Sign In
Upload
Manuals
Brands
OHAUS Manuals
Scales
Explorer EX42022
OHAUS Explorer EX42022 Manuals
Manuals and User Guides for OHAUS Explorer EX42022. We have
4
OHAUS Explorer EX42022 manuals available for free PDF download: Instruction Manual
OHAUS Explorer EX42022 Instruction Manual (164 pages)
Brand:
OHAUS
| Category:
Scales
| Size: 16 MB
Table of Contents
Table of Contents
3
Introduction
7
Description
7
Features
7
Safety Precautions
8
Intended User
8
Installation
9
Unpacking
9
Terminal Setup
10
Installing the Wind Ring, Weighing Platform on Semi-Micro Models
10
Installing the Wind Ring, Weighing Platform on Models EX124
10
Installing the Glass Shelf (on Semi-Micro Models)
12
Installing the Weighing Pan & Wind Shield - Non-Draft Shield Models
12
Selecting the Location
13
Leveling the Equipment
13
Connecting Power
13
Models with AC Adapter
13
Models with AC Power Cord
14
Power on Button on EX12001, EX24001 and EX35001
14
Connecting the Interface
14
Adjusting the View Angle of the Terminal
14
Remote Terminal Operation
15
Separating the Terminal from the Weighing Base
15
Terminal Mounting
15
Initial Calibration
16
Operation
17
Overview of Display, Home Screen
17
Principal Functions and Main Menu
17
Overview of Parts and Features
18
Overview of Parts and Features -Draft Shield Models
19
Overview of Parts and Features - Non-Draft Shield Models
20
Overview of Parts and Features - EX12001, EX24001 and EX35001
21
Overview of Parts and Features - Terminal
22
Functions and Their Icons
23
Standby
23
Printing Data
23
Zero Operation
23
Touchless Sensor Status
23
Autocal
23
Menu
23
More
23
Level Assist
23
Graduations
24
Routine Test
24
Applications
24
Taring a Container
24
Weighing Units
24
Ionizer (Only for EX225D/AD and EX225/AD)
24
Preset Tare
24
Calibration Test
24
Calculator
24
Stopwatch
25
Logout
25
Ionizer (EX225D/AD and EX225/AD Only) and Glass Shelf
25
Application
26
Weighing
27
Edit Settings
27
Application Setup
29
Statistics for Weighing
30
Parts Counting
33
Standard Parts Counting (Default)
33
Application Setup
36
Parts Counting - Check
37
Parts Counting - Fill
38
Statistics for Parts Counting
39
Percent Weighing
41
Edit Settings
41
Application Setup
43
Check Weighing
44
Standard Check Weighing (Default)
44
Edit Settings
44
Application Setup
45
Check Weighing - Nominal/Weight Tolerance Mode
46
Check Weighing - Nominal/Percent Tolerance Mode
47
Display Settings
48
Statistics for Check Weighing
49
Dynamic/Animal Weighing
50
Edit Settings
51
Application Setup
51
Dynamic Weighing - Semi-Auto
52
Dynamic Weighing - Automatic
53
Statistics for Dynamic Weighing
54
Filling
55
Edit Settings
55
Application Setup
56
Statistics for Filling
57
Totalization
59
Totalization - Manual (Default)
59
Application Setup
60
Totalization - Automatic
61
Formulation
62
Free Formulation (Default)
62
Application Setup
63
Recipe Formulation
64
Differential Weighing
67
Item Settings
67
Application Setup
69
Differential Weighing with Auto-Process on
70
Density Determination
71
Measuring the Density of a Solid Using Water (Default)
71
Application Setup
73
Measuring the Density of a Buoyant Material Using Water
74
Measuring the Density of a Solid Using an Auxiliary Liquid
74
Measuring the Density of a Liquid Using a Calibrated Sinker (Not Supplied)
75
Measuring the Density of Porous Material Using Oil
77
Peak Hold
79
Peak Hold - Semi-Automatic (Default)
79
Application Setup
80
Peak Hold - Manual
81
Peak Hold - Automatic
82
Ingredient Costing (Not Available in Semi-Micro Models)
83
Item Settings
83
Application Setup
86
Pipette Adjustment (Not Available in EX12001, EX24001, EX35001)
87
Pipette Adjustment - Manual (Default)
87
Begin Pipette Adjustment Process
89
Application Setup
90
Statistical Quality Control (SQC)
91
Edit Settings
91
Begin the SQC Process
92
Application Setup
93
Fill Weight Variation
95
Edit Settings
95
Begin the Fill Weight Variation Process
97
Application Setup
98
Statistics
99
Secondary Unit
99
Library
100
Creating a Library Record
101
Retrieving a Library Record
101
Deleting a Stored Library Record
101
Additional Features
102
Weigh below
102
Menu Settings
103
Menu Navigation
103
Changing Settings
103
Main Menu
103
Calibration
104
Calibration Sub-Menu
104
Internal Calibration (Autocal™)
104
Automatic Calibration
104
Auto TM Interval (Hours)
105
Autocal™ Adjustment
105
Span Calibration
105
User Calibration
106
Calibration Test
106
User Management
107
User Settings
109
User Settings Sub-Menu
109
Change Password
109
Language
109
Volume
109
Display Settings
109
Functions Configuration
110
Touchless Sensor Setup
110
Draft Shield Light
110
Ionizer (Seconds)
110
Balance Setup
111
Balance Set-Up Sub-Menu
111
Stable Range
111
Filter Level
111
Auto Zero Tracking
111
Audible Signal
111
Auto Tare
112
Gross Indicator
112
Legal for Trade
112
Graduations
112
Internal Calibration
112
Date & Time
113
Applications
114
Turning an Application ON/OFF
114
Weighing Units
114
Units Sub-Menu
114
Turning a Unit ON/OFF
115
Custom Units
115
GLP and GMP Data
116
GLP Data Sub-Menu
116
Header
116
Balance Name
116
Project Name
116
Communication
116
Communication Sub-Menu
116
Device & Print Settings
116
Baud Rate
117
Transmission
117
Handshake
117
Alternate Command
117
Print Output
117
Auto Print
118
Print Calibration Data
118
Print Content
118
Print Layout
120
Data Transfer Function
121
Label Template
122
Save to USB Flash Drive
122
Library
124
Diagnostics
125
Routine Test
125
Level Bubble Light (Not Available in EX12001, EX24001, EX35001)
125
Draft Shield Light (Analytical Models)
125
Sensors
125
Automatic Draftshield Door
125
Data Maintenance
126
Service Mode
126
Factory Reset
127
Factory Reset Sub-Menu
127
Reset Calibration
127
Reset User Settings
127
Reset Balance Setup
127
Reset Application Modes
127
Reset Weighing Units
127
Reset GLP and GMP Data
127
Reset Communication
127
Reset All (Global Reset)
127
Information
128
Using Information
128
Legal for Trade
129
Settings
129
Verification
129
Sealing
129
Printing
130
Connecting, Configuring and Testing the Printer/Computer Interface
130
Printout Examples
131
Minimum Weight
131
Output Format
141
Maintenance
142
Calibration
142
Cleaning
142
Battery Power
142
Troubleshooting
142
Advertisement
OHAUS Explorer EX42022 Instruction Manual (164 pages)
Brand:
OHAUS
| Category:
Scales
| Size: 13 MB
Table of Contents
Table of Contents
3
Introduction
7
Description
7
Features
7
Safety Precautions
8
Installation
9
Unpacking
9
Terminal Setup
10
Installing the Wind Ring, Weighing Platform on Semi-Micro Models
10
Installing the Wind Ring, Weighing Platform on Models EX124
10
Installing the Glass Shelf (on Semi-Micro Models)
12
Installing the Weighing Pan & Wind Shield - Non-Draft Shield Models
12
Selecting the Location
13
Leveling the Equipment
13
Connecting Power
13
Models with AC Adapter
13
Models with AC Power Cord
14
Power on Button on EX12001, EX24001 and EX35001
14
Connecting the Interface
14
Adjusting the View Angle of the Terminal
14
Remote Terminal Operation
15
Separating the Terminal from the Weighing Base
15
Terminal Mounting
15
Initial Calibration
16
Operation
17
Overview of Display, Home Screen
17
Principal Functions and Main Menu
17
Overview of Parts and Features
18
Overview of Parts and Features -Draft Shield Models
19
Overview of Parts and Features - Non-Draft Shield Models
20
Overview of Parts and Features - EX12001, EX24001 and EX35001
21
Overview of Parts and Features - Terminal
22
Functions and Their Icons
23
Standby
23
Printing Data
23
Zero Operation
23
Touchless Sensor Status
23
Autocal
23
Menu
23
More
23
Level Assist
23
Graduations
24
Routine Test
24
Applications
24
Taring a Container
24
Weighing Units
24
Ionizer (Only for EX225D/AD and EX225/AD)
24
Preset Tare
24
Calibration Test
24
Calculator
24
Stopwatch
25
Logout
25
Ionizer (EX225D/AD and EX225/AD Only) and Glass Shelf
25
Application
26
Weighing
27
Edit Settings
27
Application Setup
29
Save to USB
30
Auto Save to USB
30
Statistics for Weighing
30
Parts Counting
32
Standard Parts Counting (Default)
32
Application Setup
35
Parts Counting - Check
36
Parts Counting - Fill
37
Statistics for Parts Counting
38
Percent Weighing
40
Edit Settings
40
Application Setup
42
Check Weighing
43
Standard Check Weighing (Default)
43
Edit Settings
43
Application Setup
44
Check Weighing - Nominal/Weight Tolerance Mode
45
Check Weighing - Nominal/Percent Tolerance Mode
46
Display Settings
47
Statistics for Check Weighing
48
Dynamic/Animal Weighing
49
Edit Settings
50
Application Setup
50
Dynamic Weighing - Semi-Auto
51
Dynamic Weighing - Automatic
52
Statistics for Dynamic Weighing
53
Filling
54
Edit Settings
54
Application Setup
55
Statistics for Filling
56
Totalization
58
Totalization - Manual (Default)
58
Application Setup
59
Totalization - Automatic
60
Formulation
61
Free Formulation (Default)
61
Application Setup
62
Recipe Formulation
63
Differential Weighing
66
Item Settings
66
Application Setup
68
Differential Weighing with Auto-Process on
69
Density Determination
70
Measuring the Density of a Solid Using Water (Default)
70
Application Setup
72
Measuring the Density of a Buoyant Material Using Water
73
Measuring the Density of a Solid Using an Auxiliary Liquid
73
Measuring the Density of a Liquid Using a Calibrated Sinker (Not Supplied)
74
Measuring the Density of Porous Material Using Oil
76
Peak Hold
78
Peak Hold - Semi-Automatic (Default)
78
Application Setup
79
Peak Hold - Manual
80
Peak Hold - Automatic
81
Ingredient Costing (Not Available in Semi-Micro Models)
82
Item Settings
82
Application Setup
85
Pipette Adjustment (Not Available in EX12001, EX24001, EX35001)
86
Pipette Adjustment - Manual (Default)
86
Begin Pipette Adjustment Process
88
Application Setup
89
Statistical Quality Control (SQC)
90
Edit Settings
90
Begin the SQC Process
91
Application Setup
92
Fill Weight Variation
94
Edit Settings
94
Begin the Fill Weight Variation Process
96
Application Setup
97
Statistics
97
Library
98
Creating a Library Record
98
Retrieving a Library Record
99
Deleting a Stored Library Record
99
Additional Features
99
Weigh below
99
Menu Settings
100
Menu Navigation
100
Changing Settings
100
Main Menu
100
Calibration
101
Calibration Sub-Menu
101
Internal Calibration (Autocal™)
101
Automatic Calibration
101
Auto TM Interval (Hours)
102
Autocal™ Adjustment
102
Span Calibration
102
User Calibration
103
Calibration Test
103
User Management
104
User Settings
106
User Settings Sub-Menu
106
Change Password
106
Language
106
Volume
106
Display Settings
106
Functions Configuration
107
Touchless Sensor Setup
107
Draft Shield Light
107
Ionizer (Seconds)
107
Balance Setup
108
Balance Set-Up Sub-Menu
108
Stable Range
108
Filter Level
108
Auto Zero Tracking
108
Audible Signal
108
Auto Tare
109
Gross Indicator
109
Legal for Trade
109
Graduations
109
Date & Time
110
Applications
111
Turning an Application ON/OFF
111
Weighing Units
111
Units Sub-Menu
111
Turning a Unit ON/OFF
112
Custom Units
112
GLP and GMP Data
113
GLP Data Sub-Menu
113
Header
113
Balance Name
113
Project Name
113
Communication
114
Communication Sub-Menu
114
Baud Rate
114
Transmission
114
Handshake
115
Alternate Command
115
Print Output
115
Auto Print
115
Print Calibration Data
116
Print Content
116
Print Layout
119
Data Transfer Function
119
Library
120
Diagnostics
120
Routine Test
120
Level Bubble Light (Not Available in EX12001, EX24001, EX35001)
121
Draft Shield Light (Analytical Models)
121
Sensors
121
Automatic Draftshield Door
121
Data Maintenance
121
Service Mode
121
Factory Reset
122
Factory Reset Sub-Menu
122
Reset Calibration
122
Reset User Settings
122
Reset Balance Setup
122
Reset Application Modes
122
Reset Weighing Units
122
Reset GLP and GMP Data
122
Reset Communication
122
Reset All (Global Reset)
122
Information
123
Using Information
123
Legal for Trade
124
Settings
124
Verification
124
Sealing
124
Printing
125
Connecting, Configuring and Testing the Printer/Computer Interface
125
Printout Examples
126
Output Format
136
Maintenance
137
Calibration
137
Cleaning
137
Troubleshooting
137
Service Information
137
OHAUS Explorer EX42022 Instruction Manual (164 pages)
Brand:
OHAUS
| Category:
Scales
| Size: 15 MB
Table of Contents
Table of Contents
3
Introduction
7
Description
7
Features
7
Safety Precautions
8
Installation
9
Unpacking
9
Terminal Setup
10
Installing the Wind Ring, Weighing Platform on Semi-Micro Models
10
Installing the Wind Ring, Weighing Platform on Models EX124
10
Installing the Glass Shelf (on Semi-Micro Models)
12
Installing the Weighing Pan & Wind Shield - Non-Draft Shield Models
12
Selecting the Location
13
Leveling the Equipment
13
Connecting Power
13
Models with AC Adapter
13
Models with AC Power Cord
14
Power on Button on EX12001, EX24001 and EX35001
14
Connecting the Interface
14
Adjusting the View Angle of the Terminal
14
Remote Terminal Operation
15
Separating the Terminal from the Weighing Base
15
Terminal Mounting
15
Initial Calibration
16
Operation
17
Overview of Display, Home Screen
17
Principal Functions and Main Menu
17
Overview of Parts and Features
18
Overview of Parts and Features -Draft Shield Models
19
Overview of Parts and Features - Non-Draft Shield Models
20
Overview of Parts and Features - EX12001, EX24001 and EX35001
21
Overview of Parts and Features - Terminal
22
Functions and Their Icons
23
Standby
23
Printing Data
23
Zero Operation
23
Touchless Sensor Status
23
Autocal
23
Menu
23
More
23
Level Assist
23
Graduations
24
Routine Test
24
Applications
24
Taring a Container
24
Weighing Units
24
Ionizer (Only for EX225D/AD and EX225/AD)
24
Preset Tare
24
Calibration Test
24
Calculator
24
Stopwatch
25
Logout
25
Ionizer (EX225D/AD and EX225/AD Only) and Glass Shelf
25
Application
26
Weighing
27
Edit Settings
27
Application Setup
29
Save to USB
30
Auto Save to USB
30
Statistics for Weighing
30
Parts Counting
32
Standard Parts Counting (Default)
32
Application Setup
35
Parts Counting - Check
36
Parts Counting - Fill
37
Statistics for Parts Counting
38
Percent Weighing
40
Edit Settings
40
Application Setup
42
Check Weighing
43
Standard Check Weighing (Default)
43
Edit Settings
43
Application Setup
44
Check Weighing - Nominal/Weight Tolerance Mode
45
Check Weighing - Nominal/Percent Tolerance Mode
46
Display Settings
47
Statistics for Check Weighing
48
Dynamic/Animal Weighing
49
Edit Settings
50
Application Setup
50
Dynamic Weighing - Semi-Auto
51
Dynamic Weighing - Automatic
52
Statistics for Dynamic Weighing
53
Filling
54
Edit Settings
54
Application Setup
55
Statistics for Filling
56
Totalization
58
Totalization - Manual (Default)
58
Application Setup
59
Totalization - Automatic
60
Formulation
61
Free Formulation (Default)
61
Application Setup
62
Recipe Formulation
63
Differential Weighing
66
Item Settings
66
Application Setup
68
Differential Weighing with Auto-Process on
69
Density Determination
70
Measuring the Density of a Solid Using Water (Default)
70
Application Setup
72
Measuring the Density of a Buoyant Material Using Water
73
Measuring the Density of a Solid Using an Auxiliary Liquid
73
Measuring the Density of a Liquid Using a Calibrated Sinker (Not Supplied)
74
Measuring the Density of Porous Material Using Oil
76
Peak Hold
78
Peak Hold - Semi-Automatic (Default)
78
Application Setup
79
Peak Hold - Manual
80
Peak Hold - Automatic
81
Ingredient Costing (Not Available in Semi-Micro Models)
82
Item Settings
82
Application Setup
85
Pipette Adjustment (Not Available in EX12001, EX24001, EX35001)
86
Pipette Adjustment - Manual (Default)
86
Begin Pipette Adjustment Process
88
Application Setup
89
Statistical Quality Control (SQC)
90
Edit Settings
90
Begin the SQC Process
91
Application Setup
92
Fill Weight Variation
94
Edit Settings
94
Begin the Fill Weight Variation Process
96
Application Setup
97
Statistics
97
Library
98
Creating a Library Record
98
Retrieving a Library Record
99
Deleting a Stored Library Record
99
Additional Features
99
Weigh below
99
Menu Settings
100
Menu Navigation
100
Changing Settings
100
Main Menu
100
Calibration
101
Calibration Sub-Menu
101
Internal Calibration (Autocal™)
101
Automatic Calibration
101
Auto TM Interval (Hours)
102
Autocal™ Adjustment
102
Span Calibration
102
User Calibration
103
Calibration Test
103
User Management
104
User Settings
106
User Settings Sub-Menu
106
Change Password
106
Language
106
Volume
106
Display Settings
106
Functions Configuration
107
Touchless Sensor Setup
107
Draft Shield Light
107
Ionizer (Seconds)
107
Balance Setup
108
Balance Set-Up Sub-Menu
108
Stable Range
108
Filter Level
108
Auto Zero Tracking
108
Audible Signal
108
Auto Tare
109
Gross Indicator
109
Legal for Trade
109
Graduations
109
Date & Time
110
Applications
111
Turning an Application ON/OFF
111
Weighing Units
111
Units Sub-Menu
111
Turning a Unit ON/OFF
112
Custom Units
112
GLP and GMP Data
113
GLP Data Sub-Menu
113
Header
113
Balance Name
113
Project Name
113
Communication
114
Communication Sub-Menu
114
Baud Rate
114
Transmission
114
Handshake
115
Alternate Command
115
Print Output
115
Auto Print
115
Print Calibration Data
116
Print Content
116
Print Layout
119
Data Transfer Function
119
Library
120
Diagnostics
120
Routine Test
120
Level Bubble Light (Not Available in EX12001, EX24001, EX35001)
121
Draft Shield Light (Analytical Models)
121
Sensors
121
Automatic Draftshield Door
121
Data Maintenance
121
Service Mode
121
Factory Reset
122
Factory Reset Sub-Menu
122
Reset Calibration
122
Reset User Settings
122
Reset Balance Setup
122
Reset Application Modes
122
Reset Weighing Units
122
Reset GLP and GMP Data
122
Reset Communication
122
Reset All (Global Reset)
122
Information
123
Using Information
123
Legal for Trade
124
Settings
124
Verification
124
Sealing
124
Printing
125
Connecting, Configuring and Testing the Printer/Computer Interface
125
Printout Examples
126
Output Format
136
Maintenance
137
Calibration
137
Cleaning
137
Troubleshooting
137
Service Information
137
Advertisement
OHAUS Explorer EX42022 Instruction Manual (152 pages)
Brand:
OHAUS
| Category:
Scales
| Size: 13 MB
Table of Contents
Table of Contents
3
Introduction
7
Description
7
Features
7
Safety Precautions
7
Installation
8
Unpacking
8
Terminal Setup
9
Installing the Wind Ring, Weighing Platform on Models EX124
9
Installing the Weighing Pan & Wind Shield - Non-Draft Shield Models
11
Selecting the Location
11
Leveling the Equipment
11
Connecting Power
12
Models with AC Adapter
12
Models with AC Power Cord
12
Power on Button on EX12001, EX24001 and EX35001
12
Connecting the Interface
12
Adjusting the View Angle of the Terminal
13
Remote Terminal Operation
13
Separating the Terminal from the Weighing Base
13
Terminal Mounting
14
Initial Calibration
14
Operation
15
Overview of Display, Home Screen
15
Principal Functions and Main Menu
15
Overview of Parts and Features -Draft Shield Models
16
Overview of Parts and Features - Non-Draft Shield Models
17
Overview of Parts and Features - Terminal
19
Functions and Their Icons
20
Standby
20
Printing Data
20
Zero Operation
20
Touchless Sensor Status
20
Autocal
20
Menu
20
More
20
Level Assist
20
Applications
20
Weighing Units
21
Preset Tare
21
Calibration Test
21
Calculator
21
Stopwatch
21
Logout
21
Applications
22
Weighing
23
Edit Settings
23
Application Setup
24
Save to USB
24
Auto Save to USB
25
Statistics for Weighing
25
Parts Counting
26
Standard Parts Counting (Default)
26
Application Setup
30
Parts Counting - Check
31
Parts Counting - Fill
32
Statistics for Parts Counting
33
Percent Weighing
35
Edit Settings
35
Check Weighing
39
Standard Check Weighing (Default)
39
Edit Settings
39
Application Setup
40
Check Weighing - Nominal/Weight Tolerance Mode
41
Check Weighing - Nominal/Percent Tolerance Mode
42
Display Settings
43
Statistics for Check Weighing
44
Dynamic/Animal Weighing
45
Edit Settings
46
Application Setup
46
Dynamic Weighing - Semi-Auto
47
Dynamic Weighing - Automatic
48
Statistics for Dynamic Weighing
49
Filling
50
Edit Settings
50
Application Setup
51
Statistics for Filling
52
Totalization
54
Totalization - Manual (Default)
54
Application Setup
55
Totalization - Automatic
56
Formulation
57
Free Formulation (Default)
57
Application Setup
58
Recipe Formulation
59
Differential Weighing
62
Item Settings
62
Application Setup
64
Differential Weighing with Auto-Process on
65
Density Determination
66
Measuring the Density of a Solid Using Water (Default)
66
Application Setup
68
Measuring the Density of a Buoyant Material Using Water
69
Measuring the Density of a Solid Using an Auxiliary Liquid
69
Measuring the Density of a Liquid Using a Calibrated Sinker (Not Supplied)
70
Measuring the Density of Porous Material Using Oil
72
Peak Hold
74
Peak Hold - Semi-Automatic (Default)
74
Application Setup
75
Peak Hold - Manual
76
Peak Hold - Automatic
77
Ingredient Costing
78
Item Settings
78
Application Setup
81
Pipette Adjustment (Not Available in EX12001, EX24001, EX35001)
82
Pipette Adjustment - Manual (Default)
82
Begin Pipette Adjustment Process
84
Application Setup
85
Statistical Quality Control (SQC)
86
Edit Settings
86
Begin the SQC Process
87
Application Setup
89
Statistics
90
Library
90
Creating a Library Record
90
Retrieving a Library Record
91
Deleting a Stored Library Record
91
Additional Features
92
Weigh below
92
Menu Settings
93
Menu Navigation
93
Changing Settings
93
Main Menu
94
Calibration
94
Calibration Sub-Menu
94
Internal Calibration (Autocal™)
94
Automatic Calibration
94
Autocal™ Adjustment
95
Span Calibration
95
User Calibration
96
Calibration Test
96
User Settings
97
User Settings Sub-Menu
97
Language
97
Volume
97
Display Settings
97
User Manager
97
Functions Configuration
98
Touchless Sensor Setup
98
Draft Shield Light
98
Balance Setup
99
Balance Set-Up Sub-Menu
99
Stable Range
99
Filter Level
99
Auto Zero Tracking
99
Auto Tare
100
Gross Indicator
100
Legal for Trade
100
Graduations
100
Date & Time
100
Applications
101
Turning an Application ON/OFF
101
Weighing Units
101
Units Sub-Menu
101
Turning a Unit ON/OFF
102
Custom Units
102
GLP and GMP Data
103
GLP Data Sub-Menu
103
Header
103
Balance Name
103
User Name
103
Project Name
103
Communication
104
Communication Sub-Menu
104
Baud Rate
104
Transmission
104
Handshake
105
Alternate Command
105
Print Output
105
Auto Print
106
Print Calibration Data
106
Print Content
106
Print Layout
108
Data Transfer Function
108
Library
110
I/O Settings
110
Diagnostics
110
Level Bubble Light (Not Available in EX12001, EX24001, EX35001)
110
Draft Shield Light (Analytical Models)
110
Sensors
110
When Operated, each Sensor Should Light and Make a Sound
110
Automatic Draftshield Door
110
Service Menu
110
Factory Reset
111
Factory Reset Sub-Menu
111
Reset Calibration
111
Reset User Settings
111
Reset Balance Setup
111
Reset Application Modes
111
Reset Weighing Units
111
Reset GLP and GMP Data
111
Reset Communication
111
Reset I/O Settings
111
Lockout
112
Lockout Sub-Menu
112
Lock Calibration
112
Lock User Settings
112
Lock Balance Setup
112
Lock Application Modes
112
Lock Weighing Units
112
Lock GLP and GMP Data
112
Lock Communication
113
Lock Library
113
Lock I/O Settings
113
Factory Reset
113
Securing the Menu and Key Lock Menu Settings
113
Information
114
Using Information
114
Legal for Trade
115
Settings
115
Verification
115
Sealing
115
Printing
116
Connecting, Configuring and Testing the Printer/Computer Interface
116
Printout Examples
117
Output Format
126
Maintenance
127
Calibration
127
Cleaning
127
Troubleshooting
127
Advertisement
Related Products
OHAUS EX4202
OHAUS Explorer EX4202M
OHAUS Explorer EX4202N
OHAUS Explorer EX4202/E
OHAUS Explorer EX4202N/E
OHAUS EX423
OHAUS Explorer EX423M
OHAUS Explorer EX423N
OHAUS Explorer EX4232
OHAUS Explorer EX423/E
OHAUS Categories
Scales
Measuring Instruments
Laboratory Equipment
Recording Equipment
Touch Panel
More OHAUS Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL