Resol DeltaSol CS/2 Manuals
Manuals and User Guides for Resol DeltaSol CS/2. We have
2
Resol DeltaSol CS/2 manuals available for free PDF download: Owner's Manual, Manual
Resol DeltaSol CS/2 Manual (32 pages)
Solar controller
Brand:
Resol
| Category:
Controller
| Size: 2 MB
Table of Contents
MEDT X* Antifreeze Type
1
SEN X* VFD Allocation
2
Table of Contents
3
1 Overview
4
2 Installation
5
Mounting
5
Electrical Connection
5
VFD Grundfos Direct Sensor
6
PWM Output
6
Data Communication / Bus
6
Terminal Allocation
7
3 Operation and Function
9
Buttons
9
4 System-Monitoring-Display
9
Flashing Codes
10
5 Commissioning
11
6 Channel Overview
13
Display Channels
13
ODB Filling Time Active
13
COL X Temperature Collector S1
13
TST X Temperature Store S2
13
Tstt S3
13
S3 X Temperature Sensor 3 S3
14
S4 X Temperature Sensor 4 S4
14
N % X Speed R1
14
Adjustment Channels
15
Hp X Operating Hours R1
15
DT O X Switch-On Temperature Difference R1 6.0 K [12.0 °Ra]
15
DT F X Switch-Off Temperature Difference R1 4.0 K [8.0 °Ra]
15
DT S X Set Temperature Difference R1 10.0 K [20.0 °Ra]
16
RIS X Rise R1 2 K [4 °Ra]
16
Pum
16
Nmx X Maximum Speed R1 100
17
Maximum Store Temperature
17
OSEM X Store Emergency Shutdown Option off
17
Collector Emergency Temperature 130 °C [270 °F]
17
EM X Collector Emergency Temperature if ODB Is 95 °C [200 °F]
17
Occ
18
CMX X* Maximum Collector Temperature 110 °C [230 °F]
18
Osyc
18
DTCO X* Switch-On Temperature Difference Cooling 20.0 K [40.0 °Ra]
18
DTCF X* Switch-Off Temperature Difference Cooling 15.0 K [30.0 °Ra]
18
OSTC X Store Cooling Option off
19
OHOL X* Holiday Cooling Option off
19
THOL X* Holiday Cooling Temperature 40 °C [110 °F]
19
OCN X Collector Minimum Limitation Option off
19
CMN X* Collector Minimum Temperature 10 °C [50 °F]
19
OCF X Antifreeze Option off
19
CFR X* Antifreeze Temperature 4.0 °C [40.0 °F]
19
GFD X Grundfos Direct Sensor™ off
20
OHQM X Heat Quantity Measurement Option off
20
FMAX X* Maximum Flow Rate 6.0 L/Min
20
MED% X* Antifreeze Concentration
21
Propylene or Ethylene Glycol)
21
Odb
21
Tdto X* ODB Switch-On Condition - Time Period 60 S
22
Tfll X* ODB Filling Time 5.0 Min
22
Tstb X* ODB Stabilisation Time 2.0 Min
22
Auto
22
UNIT X Temperature Unit °C
23
7 Troubleshooting
24
8 Accessories
27
Sensors and Measuring Instruments
28
Vbus ® Accessories
28
Interface Adapters
28
9 Index
29
Advertisement
Resol DeltaSol CS/2 Owner's Manual (32 pages)
Brand:
Resol
| Category:
Inverter
| Size: 2 MB
Table of Contents
Application Examples
1
Table of Contents
3
1 Installation
5
Mounting
5
Electrical Connection
6
VFD Grundfos Direct Sensor
7
PWM Output
7
Data Communication / Bus
7
Terminal Allocation
8
Channel Description
10
2 Operation and Function
11
Push Buttons
11
System-Monitoring-Display
11
Flashing Codes
12
3 Commissioning
13
4 Channel Overview
15
Display Channels
15
Adjustment Channels
17
5 Troubleshooting
27
Various
28
6 Accessories
30
Advertisement
Related Products
Resol DeltaSol BS/4 V2
Resol DeltaSol CS/4
RESOL DeltaSol C/3
Resol DeltaSol C/4
RESOL DeltaSol C2
Resol DeltaSol C/1
Resol CS-I
Resol DeltaSol BS/4
RESOL DeltaSol Pool
Resol DeltaSol BS
Resol Categories
Controller
Control Unit
Measuring Instruments
Water Pump
Adapter
More Resol Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL