Table of Contents
7
Chapter 1. Features and Capabilities
13
Overview
13
Applications
13
Advantages
13
Meter Components
13
Name and Specification Plate
15
Theory of Operation
15
Transit-Time Method
16
Transducers
16
Multipath Design
17
Flow Ranges
17
Specifications
17
Operation and Performance
17
Meter Body
18
Electronics
20
Ordering Information
21
Disclaimer
24
Warnings and Cautions
24
Chapter 2. Installation
27
Installation Guidelines
27
Bill of Materials
27
Mechanical Installation
28
Location
28
Installation Precautions
29
Installing the System
29
Guidelines for Installing Pipe Insulation
30
Making Electrical Connections
31
Removing the Covers
32
Cable Tie-Down Posts
32
Wiring the Line Power
34
Wiring the Serial Port
36
Wiring the Modbus Communications Line (Optional)
36
Wiring the Alarm Relay
37
Wiring the 4-20Ma Analog Inputs (Optional)
38
Wiring the Frequency Output
42
Wiring the 4-20 Ma Analog Output
43
Chapter 3. General Programming
49
Introduction
49
Keypad Features
49
Indicator Lights
50
The Magnetic Stylus
50
Program Menu Options
51
Channel Program
51
Composite Program
51
Advanced Program
51
Unlocking and Locking
52
Unlocking the Sentinel LNG
52
Locking the Sentinel LNG
53
Setting Security
54
Edit Passcodes
54
Security Timeout
54
Set Security
54
Channel Programming
55
Activating a Channel/Path/Chx (Status)
55
Entering Fluid Data (Not Supported at this Time)
56
Entering Signal Parameters
56
Entering Error Limits
58
Composite Programming
59
Entering Fluid Type
59
Entering Signal Parameters
60
Setting up Input Data Feeds
60
Setting up API
61
Configuration
62
Inputs/Outputs
63
Analog Outputs
63
Frequency/Totalizers
63
Alarms
65
Analog Inputs (Additional Option)
66
RTD (Additional Option)
67
Display
67
Calibration
67
User Security
68
Edit Passcodes
68
3.12.2 Security Timeout
68
3.12.3 Set Security
68
Factory Status
68
Chapter 4. Advanced Programming
69
Entering Transducer Parameters
69
Clamp-On Transducers
69
Other Transducers
69
Wetted Transducers
70
Entering Path Data
71
Entering Signal Parameters
71
Entering the Meter Correction (K) Factor
72
Entering Pipe Parameters
74
Entering the Pipe Material
75
Entering Pipe Lining Data
75
Chapter 5. Using Panaview
77
Introduction
77
Wiring the RS232 Interface
77
Establishing Communications with Panaview
77
Adding a Communications Port
77
Adding the Sentinel LNG to the Communications Port
79
Meter Security
83
Meter Properties
83
Program Menu
84
Status Setup
85
Transducer Setup
85
Fluid Setup
90
Path Setup
96
Signal Setup
97
K Factor Setup
97
Error Limits Setup
98
Composite Programs
99
Pipe Setup
99
Fluid Setup
105
Signal Setup
109
K Factors Setup
109
Weight Factors Setup
114
Inputs Setup
114
API Setup
122
Configuration Menu
128
Units Setup
128
Communication Setup
129
Reset Totals
137
Totalizer Errors
138
Input/Output Menu
138
Analog Outputs Setup
139
Frequency/Totals Setup
141
Alarms Setup
149
Slot 1 Setup
158
Slot 2 Setup
165
Display Menu
165
Views Setup
165
5.10.2 Contrast and Backlight
169
5.10.3 Display Mode Setup
169
Calibrate Menu
170
User Menu
172
Edit Passcodes
172
5.12.2 Set Security
173
Factory Menu
174
Checking Versions
174
5.13.2 Confirming Meters
176
Chapter 6. MODBUS Communications
179
Introduction
179
Setting up MODBUS Communications
179
Chapter 7. HART Communications
185
Introduction
185
Wiring the HART Interface
185
Flowmeter Software Setup
186
Product Interfaces
186
Process Interface
186
Host Interface
187
Device Variables
187
Dynamic Variables
191
Status Information
191
Device Status
191
Extended Device Status
191
Additional Device Status
192
Universal Commands
193
Common-Practice Commands
193
Supported Common Practice Commands
193
Burst Mode Commands
194
Catch Device Variable Command
194
Device-Specific Commands
195
Command 181 (0Xb5): Clear Totals
195
Tables
196
HART Engineering Units
196
Performance
198
Sampling Rate
198
7.12.2 Power-Up
198
7.12.3 Device Reset
198
7.12.4 Self-Test
199
7.12.5 Command Response Delay
199
7.12.6 Busy and Delayed Response
199
7.12.7 Long Messages
199
7.12.8 Non-Volatile Memory
199
7.12.9 Operating Modes
199
7.12.10 Write Protection
199
7.12.11 Write Protect Switch
199
7.12.12 Totals Protect Switch
199
Capability Checklist
199
Default Configuration
201
Revision History
201
Chapter 8. Maintenance
203
Calibration
203
Updating Sentinel LNG Instrument Software
203
Checking the Meter Software
207
Trimming 4-20 Ma Using the Keypad
208
Spare Parts
208
Installing Replacement Parts
208
Chapter 9. Troubleshooting
209
Introduction
209
Error Codes
209
E0: no Error
209
E1: Low Signal
209
E2: Soundspeed Error
209
E3: Velocity Range Error
209
E4: Signal Quality Error
210
E5: Amplitude Error
210
E6: Cycle Skip, Acceleration Error
210
E7: Analog Output Error
211
E13: Settle Tracking AGC
211
E14: Tracking Seek Mode
211
E15: Active Tw Error
211
E16: Totalizer Overflow Error
211
E17: Temperature Input Error
211
E18: Pressure Input Error
211
E19: Density Input Error
211
E20: Special Input Error
212
E21: API Error
212
E22: Degraded Performance Error
212
E30: Channel Disabled
212
Displaying Diagnostic Parameters
212
Fluid and Pipe Problems
214
Fluid Problems
214
Pipe Problems
215
Transducer Problems
215
Clamp-On Transducer Problems
215
Audit Trail
216
Audit Log
216
Reading Audit Log Records
217
Formatting and Viewing Log Records
218
Uncertainty in Flow Rate for a Non-Insulated Meter
219
Appendix A. Menu Maps
221
Appendix B. CE Mark Compliance and High Noise Areas
231
Introduction
231
EMC Compliance
231
Appendix C. Data Records
233
Site Data
233
Appendix C. Service Record
237
Introduction
237
Data Entry
237
Diagnostic Parameters
238
Advertisement
Advertisement
Related Products
Panametrics Sentinel LCT
Panametrics Sentinel
Panametrics 910-198E
Panametrics Aurora H2O
Panametrics CGA 351
Panametrics CTF878
Panametrics DewPro MMR31
Panametrics DewPro MMY30
Panametrics DigitalFlow DF868
Panametrics DigitalFlow GC868
Panametrics Categories
Measuring Instruments
Transmitter
Transducer
Industrial Equipment
Analytical Instruments
More Panametrics Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL