Sign In
Upload
Manuals
Brands
Riello Manuals
Burner
RL 130/E
Riello RL 130/E Manuals
Manuals and User Guides for Riello RL 130/E. We have
2
Riello RL 130/E manuals available for free PDF download: Installation, Use And Maintenance Instructions
Riello RL 130/E Installation, Use And Maintenance Instructions (44 pages)
Light oil burner, Modulating operation
Brand:
Riello
| Category:
Burner
| Size: 6.01 MB
Table of Contents
Table of Contents
3
Information and General Instructions
5
Information about the Instruction Manual
5
Introduction
5
General Dangers
5
Other Symbols
5
Delivery of the System and the Instruction Manual
6
Guarantee and Responsibility
6
Safety and Prevention
7
Introduction
7
Personnel Training
7
Technical Description of the Burner
8
Technical Data
8
Electrical Data
8
Burner Models Designations
8
Packaging - Weight (Approximate Measurements)
9
Overall Dimensions
9
Standard Equipment
9
Firing Rate
10
Minimum Furnace Dimensions
10
Burner Description
11
Panel Board Description
12
Control Box for the Air/Fuel Ratio (LMV37.4
13
Actuators (SQM33.5
16
Installation
17
Notes on Safety for the Installation
17
Handling
17
Preliminary Checks
17
Operation Position
17
Burner Raising
18
Preparing the Boiler
18
Commercial Boilers
18
Boring the Boiler Plate
18
Length of the Blast Tube
19
Securing the Burner to the Boiler
19
Electrode Adjustment
19
Nozzle
20
Recommended Nozzles
20
Nozzle Assembly
20
Choice of Nozzle
20
Adjusting the Nozzle Flow Rate
21
Eccentric Setting
21
Combustion Head Setting
22
Burner Refitting
22
Light Oil Supply
23
Hydraulic Connections
24
Hydraulic System Layout
24
Pump
25
Pump Priming
25
Electrical Wiring
26
Supply Cables and External Connections Passage
27
Thermal Relay Calibration
28
Electro-Mechanical Thermal Relay
28
Electronic Thermal Relay
28
Motor Connection at 208-230 or 460V
29
Motor Connection at 575V
29
Reversible Direction
29
Start-Up, Calibration and Operation of the Burner
30
Notes on Safety for the First Start-Up
30
Burner Calibration
30
Combustion Head Setting
30
Nozzle Adjustment
30
Electrode Position
30
Pump Adjustment
30
Burner Start-Up
30
Final Calibration of the Pressure Switch
31
Air Pressure Switch
31
Maximum Oil Pressure Switch
31
Flame Signal Measurement
32
Final Checks (with the Burner Working)
32
Maintenance
33
Notes on Safety for the Maintenance
33
Maintenance Programme
33
Maintenance Frequency
33
Checking and Cleaning
33
Fuel Pump And/Or Couplings Replacement
34
Safety Components
35
Opening the Burner
36
Closing the Burner
36
A Appendix - Spare Parts
37
Appendix - Accessories
40
Appendix - Burner Start up Report
41
Advertisement
Riello RL 130/E Installation, Use And Maintenance Instructions (44 pages)
Light oil burners
Brand:
Riello
| Category:
Burner
| Size: 3.27 MB
Table of Contents
Table of Contents
3
Information and General Instructions
5
Information about the Instruction Manual
5
Introduction
5
General Dangers
5
Other Symbols
5
Delivery of the System and the Instruction Manual
6
Guarantee and Responsibility
6
Safety and Prevention
7
Introduction
7
Personnel Training
7
Technical Description of the Burner
8
Technical Data
8
Burner Models Designations
8
Electrical Data
9
Packaging - Weight (Approximate Measurements)
10
Overall Dimensions
10
Standard Equipment
10
Burner Description
11
Panel Board Description
12
Firing Rates
13
Procedure to Refer Burner Operating Condition in High Altitude Plants
14
Minimum Furnace Dimensions
15
Control Box for the Air/Fuel Ratio (LMV37.4
16
Actuators (SQM33.5
19
Installation
20
Notes on Safety for the Installation
20
Handling
20
Preliminary Checks
20
Operation Position
20
Securing the Burner to the Boiler
21
Boring the Boiler Plate
21
Length of the Blast Tube
21
Combustion Head Pre-Setting (RL 130/E)
22
Nozzle
22
Recommended Nozzles
22
Nozzle Assembly
22
Choice of Nozzle
23
Adjusting the Nozzle Flow Rate
23
Pressure Controller
23
Electrode Adjustment
24
Combustion Head Setting
24
Hydraulic System
25
Fuel Supply
25
Hydraulic Connections
26
Hydraulic System Layout
26
Pump
27
Oil Pressure Switch
27
Electrical Wiring
28
Supply Cables and External Connections Passage
28
Thermal Relay Calibration
29
Electro-Mechanical Thermal Relay
29
Electronic Thermal Relay
29
Motor Connection at 208-230 or 460V
30
Motor Connection at 575V
30
Reversible Direction
30
Start-Up, Calibration and Operation of the Burner
31
Notes on Safety for the First Start-Up
31
Burner Calibration
31
Combustion Head Setting
31
Oil Pressure Switch
31
Nozzle Adjustment
31
Electrode Position
31
Pump Adjustment
31
Burner Start-Up
31
Final Calibration of the Pressure Switch
32
Air Pressure Switch
32
Maximum Oil Pressure Switch
32
Flame Signal Measurement
33
Final Checks (with the Burner Working)
33
Maintenance
34
Notes on Safety for the Maintenance
34
Maintenance Programme
34
Maintenance Frequency
34
Checking and Cleaning
34
Fuel Pump And/Or Couplings Replacement
35
Opening the Burner
36
Closing the Burner
36
Advertisement
Related Products
Riello RL 130
Riello RL 130/M
Riello RL 190
Riello RL 190/M
Riello RL 100/M
Riello RL 10 BLU
Riello RL 100 HS
Riello RL 190/E
Riello RL 100/E
Riello RL 190/M TL
Riello Categories
Burner
Boiler
Indoor Fireplace
UPS
Water Heater
More Riello Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL