Sign In
Upload
Manuals
Brands
MSA Manuals
Control Unit
SMC 5100-02-IT
MSA SMC 5100-02-IT Manuals
Manuals and User Guides for MSA SMC 5100-02-IT. We have
1
MSA SMC 5100-02-IT manual available for free PDF download: Operating Manual
MSA SMC 5100-02-IT Operating Manual (52 pages)
Gas Sensor Module
Brand:
MSA
| Category:
Control Unit
| Size: 2 MB
Table of Contents
Table of Contents
3
Product Description
5
General
5
Product Configuration
6
Theory of Operation
6
Modes of Operation
6
Classic Sentry Interface
6
Modbus Operation
6
Analog Operation
6
Remote Sensor
6
HART Connection
6
Remote Alarm Reset
6
Optional Integral Relays
7
Mechanical
7
Enclosure
7
Transmitter Electronics
8
Sensor Assembly
8
Interconnect Wiring
8
Power Requirements
8
Catalytic Bead Sensor Modules
9
Quick Start
10
Overview
10
Wiring
10
Module Installation
10
Transmitter Installation
10
Start-Up and Operation
10
Installation
11
Introduction
11
Sensor Module Locations
11
Wiring
12
Analog 4-20 Ma Operation
13
Modbus Operation Using RS-485 Connection
13
Sentry Operation Using Sentry Connection
13
General
14
Enclosure Installation
14
Transmitter and Sensor Installation
15
Module Address Switch
16
Operation
22
Introduction
22
Data Entry Keypad
22
Main Menu
23
Setup
24
Maintenance Sub-Menu
25
Calibration
27
Calibration Frequency
27
Calibration Preparation
27
Calibration Gas Delivery Methods
27
Sensor Exposure to Gas
27
Calibration Sub-Menu
28
Specifications
29
Service
31
Sensor Module Configuration
31
Enclosure Replacement
31
Transmitter Replacement
31
Sensor Replacement
32
Installation Inspection
32
Controller Installation
32
Cabling Installation
32
Sensor Module Installation
33
Moisture Traps and Rainshields
33
Standard Voltages
33
Inspection and Troubleshooting Guide
33
Module Displays "Starting" for more than 1 Hour
33
Module Does Not Display the Correct %LEL
33
Display Shows 'F' - Sensor Missing or Bad Sensor
33
Module Shows "***Calibration Required
33
Display Shows "H" or "L
33
Display Shows "M" - Not Calibrated
33
Display Shows "C" - Calibration Mode
34
Display Shows "S" - Sentry Connection
34
Diagnostic Leds
34
Error Messages
34
Parts List
35
Combustible Gas Scaling Factors
36
Limited Warranty
37
Remote Sensor Drawing
38
Modbus Memory Map
39
Hart
40
Additional Information
51
Adjusting the Gain Set of a Sensor for Extended Life and Calibration
51
Advertisement
Advertisement
Related Products
MSA SMC 5100-28-IT
MSA SMC 5100-02-IT-A1
MSA SMC 5100-02-IT-A2
MSA SMC 5100-02-IT-S1
MSA SMC 5100-02-IT-S2
MSA 5100-03-IT
MSA 5100-04-IT
MSA 5100-05-IT
MSA 5100-06-IT
MSA 5100-08-IT
MSA Categories
Safety Equipment
Respiratory Product
Security Sensors
Gas Detectors
Measuring Instruments
More MSA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL