Sign In
Upload
Manuals
Brands
ProteinSimple Manuals
Laboratory Equipment
Maurice C
ProteinSimple Maurice C Manuals
Manuals and User Guides for ProteinSimple Maurice C. We have
1
ProteinSimple Maurice C manual available for free PDF download: User Manual
ProteinSimple Maurice C User Manual (508 pages)
Brand:
ProteinSimple
| Category:
Laboratory Equipment
| Size: 19 MB
Table of Contents
Table of Contents
3
Let's Get Started
11
Maurice Systems
12
Welcome
12
Chapter 2 Getting Your Lab Ready
13
Introduction
14
Space Requirements
14
Physical Specifications
15
Electrical Requirements
15
Environmental Requirements
15
Software and Computer Requirements
16
General Guidelines and Information
16
Intended Use
16
Correctly
16
Chapter 3 Maurice
17
Maurice Systems
18
External Components
19
System Door
19
Status Light
20
Internal Components
20
Cartridge Slot
20
Sample and Reagent Platform
21
Rear Panel
24
System Labels
25
Computer Workstation
26
Chapter 4 Compass for Ice Overview
28
Launching Compass for Ice
29
Compass for Ice Overview
29
Changing the Screen View
30
Batch Screen
30
Run Summary Screen
31
Analysis Screen
33
Screen Panes
35
Title Bar
35
Main Menu
35
Instrument Status Bar
35
Screen Tab
36
View Bar
36
Compass for Ice Status Bar
36
Software Menus
36
File Menu
37
Edit Menu
37
View Menu
38
Instrument Menu
38
Window Menu
38
Help Menu
39
Layout
39
Resizing the Main Compass for Ice Window
39
Resizing the Screen Tab
40
Resizing Screen Panes
40
Changing the Location of Screen Panes
41
Layout
41
Software Help
43
Checking for and Installing New Versions of Compass
43
For Ice
43
Viewing Release Notes
43
Viewing the Software Log
44
Compass for Ice Version Information
44
Directory and File Information
45
File Types
46
Chapter 5: Cief Batches
48
Batch Screen Overview
49
Batch Screen Panes
49
Software Menus Active in the Batch Screen
50
Opening a Batch
52
Creating a New Batch
53
Step 1 - Open a Template Batch
53
Step 2 - Assign Your Samples
54
Step 3 - Assign Your Method Parameters
57
Step 4 - Set up Your Injections
61
Step 5 - Setup On-Board Mixing (Optional)
65
Step 6 - Add Programmed Pauses and Stops
68
(Optional)
68
Step 7 - Add Batch Notes (Optional)
70
Step 8 - Modify Default Analysis Parameters
70
(Optional)
70
Step 9 - Save Your Batch
71
Viewing Replicate Injections
72
On-Board Mixing
73
Batch History
76
Making Changes to a Batch
77
Viewing and Editing Batches in Completed Runs
78
Copying and Pasting Injection Names or Sample Ids
79
From Other Documents
79
Importing and Exporting Methods
81
Importing a Method
82
Exporting a Method
82
Batch Reports
83
Chapter 6: CE-SDS Batches
86
Batch Screen Overview
87
Batch Screen Panes
87
Software Menus Active in the Batch Screen
88
Opening a Batch
90
Creating a New Batch
91
Step 1 - Open a Template Batch
91
Step 2 - Assign Your Samples
92
Step 3 - Assign Your Method Parameters
95
Step 4 - Set up Your Injections
97
Step 5 - Add Programmed Pauses and Stops
101
(Optional)
101
Step 6 - Add Batch Notes (Optional)
102
Step 7 - Modify Default Analysis Parameters
102
(Optional)
102
Step 8 - Save Your Batch
103
Viewing Replicate Injections
104
Batch History
105
Making Changes to a Batch
106
Viewing and Editing Batches in Completed Runs
107
Copying and Pasting Injection Names or Sample Ids
108
From Other Documents
108
Importing and Exporting Methods
110
Importing a Method
111
Exporting a Method
111
Batch Reports
112
Running Cief Applications on
116
Maurice and Maurice
116
Before You Throw the Switch
117
Power up
117
Running Cief Applications
117
What You'll Need
117
Step 1: Prep Your Markers, Samples and Reagents
118
Step 2: Prep the Cartridge
122
Step 3: Install the Cartridge
124
Step 4: Load Samples and Reagents
125
Step 5: Create a Batch
127
Step 6: Start the Batch
141
Editing a Running Batch
143
Post-Batch Procedures
145
Checking Your Data
148
Step 1: Select Your Detection Mode
148
Step 2: Check Your Pi Markers
148
Step 3: Checking Sample Peaks
151
Step 4: Assigning Peak Names
154
Chapter 8 Running CE-SDS Applications on Maurice and Maurice S
155
Before You Throw the Switch
156
Power up
156
Running CE-SDS Applications
156
What You'll Need
156
Step 1: Prep Your Internal Standard, Samples and Reagents
157
Internal Standard
157
Step 2: Prep the Cartridge
163
Step 3: Install the Cartridge
165
Step 4: Load Samples and Reagents
167
Step 5: Create a Batch
169
Step 6: Start the Batch
179
Editing a Running Batch
181
Post-Batch Procedures
183
Checking Your Data
187
Step 1: Check Your Internal Standard
187
Step 2: Set Your Molecular Weight (MW)
191
Markers
191
Step 3: Checking Sample Peaks
195
Step 4: Assigning Peak Names
198
Chapter 9: Run Status
199
Run Summary Screen Overview
200
Run Summary Screen Panes
200
Software Menus Active in the Run Summary
202
Screen
202
Opening Run Files
204
Opening One Run File
204
Opening Multiple Run Files
204
Batch Injection Information
205
Injection Flags
207
Run Status Information
207
Viewing the Focus Series (Cief Only)
209
Viewing the Separation (CE-SDS Only)
210
Current and Voltage Plots
211
Run History
213
Viewing Multiple Events
213
Copying History Info
215
Viewing Run Errors
215
Injection Reports
216
Example Analysis and Injection Report: Cief
221
Switching between Open Run Files
223
Closing Run Files
224
Chapter 10 Controlling Maurice, Maurice C. and Maurice S
225
Instrument Control
226
Starting a Run
226
Cleaning
226
Stopping a Run
229
Emergency Stop
230
Status Modes
230
Shutdown
231
Instrument Software (Embedded) Updates
231
Self Test
232
Viewing and Changing System Properties
233
Checking Cartridge Status
234
Instrument Reports
235
Example Instrument Report
237
Viewing Log Files
241
Runs Log
241
Instrument Log
242
Self Test Logs
245
Command Log
247
Chapter 11: CE-SDS Data Analysis
249
Analysis Screen Overview
250
Analysis Screen Panes
250
Software Menus Active in the Analysis Screen
251
Opening Run Files
253
Opening One Run File
253
Opening Multiple Run Files
253
How Run Data Is Displayed
255
Experiment Pane: Batch Injection Information
255
Graph Pane: Electropherogram Data
256
Peaks Pane: Calculated Results
256
Injections Pane: User-Specified Peak Names
259
Viewing Run Data
261
Switching between Samples and Standards Data
261
Views
261
Selecting and Displaying Injection Data
264
Switching between Single and Multiple Views of
267
Injections
267
Hiding Injection Data
269
Data Notifications and Warnings
270
Checking Your Results
271
Group Statistics
272
Using Groups
272
Viewing Sample Injection Groups
273
Viewing Statistics
273
Hiding or Removing Injections in Group
275
Analysis
275
Copying Results Tables and Graphs
276
Copying Results Tables
276
Copying the Graph
276
Saving the Graph as an Image File
276
Exporting Run Files
277
Exporting Results Tables
277
Exporting Raw Sample Electropherogram
277
Data
277
Changing Sample Protein Identification
278
Adding or Removing Sample Data
278
Hiding Sample Data
280
Changing Peak Names for Sample Data
281
Changing the Electropherogram View
282
Autoscaling the Electropherogram
283
Customizing the Data Display
283
Stacking Multiple Electropherograms
289
Overlaying Multiple Electropherograms
290
Zooming
291
Selecting Data Viewing Options
292
Adding and Removing Baseline Points
296
Selecting the Graph X-Axis Range
297
Closing Run Files
299
Analysis Settings Overview
300
Advanced Analysis Settings
302
Internal Standard Settings
302
Advanced Analysis Settings Groups
303
Creating a New Analysis Group
303
Changing the Default Analysis Group
304
Modifying an Analysis Group
305
Deleting an Analysis Group
305
Applying Analysis Groups to Specific Run Data
306
Markers Analysis Settings
308
Markers Settings
309
Markers
309
Standards Analysis Settings Groups
310
Creating a New Standards Group
311
Changing the Default Standards Group
314
Modifying a Standards Group
314
Deleting a Standards Group
314
Applying Standards Groups to Specific Run
315
Data
315
Peak Fit Analysis Settings
317
Range Settings
318
Baseline Settings
319
Peak Find Settings
319
Peak Fit Analysis Settings Groups
320
Creating a New Peak Fit Group
321
Changing the Default Peak Fit Group
323
Modifying a Peak Fit Group
323
Deleting a Peak Fit Group
324
Applying Peak Fit Groups to Specific Run Data
324
Manual Peak Integration
327
Peak Names Settings
331
Peak Names Analysis Settings Groups
331
Creating a Peak Names Group
332
Modifying a Peak Names Group
335
Deleting a Peak Names Group
335
Applying Peak Names Groups to Run Data
336
Injection Reports
338
Example Analysis and Injection Report
340
Importing and Exporting Analysis Settings
343
Importing Analysis Settings
343
Exporting Analysis Settings
343
Chapter 12 Analysis
345
Analysis Screen Overview
347
Analysis Screen Panes
347
Software Menus Active in the Analysis Screen
348
Opening Run Files
350
Opening One Run File
350
Opening Multiple Run Files
350
How Run Data Is Displayed
352
Experiment Pane: Batch Injection Information
352
Graph Pane: Electropherogram Data
352
Peaks Pane: Calculated Results
353
Injections Pane: User-Specified Peak Names
355
Viewing Run Data
356
Switching between Samples and Markers Data
356
Views
356
Selecting and Displaying Injection Data
359
Switching between Single and Multiple Views of
362
Injections
362
Hiding Injection Data
364
Data Notifications and Warnings
365
Checking Your Results
366
Group Statistics
366
Using Groups
367
Viewing Sample Injection Groups
367
Viewing Statistics
368
Hiding or Removing Injections in Group
370
Analysis
370
Copying Results Tables and Graphs
371
Copying Results Tables
371
Copying the Graph
371
Saving the Graph as an Image File
371
Exporting Run Files
372
Exporting Results Tables
372
Exporting Raw Sample Electropherogram
372
Data
372
Changing Sample Protein Identification
373
Adding or Removing Sample Data
373
Hiding Sample Data
375
Changing Peak Names for Sample Data
376
Changing the Electropherogram View
377
Autoscaling the Electropherogram
378
Customizing the Data Display
378
Stacking Multiple Electropherograms
384
Overlaying Multiple Electropherograms
385
Overlaying Fluorescence and Absorbance
385
Electropherograms
385
Zooming
387
Selecting Data Viewing Options
388
Adding and Removing Baseline Points
392
Selecting the Graph X-Axis Range
393
Closing Run Files
395
Analysis Settings Overview
396
Advanced Analysis Settings
398
Pi Markers Settings
398
Advanced Analysis Settings Groups
399
Creating a New Analysis Group
399
Changing the Default Analysis Group
400
Modifying an Analysis Group
401
Deleting an Analysis Group
401
Applying Analysis Groups to Specific Run Data
402
Detection Settings
405
Changing the Detection Method
405
Changing the Detection Exposure
406
Peak Fit Analysis Settings
407
Range Settings
408
Baseline Settings
408
Peak Find Settings
408
Peak Fit Analysis Settings Groups
410
Creating a New Peak Fit Group
410
Changing the Default Peak Fit Group
412
Modifying a Peak Fit Group
412
Deleting a Peak Fit Group
413
Applying Peak Fit Groups to Specific Run Data
413
Manual Peak Integration
416
Peak Names Settings
421
Peak Names Analysis Settings Groups
421
Creating a Peak Names Group
422
Modifying a Peak Names Group
425
Deleting a Peak Names Group
425
Applying Peak Names Groups to Run Data
426
Pi Markers Analysis Settings
429
Pi Markers Analysis Settings Groups
429
Creating a New Markers Group
430
Changing the Default Markers Group
432
Modifying a Markers Group
433
Deleting a Markers Group
433
Applying Markers Groups to Specific Run Data
434
Injection Reports
436
Example Analysis and Injection Report
438
Importing and Exporting Analysis Settings
441
Importing Analysis Settings
441
Exporting Analysis Settings
441
Preferences
443
Chapter 13: Setting Your
444
Customize Your Preferences
444
Enabling Access Control
445
Setting Data Export Options
445
Setting up Automatic Injection Reports
446
Selecting Custom Plot Colors for Graph Overlay
447
Grouping Options
449
Setting up Maurice Systems to Send Tweets
450
Chapter 14 Compass Access Control and 21 CFR Part 11 Compliance
455
Overview
456
Authorization Server
456
Server Administration
457
Adding Non-Admin Users
458
Adding Admin Users
462
Resetting User Passwords
463
Audit Trail
464
Password Policy Settings
466
LDAP Settings
466
Encryption Details
467
Enabling Access Control
468
Logging in to Compass for Ice
469
Locking and Unlocking the Application
470
Resolving Log in Issues
470
Saving Changes
471
Signing Files
472
Instrument Command Log
472
Run File History
475
Troubleshooting Problems and Suggested
475
Solutions
475
Chapter 15 Maintenance and Troubleshooting
477
Cartridge Handling and Care
478
Cief Cartridge
479
CE-SDS Cartridge
480
Maintenance
481
Daily
481
Yearly
481
Changing the Fuse
481
Spare Parts
483
Software Updates
483
Instrument Software (Embedded) Updates
483
Frequently Asked Questions: Cief Applications
484
Frequently Asked Questions: CE-SDS Applications
488
Troubleshooting
488
Cief Application Troubleshooting
489
CE-SDS Application Troubleshooting
491
Chapter 16: General Information
493
Compliance
494
Safety Guidelines
495
Chemical Hazards
495
Chemical Waste Hazards
496
Waste Production and Disposal
497
Safety Data Sheets
497
Instrument Safety Labels
498
Consumables and Reagents
499
Maurice Cief Consumables, Kits and Reagents
501
Maurice Systems Consumables and Reagents
503
Customer Service and Technical Support
503
Legal Notices
505
Maurice Disclaimer of Warranty
505
License Agreement
505
Advertisement
Advertisement
Related Products
ProteinSimple Maurice
ProteinSimple Maurice S
ProteinSimple Maurice CE-SDS
ProteinSimple AlphaImager Mini
ProteinSimple FluorChem M
ProteinSimple Jess
ProteinSimple NanoPro 1000
ProteinSimple Categories
Laboratory Equipment
More ProteinSimple Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL