Sign In
Upload
Manuals
Brands
NSC Sicherheitstechnik Manuals
Control Panel
Solution F2
NSC Sicherheitstechnik Solution F2 Manuals
Manuals and User Guides for NSC Sicherheitstechnik Solution F2. We have
1
NSC Sicherheitstechnik Solution F2 manual available for free PDF download: Operating And Installation Manual
NSC Sicherheitstechnik Solution F2 Operating And Installation Manual (49 pages)
Fire Control Panels
Brand:
NSC Sicherheitstechnik
| Category:
Control Panel
| Size: 0 MB
Table of Contents
Table of Contents
3
1 Description of Control Panel
5
LED Indications
5
LC Module Indications
6
Description of the Push Buttons
7
Configuration
7
2 Menus for the End User
9
Description
9
General Main Menu for End User
9
Main Menu „Switch on / Switch off
9
Switching On/Off: Zones and Single Detectors
10
Switching On/Off: Addressable Detectors
10
Switching On/Off: OC-Outputs
10
Switching On/Off: 6 Internal Relays
11
Switching On/Off: 4 Internal Power Outputs
11
Switching On/Off: Sounders / Strobes
11
Switching On/Off: Alarm Transmission Device (TD)
12
Switching On/Off: Alarm Transmission Delay
12
Switching On/Off: Fire Protection Outputs
12
Alarmcounter
12
Changing the End User Access Code
13
Diagnosis Menu
13
Event Memory
13
Event Memory: "Filter
13
Event Memory: "Printing
14
Detector Data
14
Table of Detectors
14
Example of Detector Data: MCP
16
Example of Detector Data: Optical Smoke Detector
17
Only for Hochiki ESP
17
Example of „Zeropoint" and „Firepoint" Display
17
Only for Apollo Discovery
18
Hardware Modules: Overview
19
Internal Modules: Details
19
Example of Details of Hochiki ESP Detector Module
19
Modem Data
19
Display of FRP/LCD Panel
20
Example of Details of a Fire Brigade Repeater Panel with Fire Brigade Control Panel
20
Example of Power Supply Voltages
20
Example of Power Output Voltages
20
Example of Input Voltages
21
Example of Displaying Software Version and Serial no
21
3 Menus for the Installer
22
Access to the Installer Menu
23
General Main Menu for Installer
23
Main Menu: Test Functions
24
Detector Test (Only for Addressable Detectors)
24
Menu "Manual Controlling
25
Manual Control: Internal OC Outputs
25
Manual Control: 6 Internal Relays
25
Manual Control: 4 Monitored Power Outputs
26
Manual Control: Output Modules (Loop)
26
Menu „Simulation
26
Menu „Revision
27
Settings 1 of FCP
27
To Set Date and Time
27
Maintenance
28
System Settings
28
Scanning RS485 Devices
29
Scan Detectors
29
Delete Configuration
30
Delete Texts
30
Delete Events
30
Selecting the Panel Language
30
Einstellungen 2 der BMZ
30
Changing the Installer Access Code
31
Configuring the Interfaces
31
Interface Protocols
31
Interface Baudrates
31
Modem Functions
32
Power Outputs: Thresholds
32
Loop Parameters
32
Options
33
ESPA 4.4.4 Settings
33
Modbus Einstellungen
33
4 Firmware Update
34
For the Flash Update of the Solution F2 Firmware You Need the Following Items
34
Preparation
34
Start of Bootloader & Flash Update Routine
34
Execute Flash Update
35
Errors and Possible Reasons
36
5 Mounting Instruction
38
6 Commissioning of Solution F2
39
General
39
Checking the Documentation
39
Checking the System Components
39
Checking the Wiring System
39
Measure Cable Resistance of Loop Wiring (Without Voltage)
40
Measurement of the End of Line Resistors of the Monitored Power Outputs (Without Voltage)
40
Measurement of the End of Line Resistors of the Monitored Inputs (Without Voltage)
40
Checking the End of Line Resistor on the RS485 Bus
41
Commissioning of the Power Supply
41
Scanning of Internal an External Components
41
Detector Modules
41
Serial Devices
42
Addressable Detectors/Modules
42
Checking of Earth Fault
43
Measurement of Loop Voltage and Current
43
Configure Power Outputs
43
Configuration of the Fire Control System
44
Functional Tests
45
7 Technical Specifications
46
8 CE Marking
47
Advertisement
Advertisement
Related Products
NSC Sicherheitstechnik Solution F1
NSC Sicherheitstechnik Categories
Speakers
Control Panel
Emergency Phone
More NSC Sicherheitstechnik Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL