Sign In
Upload
Manuals
Brands
Pfeiffer Vacuum Manuals
Measuring Instruments
QMG 422
Pfeiffer Vacuum QMG 422 Mass Spectrometer Manuals
Manuals and User Guides for Pfeiffer Vacuum QMG 422 Mass Spectrometer. We have
3
Pfeiffer Vacuum QMG 422 Mass Spectrometer manuals available for free PDF download: Manual, Operating Instructions Manual
Pfeiffer Vacuum QMG 422 Operating Instructions Manual (72 pages)
Quadrupole Mass Spectrometer System
Brand:
Pfeiffer Vacuum
| Category:
Laboratory Equipment
| Size: 1 MB
Table of Contents
Validity
2
Table of Contents
3
1 Safety
5
Symbols Used
5
Intended Use
6
Safety Information
6
Liability and Warranty
6
Courses
6
2 Overview
7
QMS 422 Control Unit
8
QMI 422 Control Unit
8
EP 422 Electrometer Preamplifier
8
Family 400 Components
9
Family 125 Components
9
Options
10
3 Technical Data
11
General
11
QMS 422 Control Unit
11
CS 422 Operator Console
11
QMI 422 Control Unit
11
QC 422 Quadruple Controller
12
IS 420 Ion Source Supply
16
EP 422 Electrometer
17
CP 400 Ion Counter Preamplifier
17
HV 420 High Voltage Supply
18
HV 421 High Voltage Supply
18
DI 420 Digital Input
19
DO 420A Digital Output
19
AI 421 Analog Input
20
OH 421 Optical Hub
20
4 Installation
21
Qms/Qmi 422
21
Overall System
21
Ep 422
22
Cp 400
22
Cabling with QMA 400
23
Cabling with QMA 125
24
RS-232-C Interface
25
LAN Interface
26
Installing/Removing Options
28
5 Description
31
Operator Console
31
Functions
33
Parameter List
35
6 Operation
46
Initial Start up
46
Filament Protection
47
Degas
47
Offset Correction
47
Ion Counter
48
Extern Input
48
Simulation
48
Measurement Cycle
49
Electrometer Modes
50
Mass Scan Modes
50
Integral Spectrum
52
Adjust
52
Analog Outputs
55
Switching Functions
58
7 Troubleshooting
60
General
60
Warnings
60
Error Messages
60
Measurement Signal Problems
62
General Problems
63
Service Interventions
64
8 Maintenance
64
9 Decommissioning
64
10 Spare Parts and Accessories
65
Appendix
66
A: Default Parameter Values
66
B: Literature
68
C: Index
69
Declaration of Contamination
70
Declaration of Conformity
71
Advertisement
Pfeiffer Vacuum QMG 422 Operating Instructions Manual (60 pages)
Brand:
Pfeiffer Vacuum
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Product Identification
2
Validity
2
Intended Use
2
Table of Contents
3
1 Safety
5
Symbols Used
5
Personnel Qualifications
5
General Safety Instructions
5
Liability and Warranty
6
2 Description
7
Design
7
Ion Sources
8
Mass Filter
8
Secondary Electron Multiplier
9
Versions
10
Cathode Materials
10
Electron Collimation Magnet
11
90° Deflection
11
Faraday Cup
12
Isolated Design
12
Vacuum Annealed QMA
13
Extraction Hood
13
Beam Deflection Device
13
Differential Pumping
13
3 Technical Data
14
4 Installation
17
Preparation
17
Installing the Electron Collimation Magnets
20
Installation
21
Gas Inlet System
22
Qmh 400/410
22
Ep 422
22
Cp 400
23
Removing / Installing the SEM Connector Plate
23
Mounting the Protective Tubes
23
Cabling
23
5 Operation
24
First Time Operation
24
High Temperature Operation
25
Baking the Analyzer
25
Removing the Connector Plates
26
Mounting the Connector Plates
26
Assessing the Sensitivity
26
Secondary Electron Multiplier SEM
27
Contamination
27
Low Partial Pressures
27
Gain Factor
27
Surface Ions
28
Degas
28
6 Optimization
29
Recommended Operating Modes
29
Test Gas
30
Ion Source Parameters
31
Emission
31
Protection
31
V1 Ionref
31
V2 Cathode
32
V3 Focus
32
V4 Field Axis
32
V5 Extraction
33
V8 Reserve
33
V9 Wehnelt
33
V6 / V7 Deflection
33
Resolution
34
RF Cable Polarity
34
7 Ion Sources
35
Axial Ion Source
35
Crossbeam Ion Source
37
Grid Ion Source
41
Two Lens Ion Optics
43
Crossbeam Ion Source with Two Lens Ion Optics
46
Three Lens Ion Optics
48
Crossbeam Ion Source with Three Lens Ion Optics
51
8 Maintenance and Spare Parts
54
9 Disposal
54
Appendix
55
A: Literature
55
Declaration of Contamination
56
Declaration of Conformity
57
Pfeiffer Vacuum QMG 422 Manual (84 pages)
Quadrupole mass spectrometer system
Brand:
Pfeiffer Vacuum
| Category:
Laboratory Equipment
| Size: 0 MB
Table of Contents
Table of Contents
2
Ion Source Set Number for Filament
2
Important Information
4
Explanation of Symbols
4
Validity
4
Bibliography
4
Description
5
RS-232-C Interface
5
LAN Interface
5
Installation
5
Technical Data
5
Definitions
6
Data Transmission
6
RS-232-C Interface (ASCII)
6
Syntax
7
Communication Protocol (Data Link)
7
Influencing the Measurement by Changing a Parameter
8
Mnemonics
9
Operation Group
11
Ion Src MODE ISM
24
Operation Group
24
Sem Control SEM
24
Type Ity
24
Copy Ics
25
D-Emis Ide
25
D-Prot Idp
25
D-Time Idt
25
Emi-Disp IED
25
Fil1 Is1
25
Fil2 Is2
25
Filam Ifi
25
Begin Cbe
26
Ctrl Isc
26
Cycle FUNCT CFU
26
Cycles Cys
26
End Cen
26
Mode Cym
26
Run-Time CWA
26
Trig Ctr
26
Adj-Typ Ccf
27
Filam Fila-Emi FIE
27
Penning TPE
27
Run / Halt RUN / HALT CRU
27
A-Output AOU
28
ANALOG A-Input AIN
28
Emis Emi-Cur Ecu
28
Trip STATUS T-State TST
28
B-Data MDB
29
Advertisement
Advertisement
Related Products
Pfeiffer Vacuum PrismaPlus QMG 220
Pfeiffer Vacuum QMA 400
Pfeiffer Vacuum QMA 410
Pfeiffer Vacuum QMA 430
Pfeiffer Vacuum QMA 4X0
Pfeiffer Vacuum QMA 125
Pfeiffer Vacuum QMA 4 0 Series
Pfeiffer Vacuum Quadrupole Electronics QME 125-1
Pfeiffer Vacuum Quadrupole Electronics QME 125-2
Pfeiffer Vacuum HIQUAD QMG 700
Pfeiffer Vacuum Categories
Water Pump
Control Unit
Measuring Instruments
Industrial Equipment
Security Sensors
More Pfeiffer Vacuum Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL