
To Select the Printout Colors
65
LXI Configuration
66
LXI Classes and LXI Functionality
66
LXI Configuration Dialog
67
Default State of the Network Settings
67
LXI Browser Interface
68
LAN Configuration
69
Ping
70
Configuring the LAN Interface
72
Connecting the Instrument to the Network
72
Configuring the Network Card
72
Changing the IP Address and Configuring the Network Protocols (TCP/IP Protocol)
72
To Display the Network Address Submenu
73
To Configure the Network Protocol in a Network Without DHCP Server
73
To Configure the Network Protocol in a Network with DHCP Server
73
Operating System Properties
74
Windows XP Software Approved for the R&S FSL
74
Windows XP Service Packs
75
Login
75
Windows XP Start Menu
75
To Open the Windows XP Start Menu
75
To Return to the Measurement Screen
75
Firmware Update and Installation of Firmware Options
76
Firmware Update
77
To Update the Firmware
77
To Update the Firmware (Via Windows XP)
78
Firmware Options
78
To Activate Firmware Options
78
Basic Operations
79
Information in the Diagram Area
80
Display of Hardware Settings
81
Status Displays
82
Trace Information
83
Enhancement Labels
84
Setting Parameters
85
Keypad
85
Rotary Knob
86
Arrow and Position Keys
87
Softkeys
88
Dialog Boxes
89
To Enter Numeric Parameters
89
To Enter Alphanumeric Parameters
89
To Navigate in Dialog Boxes
91
Specialties in Windows Dialog Boxes
94
How to Use the Help System
94
To Call Context-Sensitive and Non Context-Sensitive Help
94
To Navigate in the Table of Contents
95
To Navigate in the Help Topics (with Front Panel Keys)
95
To Search for a Topic
95
To Change the Zoom
95
To Close the Help Window
95
Basic Measurement Examples
96
Measuring a Sinusoidal Signal
97
Measuring the Level and Frequency Using Markers
97
Increasing the Frequency Resolution
98
Setting the Reference Level
98
Measuring the Signal Frequency Using the Frequency Counter
99
Measuring Harmonics of Sinusoidal Signals
101
Measuring the Suppression of the First and Second Harmonic of an Input Signal
101
Reducing Noise
102
Measuring Signal Spectra with Multiple Signals
104
Separating Signals by Selecting the Resolution Bandwidth
104
Separating Two Signals with a Level of -30 Dbm each at a Frequency Spacing of 30 Khz
105
Measuring the Modulation Depth of an AM-Modulated Carrier (Span > 0)
108
Measuring of AM-Modulated Signals
110
Displaying the AF of an AM-Modulated Signal (Zero Span)
110
Measurements in Zero Span
112
Measuring the Power Characteristic of Burst Signals
112
Measuring the Power of a GSM Burst During the Activation Phase
112
Measuring the Edges of a GSM Burst with High Time Resolution
114
Measuring the Signal-To-Noise Ratio of Burst Signals
116
Signal-To-Noise Ratio of a GSM Signal
116
Measuring of FM-Modulated Signals
118
Displaying the AF of an FM-Modulated Carrier
119
Storing and Loading Instrument Settings
122
Storing an Instrument Configuration (Without Traces)
122
Storing Traces
123
Loading an Instrument Configuration (with Traces)
123
Configuring Automatic Loading
124
Brief Introduction to Remote Control
125
Basic Steps in Remote Control Programming
126
Linking the Remote Control Library for Visual Basic
126
Initialization and Default State
129
Creating Global Variables
129
Initializing the Remote Control Session
129
Initializing the Instrument
130
Switching the Screen Display on and off
130
Configuring the Power Save Function for the Display
131
Sending Simple Instrument Setting Commands
131
Switching to Manual Operation
131
Reading out Instrument Settings
132
Marker Positioning and Readout
132
Command Synchronization
133
Reading Output Buffers
134
Reading Error Messages
134
Detailed Programming Examples
134
Default Setting of the R&S FSL
134
Setting the Remote Control Status Registers
135
Default Settings for Measurements
135
Using Markers and Delta Markers
137
Marker Search Functions, Restricting the Search Range
137
Frequency Counting
139
Working with a Fixed Reference Point
139
Measuring Noise and Phase Noise
140
Reading out Trace Data
142
Storing and Loading Instrument Settings
143
Storing Instrument Settings
144
Loading Instrument Settings
144
Setting the Data Record for Startup Recall
145
Configuring and Starting a Printout
145
Appendix A: Printer Interface
149
Installing Local Printers
149
To Install a Local Printer
149
Appendix B: LAN Interface
153
Configuring the Network
153
To Change the Computer Name
154
To Change the Domain or Workgroup
154
To Operate the Instrument Without a Network
155
To Create Users
155
To Change the User Password
157
To Log on to the Network
158
To Deactivate the Automatic Login Mechanism
158
To Reactivate the Automatic Login Mechanism
159
To Map Network Drives
159
To Disconnect Network Drives
160
To Install a Network Printer
161
To Share Directories (Only with Microsoft Networks)
165
Remote Operation with XP Remote Desktop
166
To Configure the R&S FSL for Remote Operation
166
To Configure the Controller
168
To Set up a Connection to the R&S FSL
172
To End Remote Desktop Control
174
To Restore the Connection to the R&S FSL
175
To Deactivate the R&S FSL Via Remote Operation
175
RSIB Protocol
175
Advertisement
Rohde & Schwarz 1300.2502K03 Service Manual (153 pages)
Spectrum Analyzer
Brand:
Rohde & Schwarz
| Category:
Measuring Instruments
| Size: 5 MB
Table of Contents
Grouped Safety Messages
3
Basic Safety Instructions
4
Informaciones Elementales de Seguridad
7
Shipping the Instrument
17
Ordering Spare Parts
18
Refurbished Modules
18
Internet Site
19
Table of Contents
20
Performance Test
21
Test Instructions
21
Measurement Equipment and Accessories
21
Performance Test R&S FSL
22
Checking Reference Frequency Accuracy
22
Checking Level Accuracy and Frequency Response
22
Checking RF Attenuator
25
Checking Reference Level Switching (if Gain)
27
Checking Noise Display
27
Checking Phase Noise
28
Checking Display Linearity
29
Checking Third Order Intercept Point
31
Performance Test Tracking Generator - R&S FSL Models 13 and
32
Checking Output Level
32
Performance Test Tracking Generator - R&S FSL Model
33
Checking Output Level
33
Performance Test Report R&S FSL
34
Performance Test Report Tracking Generator
43
Measuring Equipment
45
Troubleshooting
46
Repair
51
Instrument Design and Function Description
51
Block Diagram
51
Fig. 3-1 Block Diagram
51
Description of Block Diagram
52
Frontend
52
Fig. 3-2 RF-To-IF Conversion R&S FSL3 / 6
52
Fig. 3-3 RF-To-IF Conversion R&S FSL18
53
Fig. 3-4 Generation of First Local Oscillator Frequency
54
Fig. 3-5 Generation of Second and Third Local Oscillator Frequencies
55
Fig. 3-6 Tracking Generator R&S FSL3/6
56
Fig. 3-7 Tracking-Generator R&S FSL 18, Part 1
57
Fig. 3-8 Tracking Generator R&S FSL18, Part2
58
Processing of Measured Data - Motherboard
59
Spectrum Analysis Using Swept Resolution Filters
59
FFT Bandwidth
59
Fig. 3-9 Processing of Measured Data
59
DC Power Supply (Option R&S FSL-B30)
60
Battery Pack (Option R&S FSL-B31)
60
OCXO Reference (Option R&S FSL-B4)
60
Front Panel
60
Power Supply Module
61
Module Replacement
61
Overview of the Modules
62
Performing a Cold Boot
62
Replacing the Controller A90
63
Opening the Instrument and Removing the Controller
63
Installing the New Controller and Completing the Instruments
64
Putting into Operation
65
Replacing the Lithium Battery on the Controller
66
Opening the Instrument
66
Removing the Lithium Battery
67
Installing the New Battery and Completing the Instrument
67
Putting into Operation
67
Replacing Flash Card A60
68
Opening the Instrument and Removing the Controller and Flash Card
68
Installing the New Flash Card and Completing the Instruments
69
Putting into Operation
69
Replacing the TFT Display
70
Opening the Instrument and Removing the Front Module
70
Removing the LVO Displayconnector
71
Removing the LCD
72
Installing the New LCD and Completing the Instrument
72
Replacing the LVO Displayconnector in the Front Module
73
Opening the Instrument and Removing the Front Module
73
Removing the LVO Displayconnector
74
Installing the New LVO Displayconnector and Completing the Instrument
75
Replacing the Push-Button Board Set in the Front Module
76
Opening the Instrument and Removing the Front Module
76
Removing the Push-Button Board Set
77
Installing the New Push-Button Board Set and Completing the Instrument
78
Check the Push-Button Board Set
79
Replacing the Flexible Switchboard in the Front Module
80
Opening the Instrument and Removing the Front Module
80
Removing the Flexible Switchboard
81
Installing the New Flexible Switchboard and Completing the Instrument
82
Check the Flexible Switchboard
83
Replacing the Encoder Board in the Front Module
84
Opening the Instrument and Removing the Front Module
84
Removing the Encoder Board
85
Installing the New Encoder Board and Completing the Instrument
86
Replacing the Front Connector in the Front Module
87
Opening the Instrument and Removing the Front Module
87
Removing the Front Connector
88
Installing the New Front Connector and Completing the Instrument
89
Replacing the Screened Filter Glass in the Front Module
90
Opening the Instrument and Removing the Front Module
90
Removing the Screened Filter Glass
91
Installing the New Screened Filter Glass and Completing the Instrument
92
Replacing RF Cable W1 or RF Cable W2 (FSL3/6)
93
Opening the Instrument and Removing the Front Module
93
Removing the RF Cable W1 or RF Cable W2
94
Installing the New RF Cable W1 or RF Cable W2 and Completing the Instrument
95
Replacing RF Input Adaptor X1 (R&S FSL18)
96
Opening the Instrument and Removing the Front Module
96
Installing the New RF Adaptor and Completing the Instrument
98
Replacing the Power Supply
99
Opening the Instrument and Removing the Power Supply
99
Installing the New Power Supply
100
Replacing the Fan
101
Opening the Instrument and Removing the Power Supply
101
Installing the New Fan and Completing the Instrument
102
Replacing the DVI Board A95
103
Opening the Instrument and Removing the DVI Board
103
Installing the New DVI Board and Completing the Instrument
104
Replacing the RF Frontend A100
105
Opening the Instrument and Removing the Board
105
Installing the New Frontend Board and Completing the Instrument
106
Replacing the Tracking Generator TG-20Ghz A200 (FSL18, Mod.28)
108
Opening the Instrument and Removing the Board
108
Installing the New TG-20Ghz Board and Completing the Instrument
109
Replacing the Motherboard A10
110
Opening the Instrument
110
Removing Hardware Options and Battery Adapter
110
Removing LPC Cover
111
Removing the Frontend Board
112
Removing the Front Module
113
Disconnecting Cables
114
Removing the Motherboard
114
Installing the New Motherboard
115
Putting into Operation
116
Replacing the Battery Adapter Board
117
Opening the Instrument and Removing the Battery Adapter
117
Installing the New Battery Adapter and Completing the Instrument
118
Replacing the Relais Unit A101 (FSL18)
119
Opening the Instrument and Removing the Relais Unit
119
Installing the New Relais Unit and Completing the Instrument
120
Replacing the Attenuator A102 (FSL18)
121
Opening the Instrument and Removing the Attenuator
121
Installing the New Attenuator and Completing the Instrument
122
Replacing the DC Block A103 (FSL18)
123
Opening the Instrument and Removing the Attenuator
123
Installing the New DC Block and Completing the Instrument
124
Replacing the Swivel Handle
125
Removing the Handle
125
Installing the New Handle
125
Replacing the OCXO Board (Option R&S FSL-B4)
126
Removing the OCXO Board
126
Installing the New OCXO Board and Completing the Instrument
126
Replacing the Additional Interface (Option R&S FSL-B5)
127
Removing the Additional Interface
127
Installing the New Additional Interface and Completing the Instrument
127
Replacing the IEC/IEEE Bus Board (Option R&S FSL-B10)
128
Removing the IEC/IEEE Bus Board
128
Installing the New IEC/IEEE Bus Board and Completing the Instrument
128
Replacing the DC Power Supply (Option R&S FSL-B30)
129
Removing the DC Power Supply
129
Installing the New DC Power Supply and Completing the Instrument
129
Replacing the Battery Pack (Option R&S FSL-B31)
130
Removing the Battery Pack
130
Installing the New Battery Pack and Completing the Instrument
130
Troubleshooting
131
The Following Utilities Are Provided in the R&S FSL for Diagnostic Purposes
131
Measuring Equipment and Accessories
131
Troubleshooting Start-Up Problems
132
Troubleshooting Problems with Boot Process
133
Installing the Options
137
Documents
140
Spare Parts
140
Available Power Cables
140
Spare Parts List
141
Mechanical Drawings
141
List of R&S FSL Parts Including Spare Parts
142
Block Circuit Diagram
152
Advertisement
Related Products
Rohde & Schwarz 1300.2502K13
Rohde & Schwarz 1300.2502K06
Rohde & Schwarz 1300.2502K16
Rohde & Schwarz 1300.2502K18
Rohde & Schwarz 1300.2502K28
Rohde & Schwarz 1300.0045.62
Rohde & Schwarz 1309.6000.64
Rohde & Schwarz 1307.9002K07
Rohde & Schwarz 1309.7007.02
Rohde & Schwarz 1309.6998.02
Rohde & Schwarz Categories
Measuring Instruments
Test Equipment
Portable Generator
Power Supply
Accessories
More Rohde & Schwarz Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL