Sign In
Upload
Manuals
Brands
Mindray Manuals
Medical Equipment
VS 8A
Mindray VS 8A Manuals
Manuals and User Guides for Mindray VS 8A. We have
2
Mindray VS 8A manuals available for free PDF download: Operator's Manual
Mindray VS 8A Operator's Manual (278 pages)
Vital Signs Monitor
Brand:
Mindray
| Category:
Medical Equipment
| Size: 3 MB
Table of Contents
Table of Contents
9
Safety
21
Safety Information
21
Warnings
21
Cautions
22
Notes
23
Equipment Symbols
24
Equipment Introduction
27
Intended Use
27
Intended Users
27
Intended Patient Population
27
Intended Medical Conditions
27
Contra-Indications
28
Applied Parts
28
Main Unit
28
Front View (VS 9 Series)
28
Front View (VS 8 Series)
29
Side View (VS 9 Series)
31
Side View (VS 8 Series)
32
Rear View (VS 9 Series)
33
Rear View (VS 8 Series)
34
Getting Started
35
Equipment Preparation Safety Information
35
Unpacking and Checking
36
Environmental Requirements
36
Setting up the Equipment
37
Installing a Battery
37
Connecting the AC Mains
38
Connecting a Barcode Reader
39
Connecting a Digital Scale
39
Turning on the Monitor
39
Start Wizard
39
Operation and Navigation
40
Using the Touchscreen
40
Using the Knob (for VS 8 Series)
41
Using the On-Screen Keyboard
41
Using the Barcode Reader
41
Screen Display
42
Main Screen
42
Menus
43
Quick Keys
44
On-Screen Symbols
44
Configuring Your Monitor
45
Setting Device Location
45
Setting the Workflow
46
Adjusting Screen Brightness
52
Adjusting the Volume
52
Changing Measurement Colors
52
Setting System Language
52
Setting the Date and Time
53
Setting Parameter Units
53
Checking Software Licenses
54
Start Working
54
Selecting a Work Mode
54
Inputting Patient Information
56
Accessing Parameter Setup Menus
56
Checking the Alarm Settings
56
Stopping a Parameter Measurement
57
Turning off the Monitor
57
Managing Patients
59
Admitting a Patient
59
Automatically Admitting a Patient
59
Manually Admitting a Patient
59
Managing Patient Information
60
Entering the Patient Management Menu
60
Editing Patient Information
60
Discharging a Patient
60
Manually Discharging a Patient
61
Auto Discharging a Patient after Monitor Power off
61
Changing Patient Management Settings
61
Setting Monitor Information
62
Setting Patient Location
62
Deleting Patient Data
62
Managing Configurations
63
Configuration Introduction
63
Changing the Department
63
Setting Default Patient Category
64
Setting Workflows
64
Transferring a Configuration
64
Exporting a Configuration
64
Importing a Configuration
64
Modifying Configuration Password
65
Restoring the Latest Configuration Automatically
65
Networked Monitoring
67
Network Introduction
67
Network Safety Information
67
Connecting the Monitor to the CMS
68
Connecting the Egateway
68
Mldap
68
Connecting the Wireless Network
69
Alarms
71
Alarm Introduction
71
Alarm Safety Information
71
Understanding the Alarms
72
Alarm Categories
72
Alarm Priorities
72
Alarm Indicators
72
Alarm Status Symbols
74
Checking Alarm List
74
Accessing On-Screen Help for Technical Alarms (Alarmsight)
74
Changing Alarm Settings
74
Setting Parameter Alarm Properties (Continuous Monitoring Mode)
74
Setting Alarm Tone Properties
75
Setting the Alarm Delay Time
76
Setting the Apnea Delay Time
76
Restoring the Default Alarm Settings
76
Setting the CMS and Egateway Disconnection Alarm
77
Setting the Switch of the Spo Desat Alarm off
77
Setting the Switch of the Apnea Alarm off
77
Pausing Alarms/Pausing Alarm Tones
77
Defining the Pause Function
77
Pausing Alarms
78
Pausing Alarm Sound
79
Resetting Alarms
80
Resetting Physiological Alarms
80
Resetting Technical Alarms
81
Setting Alarm Light Status on Alarm Reset
81
Latching Alarms
81
Nurse Call
82
Testing Alarms
82
Actions When an Alarm Occurs
82
Monitoring Pulse Oxygen Saturation (Spo )
83
Spo Introduction
83
Spo Safety Information
84
Spo Measurement Limitations
85
Spo Display
87
Preparing for Spo Monitoring
87
Changing the Spo Settings
88
Changing the Spo Alarm Settings
88
Nellcor Sat-Seconds Alarm Management
89
Setting the Nellcor Spo Sat-Seconds
90
Setting Spo Sensitivity (for Masimo Spo )
91
Enabling Fastsat (for Masimo Spo )
91
Displaying SIQ (for Masimo Spo )
92
Changing Averaging Time (for Masimo Spo )
92
Changing the Sensitivity (for Mindray Spo )
93
Showing/Hiding PI
93
Monitoring Spo and NIBP Simultaneously
93
Changing the Sweep Speed of the Pleth Wave
94
Setting the Alarm Priority for Spo2 Sensor off Alarm
94
Setting the Spo Tone Mode
94
Spo Troubleshooting
94
Nellcor Information
95
Masimo Information
96
Monitoring PR
99
PR Introduction
99
PR Display
99
Changing the PR Settings
99
Changing the PR Alarm Settings
99
Changing the Pulse Volume
100
Enabling Irregular PR
100
Measuring Temperature (Temp)
101
Temp Introduction
101
Temp Display
101
Monitoring Temp with Smartemp™ Module
102
Measuring Temp
103
Disinfecting Temperature Probe
105
Monitoring Temp with Genius™ 3 Tethered Tympanic Thermometer
106
Safety Information
106
Thermometer Buttons
106
Equivalence Mode Temperature
107
Taking a Temperature
107
Troubleshooting
108
Cleaning and Disinfecting the Tympanic Thermometer
108
Monitoring Temp with Exergen Temporalscanner™ Thermometer
108
Safety Information
109
Taking a Temperature with the Temporalscanner
109
Understanding the Temporalscanner™ Thermometer LED Display
111
Fahrenheit or Celsius Conversion
111
Replacing the Battery
112
Troubleshooting
112
Cleaning the Temporalscanner™ Thermometer
113
Monitoring Temp with Hetaida Thermometer
113
Overview of Hetaida Thermometer
113
Taking a Temperature with Hetaida Thermometer
114
Manually Inputting Temp
114
Measuring Noninvasive Blood Pressure (NIBP)
115
NIBP Introduction
115
NIBP Safety Information
116
NIBP Measurement Limitations
117
Measurement Modes
117
NIBP Display
117
Preparing for NIBP Measurement
119
Preparing the Patient for NIBP Measurement
119
Placing the NIBP Cuff
120
Performing Measurement
121
Performing Manual Measurement
121
Performing Auto Measurement
121
Performing STAT Measurement
122
Performing Sequence Measurement
122
Changing NIBP Settings
123
Setting the NIBP Alarm Properties
123
Setting the NIBP Interval
123
Enabling the NIBP End Tone
123
Setting NIBP Sequence
123
Setting the NIBP Display Format
124
Setting the NIBP Alarm Limits Display Switch
124
Selecting NIBP Measurement Algorithm
124
Setting Measurement Times
125
Correcting the NIBP Measurements
125
BP Averaging
125
Enabling BP Averaging
125
BP Averaging Display
126
Performing BP Averaging
126
Changing BP Averaging Settings
127
11.10 Orthostatic BP Measurement
128
11.10.1 Enabling Orthostatic BP Measurement
128
11.10.2 Orthostatic BP Measurement Display
128
11.10.3 Performing Orthostatic BP Measurement
129
11.10.4 Changing Orthostatic BP Measurement Settings
129
11.11 Assisting Venous Puncture
131
11.12 NIBP Maintenance
131
11.12.1 NIBP Leakage Test
131
11.12.2 NIBP Accuracy Test
132
11.13 NIBP Troubleshooting
132
Monitoring CO
133
Overview
133
Safety
133
Measurement Limitations
134
CO Display
134
Measuring CO
135
Automatic CO Module Zeroing
136
Changing CO 2 Settings
136
Changing CO Alarm Settings
136
Setting the CO Waveform
137
Entering the Standby Mode
137
Setting the Auto Standby
137
Setting Humidity Compensation
137
Setting Gas Compensation
138
Automatic Barometric Pressure
138
Calibrating the CO Module
138
Monitoring Respiration
139
Resp Safety Information
139
RR Display
139
Measurement Limitations of Spo2-Sourced RR
140
Manually Inputting RR Value
140
Changing the RR Settings
140
Enabling Spo Source for RR Measurement
140
Enabling RR Alarms
140
Setting RR Alarms
141
Setting the Apnea Alarm Delay
141
Setting Timer Interval
141
Manual Parameters
143
Manual Input Parameters
143
The Manual Input Display
143
Inputting/Editing Parameter Information
144
Changing Manual Input Settings
145
Changing the Display of Manual Parameters
145
Adding a New Parameter
145
Clinical Assistive Applications (CAA)
147
Early Warning Score (EWS)
147
The EWS Display
148
Accessing the EWS Screen
149
EWS Scoring in Spot Check Mode
150
EWS Scoring in Continuous Monitoring Mode
150
EWS Alarm
151
Changing EWS Settings
152
Viewing History Scores
153
Glasgow Coma Scale (GCS)
154
GCS Display
155
Accessing the GCS Menu
156
Performing GCS Scoring
156
Setting Threshold for each Consciousness Level
157
Reviewing GCS Data
157
Pain Score
157
The Pain Score Display
158
Performing Pain Score
158
Adding a Custom Pain Scale
158
Adding a Pain Description
159
Targeted Goal
159
Entering the Targeted Goal Screen
159
The Display of the Targeted Goal Screen
160
Operating the Targeted Goal Screen
160
Recording
163
Recorder
163
Starting Recordings
163
Stopping Recordings
164
Stopping Recordings Manually
164
Stopping Recordings Automatically
164
Recording Related Flags
164
Setting the Recorder
164
Loading Paper
165
Removing Paper Jam
165
Review
167
Review Overview
167
Review Page
167
Accessing the Review Page
167
17.2.2 Example Review Page
167
Reviewing the Tabular Trends
168
Reviewing Scores
168
Reviewing the Graphics Trends
169
Reviewing Events
169
User Maintenance Settings
171
Accessing the Maintenance Menu
171
The Device Location Settings
171
The Patient Management Settings
172
The Patient Field Tab
172
The ADT Query Tab
173
The Discharge Tab
173
The Location Tab
173
The Authorization Setup Tab
173
The Clinician Login Tab
173
The Authorization Setup Tab
174
The Save&Send Tab
175
The Alarm Tab
176
The Audio Tab
176
The Pause/Reset Tab
177
The Latching Tab
179
The Nurse Call Tab
179
The Other Tab
180
The Standby Settings
181
The CAA Settings
181
The EWS Tab
181
The GCS Tab
182
The Module Settings
182
The NIBP Tab
182
The CO2 Tab
183
The Temp Tab
184
The Manual Input Tab
184
The Pain Score Tab
184
The Other Tab
184
18.10 the Unit Settings
185
18.11 the Time Settings
185
18.11.1 the Time Synchronization Tab
185
18.11.2 the Daylight Savings Time Tab
186
18.12 the Version Tab
186
18.13 the Battery Information Settings
186
18.14 the Scanner Settings
186
18.14.1 the Scanner Info. Tab
186
18.14.2 the JADAK Barcode Tab
187
The Identify Scanner Tab (for the Non-Mindray Custom 2D Barcode Reader)
187
The Field Tab (for the Mindray Custom 2D Barcode Reader)
188
18.15 the Record Settings
188
18.16 the Network Setup Settings
188
18.16.1 the Network Type Tab
188
18.16.2 the LAN1 IP Tab
188
18.16.3 the WLAN Tab
189
18.16.4 the WLAN IP Tab
189
18.16.5 the Transfer Setup Tab
190
18.16.6 the Device Discover Tab
191
18.16.7 the Qos Tab
192
18.16.8 the MLDAP Tab
192
18.16.9 the Vitalslink Tab
192
18.17 the Bluetooth Tab
193
18.18 the Other Tab
194
Battery
195
Overview
195
Battery Safety Information
195
Battery Indications
196
Battery LED
196
Battery Symbols
196
Battery-Related Alarms
197
Replacing the Battery (for VS 9 Series)
197
Replacing the Battery (for VS 8 Series)
198
Connecting an External Battery
199
Charging a Battery
199
Maintaining the Battery
199
Conditioning the Battery
199
Checking Battery Performance
200
Storing Batteries
200
19.10 Recycling Batteries
201
Care and Cleaning
203
Care and Cleaning Introduction
203
Care and Cleaning Safety Information
203
Cleaning and Disinfecting the Main Unit
204
Cleaning the Main Unit
204
Disinfecting the Main Unit
204
Approved Cleaning and Disinfecting Agents for Main Unit
204
Cleaning and Disinfecting the Accessories
207
Cleaning and Disinfecting Agents for the NIBP Air Hose
208
Cleaning and Disinfecting Agents for the Spo
209
Cable
209
Cleaning the Accessories
210
Disinfecting the Accessories
210
Sterilization
210
Impact of Improper Cleaning
210
Maintenance
211
Maintenance Introduction
211
Maintenance Safety Information
211
Maintenance and Testing Schedule
212
Checking Version Information
213
Testing Methods and Procedures
213
Performing Visual Inspection
214
Performing Power-On Test
214
Testing the Recorder
214
Checking the Battery
214
Disposing of the Monitor
214
Accessories
215
Spo Accessories
215
Spo Extension Cable
216
NIBP Accessories
218
NIBP Hoses
218
Reusable NIBP Cuffs
218
Disposable NIBP Cuffs
219
Temp Accessories
219
Smartemp™ Accessories
219
Genius™ 3 Tympanic Thermometer Accessories
220
Exergen Temporalscanner™ Thermometer Accessories
220
Hetaida Thermometer
221
CO Accessories
221
Others
223
A Product Specifications
225
Classifications
225
Environmental Specifications
225
Main Unit
225
Smartemp™ Temperature Module
226
Genius™ 3 Temperature Module
226
Exergen Temporalscanner Thermometer
226
Hetaida Infrared Thermometer
226
Power Supply Specifications
227
AC Power Supply Specifications
227
Battery Specifications of VS 9 Series
227
Battery Supply Specifications of VS 8 Series
228
Physical Specifications
228
Hardware Specifications
228
Display Specifications of VS 9 Series
228
Display Specifications of VS 8 Series
228
Recorder Specifications
229
Leds
229
Audio Indicator
229
Monitor Interface Specifications
229
Outputs Specifications
229
Wi-Fi Technical Specifications
230
Wi-Fi Performance Specifications
230
A.5.10 Blue Tooth Specification
231
A.5.11 Bluetooth Performance Specifications
231
Measurement Specifications
232
Spo Specifications
232
Nibp
236
Temp Specifications
238
Specifications
240
RR Specifications
241
Operating Environment
242
B EMC and Radio Regulatory Compliance
243
Emc
243
Radio Regulatory Compliance
249
C Default Settings
251
Parameters Default Settings
251
Spo2 Default Settings
251
Temp Default Settings (Smartemp)
252
NIBP Default Settings
252
Default Settings
255
EWS Default Settings
256
Routine Default Settings
257
Alarm Default Settings
257
Parameter Color Default Settings
257
Display Default Settings
258
Volume Default Settings
258
Record Setup
258
System Time Default Settings
259
D Alarm Messages
261
Physiological Alarm Messages
261
General Physiological Alarm Messages
261
Spo Physiological Alarm Messages
261
PR Physiological Alarm Messages
261
NIBP Physiological Alarm Messages
262
EWS Physiological Alarm Messages
262
Technical Alarm Messages
262
General Technical Alarm Messages
263
Spo 2 Technical Alarm Messages
263
Temp Technical Alarm Messages
265
NIBP Technical Alarm Messages
266
Technical Alarm Messages
268
EWS Technical Alarms
268
Power Supply Technical Alarm Messages
269
Technical Alarm Messages Related to Networked Monitoring
270
Advertisement
Mindray VS 8A Operator's Manual (130 pages)
Vital Signs Monitor
Brand:
Mindray
| Category:
Monitor
| Size: 2 MB
Table of Contents
Table of Contents
4
Start Working
23
Selecting a Work Mode
23
Inputting Patient Information
24
Accessing Parameter Setup Menus
24
Checking the Alarm Settings
24
Connecting the CMS
24
Warnings
24
Connecting the Egateway
25
Cautions
25
Connecting the Wireless Network
25
Stopping a Parameter Measurement
25
Managing Patients
26
Admitting a Patient
26
Automatically Admitting a Patient
26
Manually Admitting a Patient
26
Discharging a Patient
26
Manually Discharging a Patient
27
Deleting Patient Data
27
Alarm Introduction
28
Alarm Safety Information
28
Alarm Categories
28
Alarm Priorities
28
Alarm Indicators
28
Alarm Status Symbols
29
Checking Alarm List
29
Accessing On-Screen Help for Technical Alarms (Alarmsight)
29
Changing Alarm Settings
29
Setting Parameter Alarm Properties (Continuous Monitoring Mode)
29
Changing the Alarm Volume
30
Setting the Apnea Delay Time
30
Restoring the Default Alarm Settings
30
Pausing Alarms
30
Pausing Alarm Sound
31
Resetting Alarms
31
Resetting Physiological Alarms
31
Resetting Technical Alarms
31
Latching Alarms
32
Testing Alarms
32
Monitoring Pulse Oxygen Saturation (Spo )
33
Spo Introduction
33
Safety Information
33
Spo Measurement Limitations
34
Spo Display
35
Preparing for Spo Monitoring
35
Changing the Spo Settings
35
Nellcor Satseconds TM Alarm Management
36
Setting the Nellcor Spo Satseconds
36
Setting Spo 2 Sensitivity (for Masimo Spo 2 )
36
Enabling Fastsat (for Masimo Spo )
37
Performing Auto Measurement
50
Performing STAT Measurement
50
Performing Sequence Measurement
51
Changing NIBP Settings
51
Setting the NIBP Alarm Properties
51
Setting the NIBP Interval
51
Selecting NIBP Start Mode
51
Enabling the NIBP End Tone
51
Setting NIBP Sequence
51
Setting the NIBP Display Format
51
Setting the NIBP Alarm Limits Display Switch
52
Setting Measurement Times
52
Correcting the NIBP Measurements
52
BP Averaging
52
Enabling BP Averaging
52
BP Averaging Display
52
Performing BP Averaging
52
Changing BP Averaging Settings
53
Orthostatic BP Measurement
53
Enabling Orthostatic BP Measurement
53
Orthostatic BP Measurement Display
53
Performing Orthostatic BP Measurement
54
Changing Orthostatic BP Measurement Settings
54
Assisting Venous Puncture
55
NIBP Troubleshooting
55
Monitoring Respiration
56
RR Display
56
Manually Inputting RR Value
56
Setting Timer Interval
56
Manual Parameters
57
Manual Input Parameters
57
The Manual Input Display
57
Inputting/Editing Parameter Information
57
Changing the Display of Manual Parameters
58
Clinical Assistive Applications (CAA)
59
Early Warning Score (EWS)
59
The EWS Display
59
Accessing the EWS Screen
59
Setting Workflows
70
Transferring a Configuration
70
Exporting a Configuration
70
Importing a Configuration
70
Modifying Configuration Password
71
Restoring the Latest Configuration Automatically
71
Password-Protected User Settings
72
Setting the Device Location
72
Setting Monitor Information
72
Setting Monitor Location
72
Enabling the Auto Obtain Bed Number Function
72
Changing Patient Management Settings
72
Selecting Displayed Patient Information
72
Selecting Query Criteria for Searching Patients in ADT Server
72
Auto Discharging a Patient after Monitor Power off
73
Auto Deleting Patient Data after Discharging a Patient
73
Clearing All Patient Data
73
Setting Patient Location Options for the Standby Screen
73
Changing the Authorization Settings
73
Setting Clinician Login
73
Selecting Password for User Maintenance
73
Selecting Password for Changing Alarm Settings
74
Selecting Password for Viewing Discharged Patient Data
74
Changing Settings about Saving and Sending Data
74
Setting Items about Saving Data
74
Setting Items about Sending Data
75
Changing the Alarm Settings
75
Setting Alarm Tone Properties
75
Setting Alarm Pausing and Resetting Properties
76
Latching Physiological Alarms
77
Selecting Alarms to be Sent to the Nurse Call System
77
Changing Alarm Priority Settings
77
Setting the Alarm Delay Time
78
Changing the Standby Settings
78
Setting Prompt Message on Standby Screen
78
Setting Auto Standby
78
Enabling Black Standby Screen
78
Changing CAA Settings
79
Selecting the Default Scoring Tool
79
Managing the Scoring Tools
79
Setting GCS Threshold for each Consciousness Level
79
Changing Module Settings
79
Selecting NIBP Measurement Algorithm
79
Selecting Temp Module
79
Setting Temp Measurement Sites
80
Adding a New Manual Parameter
80
Managing Pain Score
80
Setting Parameter Measurement Timeout
80
Enabling Outline Font for Suspected Values
80
Setting Parameter Units
81
16.10 Setting the Time
81
Checking Battery Performance
89
Recycling Batteries
89
Care and Cleaning Introduction
90
Care and Cleaning Safety Information
90
Cleaning and Disinfecting the Equipment
90
Approved Cleaning and Disinfecting Agents
90
Cleaning the Equipment
91
Disinfecting the Equipment
91
Cleaning the Thermal Print Head
92
Cleaning and Disinfecting the Accessories
92
Approved Accessories Cleaning and Disinfecting Agents
92
Cleaning the Accessories
93
Disinfecting the Accessories
93
Maintenance
94
Maintenance Introduction
94
Maintenance Safety Information
94
Maintenance and Testing Schedule
94
Checking Version Information
95
Testing Methods and Procedures
95
Performing Visual Inspection
95
Performing Power-On Test
95
NIBP Maintenance
95
NIBP Leakage Test
95
NIBP Accuracy Test
95
Disposing of the Monitor
95
Accessories
97
Spo Accessories
97
Temp Default Settings (Smartemp)
113
NIBP Default Settings
113
EWS Default Settings
115
System Time Default Settings
116
D Alarm Messages
117
Physiological Alarm Messages
117
General Physiological Alarm Messages
117
Spo
117
PR Physiological Alarm Messages
117
NIBP Physiological Alarm Messages
117
Technical Alarm Messages
117
General Technical Alarm Messages
118
Spo Technical Alarm Messages
118
Temp Technical Alarm Messages
119
NIBP Technical Alarm Messages
119
EWS Technical Alarms
120
Power Supply Technical Alarm Messages
120
Technical Alarm Messages Related to Networked Monitoring
120
Other System Technical Alarm Messages
121
The Accuracy of Masimo Spo
122
The Accuracy of Nellcor Spo 2 Sensors
124
Units
126
Abbreviations
127
Temp
129
Advertisement
Related Products
Mindray V Series
Mindray VS 9A
Mindray VS 9C
Mindray VS 8C
Mindray VS-900c
Mindray BeneFusion VP5 Neo
Mindray V10-4B
Mindray V11-3Ws
Mindray V11-3B
Mindray V11-3BE
Mindray Categories
Medical Equipment
Diagnostic Equipment
Measuring Instruments
Monitor
Water Pump
More Mindray Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL