Sign In
Upload
Manuals
Brands
Precisa Manuals
Scales
390 Series
Precisa 390 Series Manuals
Manuals and User Guides for Precisa 390 Series. We have
3
Precisa 390 Series manuals available for free PDF download: Service Manual, Manual
Precisa 390 Series Service Manual (132 pages)
Precision Balances
Brand:
Precisa
| Category:
Scales
| Size: 9 MB
Table of Contents
Table of Contents
3
Components - Bestandteile
5
About Spare Parts - über Ersatzteile
5
Balance Groups - Waagengruppen
5
Housing - Gehäuse
6
Weighing Cell - Wägezelle
8
Overall View - Übersicht
8
Flexure Sets - Lagersätze
10
Particular Spare Flexures - Jeweilige Ersatz-Lager
10
Main Board - Hauptprint
11
Power Adapter - Netzadapter
12
Power Cables - Stromkabel
12
Repairs
13
Before Getting Started
13
About Overhauling a Weighing Cell
13
About These Instructions
13
Required Tools
14
Spare Parts
15
Opening the Balance and Removing the Weighing Cell
16
Overhauling the Weighing Cell
25
Adjusting the Symmetry
50
Installing the Weighing Cell
52
Closing the Balance
56
Adjustments
64
Before Getting Started
64
Table of Specifications
64
Placing Loads
64
Operating Notes
64
Adjusting the Corner Load (the Balance Is Closed)
65
Determining the Corner Load Values
65
Preparing the Closed Balance for Corner Load Adjustment
65
Adjusting the Corner Load
66
Setting the Balance to the Service Mode (the Balance Is Closed)
67
Adjusting the Linearity
67
S-Correction
68
Correcting the S-Curve of the Full Range
68
Correcting the S-Curve of the Full Range (Dual Range Balances Only)
68
Notes on S-Correction
69
Adjusting the Internal Reference Weight (CRW)
70
Adjusting the Internal Reference Weight Using a Nominal Weight
70
Adjusting the Internal Reference Weight Using a Calibrated Weight
70
Adjusting the Balance Using Its Internal Reference Weight
71
Adjusting the Draft Shield
71
Adjusting the Bubble Level
71
3.10 Discussion with the Manufacturer
72
3.11 Sending the Balance to the Manufacturer for Repairs
72
Reparatur
73
Vor dem Beginnen
73
Vom Überholen einer Wägezelle
73
Über diese Anleitung
73
Benötigtes Werkzeug
74
Ersatzteile
75
Die Waage Öffnen und die Wägezelle Herausnehmen
76
Die Wägezelle Überholen
85
Die Symmetrie Einstellen
110
Die Wägezelle Einbauen
112
Die Waage Schließen
116
Justierung
124
Vor dem Beginnen
124
Spezifikationstabelle
124
Lasten Auflegen
124
Bedienungshinweise
124
Die Eckenlast Justieren (die Waage ist Geschlossen)
125
Die Eckenlastwerte Bestimmen
125
Die Geschlossene Waage zum Justieren der Eckenlast Vorbereiten
125
Die Eckenlast Justieren
126
Die Waage in den Servicemodus Bringen (die Waage ist Geschlossen)
127
Die Linearität Justieren
127
S-Korrektur
128
Die S-Kurve des Grobbereichs Korrigieren
128
Die S-Kurve des Feinbereichs Korrigieren (nur Zweibereichswaagen)
128
Anmerkungen zur S-Korrektur
129
Das Interne Referenzgewicht Justieren (CRW)
130
Das Interne Referenzgewicht Mittels eines Nominalgewichts Justieren
130
Das Interne Referenzgewicht Mittels eines Kalibrierten Gewichts Justieren
130
Die Waage Mittels Ihres Internen Referenzgewichts Justieren
131
Den Windschutz Justieren
131
Die Libelle Justieren
131
5.10 Rücksprache mit dem Hersteller
132
5.11 die Waage zur Reparatur an den Hersteller Schicken
132
Advertisement
Precisa 390 Series Service Manual (26 pages)
Precision Balance
Brand:
Precisa
| Category:
Scales
| Size: 1 MB
Table of Contents
Table of Contents
3
Components - Bestandteile
4
About Spare Parts - über Ersatzteile
4
Balance Groups - Waagengruppen
4
Housing - Gehäuse
5
Main Board - Hauptprint
7
Power Adapter - Netzadapter
8
Power Cables - Stromkabel
8
Adjustments
9
Before Getting Started
9
Table of Specifications
9
Placing Loads
9
Operating Notes
9
Adjusting the Corner Load (the Balance Is Closed)
10
Determining the Corner Load Values
10
Preparing the Closed Balance for Corner Load Adjustment
10
Adjusting the Corner Load
11
Setting the Balance to the Service Mode (the Balance Is Closed)
12
Adjusting the Linearity
12
S-Correction
13
Correcting the S-Curve of the Full Range
13
Correcting the S-Curve of the Full Range (Dual Range Balances Only)
13
Notes on S-Correction
14
Adjusting the Internal Reference Weight (CRW)
15
Adjusting the Internal Reference Weight Using a Nominal Weight
15
Adjusting the Internal Reference Weight Using a Calibrated Weight
15
Adjusting the Balance Using Its Internal Reference Weight
15
Adjusting the Draft Shield
16
Discussion with the Manufacturer
17
2.10 Sending the Balance to the Manufacturer for Repairs
17
Justierung
18
Vor dem Beginnen
18
Spezifikationstabelle
18
Lasten Auflegen
18
Bedienungshinweise
18
Die Eckenlast Justieren (die Waage ist Geschlossen)
19
Die Eckenlastwerte Bestimmen
19
Die Geschlossene Waage zum Justieren der Eckenlast Vorbereiten
19
Die Eckenlast Justieren
20
Die Waage in den Servicemodus Bringen (die Waage ist Geschlossen)
21
Die Linearität Justieren
21
S-Korrektur
22
Die S-Kurve des Grobbereichs Korrigieren
22
Die S-Kurve des Feinbereichs Korrigieren (nur Zweibereichswaagen)
22
Anmerkungen zur S-Korrektur
23
Das Interne Referenzgewicht Justieren (CRW)
24
Das Interne Referenzgewicht Mittels eines Nominalgewichts Justieren
24
Das Interne Referenzgewicht Mittels eines Kalibrierten Gewichts Justieren
24
Die Waage Mittels Ihres Internen Referenzgewichts Justieren
24
Den Windschutz Justieren
25
Rücksprache mit dem Hersteller
26
3.10 die Waage zur Reparatur an den Hersteller Schicken
26
Precisa 390 Series Manual (4 pages)
Brand:
Precisa
| Category:
Scales
| Size: 0 MB
Advertisement
Advertisement
Related Products
Precisa 390 HF
Precisa 390 HA
Precisa 390 HE
Precisa 390 HM
Precisa 320 XB
Precisa 320 XT
Precisa 360
Precisa 321 Series
Precisa 300 Series
Precisa 350-8182-000
Precisa Categories
Scales
Measuring Instruments
More Precisa Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL