Sign In
Upload
Manuals
Brands
MICRO-EPSILON Manuals
Accessories
ILD 1320-10
MICRO-EPSILON ILD 1320-10 Manuals
Manuals and User Guides for MICRO-EPSILON ILD 1320-10. We have
2
MICRO-EPSILON ILD 1320-10 manuals available for free PDF download: Operating Instructions Manual, Instruction Manual
MICRO-EPSILON ILD 1320-10 Operating Instructions Manual (112 pages)
Brand:
MICRO-EPSILON
| Category:
Security Sensors
| Size: 5 MB
Table of Contents
Table of Contents
3
Safety
9
Symbols Used
9
Warnings
9
Notes on CE Marking
10
Notes on UKCA Marking
11
Intended Use
11
Proper Environment
11
Laser Safety
12
Functional Principle, Technical Data
14
Short Description
14
Auto Target Compensation (ATC)
15
Technical Data
16
Delivery
18
Unpacking, Included in Delivery
18
Storage
18
Structure of the Serial Number
18
Installation
19
Notes for Operation
19
Reflection Factor of the Target Surface
19
Error Influences
20
Light from Other Sources
20
Color Differences
20
Temperature Influences
20
Mechanical Vibration
20
Movement Blurs
20
Surface Roughness
21
Angle Influences
22
Optimizing the Measuring Accuracy
23
Mounting, Dimensions
24
Indicator Elements at Sensor
26
Electrical Connections
27
Connection Possibilities
27
Pin Assignment
29
Supply Voltage
30
Laser on
30
RS422 Connection with USB Converter IF2001/USB
31
Analog Output
31
Multifunctional Input
32
Digital Output
33
Sensor Cable
34
Operation
35
Getting Ready for Operation
35
Parameterizing Via Web Interface
36
Preconditions
36
Access Via Web Interface
37
Calibration Protocol
38
Presets, Setups, Measurement Configuration, Signal Quality
39
Measurement Presentation Via Web Browser
41
Video Signal Via Web Browser
43
Programming Via ASCII Commands
45
Timing, Measurement Value Flux
45
Set Sensor Parameter
46
Preliminary Remarks to the Adjustments
46
Overview Parameter
46
Inputs
47
Signal Processing
47
Preliminary Remark
47
Measurement Task
48
Measuring Rate
49
Triggering
50
General
50
Signal Processing - Value Output Trigger
52
Peak Selection
52
Error Handling
52
Zeroing and Mastering
53
Zeroing, Mastering with Select Key
54
Zeroing, Mastering with Hardware Input
55
Outputs
56
Overview
56
Digital Output, RS422
57
Values, Ranges
57
Characteristics Digital Output
59
Analog Output Scaling
61
Output Scaling
61
Output Scaling with Key Select
62
Output Scaling Via Hardware Input
63
Calculation of Measuring Value Using Analog Current
64
Characteristics Distance Value and Analog Output
66
Mastering and Teaching Analog Output
68
Error Output
69
Output Interface
70
System Settings
71
General
71
Unit, Language
71
Keylock
71
Load, Save
72
Import, Export
74
Access Authorization
75
Sensor Reset
76
Digital Interfaces RS422
77
Preliminary Remarks
77
Measurement Data Format
77
Conversion of the Binary Data Format
78
Cleaning
79
Software Support with Medaqlib
79
Disclaimer
80
Service, Repair
80
Decommissioning, Disposal
81
Appendix
82
A 1 Optional Accessories
82
A 2 Factory Settings
84
A 3 ASCII Communication with Sensor
85
A 3.1 General
85
A 3.2 Overview Commands
87
A 3.3 General Commands
90
A 3.3.1 Help
90
A 3.3.2 GETINFO, Sensor Information
90
A 3.3.3 LANGUAGE, Website
90
A 3.3.4 RESET, Boot Sensor
91
A 3.3.5 RESETCNT, Reset Counter
91
A 3.3.6 ECHO, Switching the Command Reply, ASCII Interface
91
A 3.3.7 PRINT, Sensor Settings
92
A 3.3.8 User Level
93
A 3.3.8.1 LOGIN, Change of the User Level
93
A 3.3.8.2 LOGOUT, Change into User Level
93
A 3.3.8.3 GETUSERLEVEL, User Level Request
93
A 3.3.8.4 STDUSER, Set Standard User
93
A 3.3.8.5 PASSWD, Change Password
93
A 3.3.9 Triggering
94
A 3.3.9.1 TRIGGER, Selection
94
A 3.3.9.2 MFILEVEL, Input Pulse Multifunctional Input
94
A 3.3.9.3 TRIGGERCOUNT, Number of Displayed Measurement Values
94
A 3.3.9.4 TRIGGERSW, Software Trigger Pulse
94
A 3.3.10 Interfaces
95
A 3.3.10.1 Baudrate, Rs422
95
A 3.3.10.2 UNIT, Web Interface
95
A 3.3.10.3 MFIFUNC, Function Selection Multifunctional Input
95
A 3.3.10.4 ERROROUT1, Activate Error Output
95
A 3.3.10.5 ERRORLEVELOUT1, Output Level Digital Output
96
A 3.3.10.6 Errorlimit
96
A 3.3.10.7 Errorhysteresis
96
A 3.3.10.8 Errorouthold
96
A 3.3.11 Handling of Setups
97
A 3.3.11.1 Import
97
A 3.3.11.2 Export
97
A 3.3.11.3 MEASSETTINGS, Load / Save Measurement Settings
97
A 3.3.11.4 BASICSETTINGS, Load / Save Device Settings
98
A 3.3.11.5 SETDEFAULT, Default Settings
98
A 3.3.12 ANALOGSCALE, Scaling the Analog Output
98
A 3.3.13 Key Function
99
A 3.3.13.1 KEYFUNC, Choose Key Function
99
A 3.3.13.2 KEYLOCK, Set Keylock
99
A 3.4 Measurement
99
A 3.4.1 MEASPEAK, Choice of the Peak in the Video Signal
99
A 3.4.2 MEASRATE, Measuring Rate
99
A 3.4.3 LASERPOW, Laser Power
99
A 3.4.4 Measurement Value Processing
100
A 3.4.4.1 MASTERMV, Mastering / Zeroing
100
A 3.5 Data Output
100
A 3.5.1 OUTPUT, Selection of Measurement Value Output
100
A 3.5.2 OUTHOLD, Error Processing
100
A 3.5.3 Selection of Measurement Values to be Output
101
A 3.5.3.1 GETOUTINFO_RS422, Request Data Selection
101
A 3.5.3.2 OUTADD_RS422, Selection of Data Additional Values
101
A 3.6 Example Command Sequence During Selection of Measurement Value
101
A 3.7 Error Messages
102
A 4 Control Menu
104
A 4.1 Tab Home
104
A 4.2 Tab Settings
104
A 4.2.1 Inputs
104
Signal Processing
105
Outputs
107
A 4.2.4 System Settings
109
Advertisement
MICRO-EPSILON ILD 1320-10 Instruction Manual (108 pages)
Brand:
MICRO-EPSILON
| Category:
Accessories
| Size: 4 MB
Table of Contents
Table of Contents
3
1 Safety
9
Symbols Used
9
Warnings
9
Notes on CE Identification
10
Proper Use
11
Proper Environment
11
2 Laser Class
12
3 Functional Principle, Technical Data
14
Short Description
14
Auto Target Compensation (ATC)
15
Technical Data
16
4 Delivery
18
Unpacking
18
Storage
18
5 Installation
19
Instructions for Installation
19
Reflection Factor of the Target Surface
19
Error Influences
19
Light from Other Sources
19
Color Differences
20
Surface Roughness
20
Temperature Influences
20
Mechanical Vibration
20
Movement Blurs
20
Angle Influences
21
Optimizing the Measuring Accuracy
21
Mounting, Dimensions
22
Indicator Elements at Sensor
24
Electrical Connections
25
Connection Possibilities
25
Pin Assignment
27
Supply Voltage
28
Laser on
28
RS422 Connection with USB Converter IF2001/USB
29
Analog Output
29
Optoncdt
29
Multifunctional Input
30
Digital Output
31
Sensor Cable
32
6 Operation
33
Getting Ready for Operation
33
Operation Via Web Interface
34
Preconditions
34
Access Via Web Interface
36
Measurement Presentation Via Web Browser
38
Video Signal Via Web Browser
40
Programming Via ASCII Commands
42
Timing, Measurement Value Flux
42
7 Set Sensor Parameter
43
Preliminary Remarks to the Adjustments
43
Overview Parameter
43
Inputs
44
Signal Processing
44
Preliminary Remark
44
Measurement Task
45
Measuring Rate
46
Triggering
47
General
47
Signal Processing - Value Output Trigger
49
Peak Selection
50
Error Handling
50
Zeroing and Mastering
51
Zeroing, Mastering with Select Key
52
Zeroing, Mastering with Hardware Input
53
Outputs
54
Overview
54
Optoncdt
54
Digital Output, RS422
55
Values, Ranges
55
Characteristics Digital Output
57
Analog Output Scaling
59
Output Scaling
59
Output Scaling with Key Select
60
Output Scaling Via Hardware Input
61
Calculation of Measuring Value Using Analog Current
62
Characteristics Distance Value and Analog Output
64
Mastering and Teaching Analog Output
66
System Settings
67
General
67
Unit, Language
67
Keylock
68
Load, Save
69
Import, Export
71
Access Authorization
72
Sensor Reset
73
8 Digital Interfaces RS422
74
Preliminary Remarks
74
Measurement Data Format
74
Conversion of the Binary Data Format
75
9 Cleaning
76
10 Software Support with Medaqlib
77
11 Warranty
78
12 Decommissioning, Disposal
78
13 Service, Repair
78
Appendix
79
A 1 Optional Accessories
79
Optoncdt
79
Factory Setting
80
A 3 ASCII Communication with Sensor
81
A 3.1 General
81
Overview Commands
83
A 3.3 General Commands
86
A 3.3.1 Help
86
A 3.3.2 GETINFO, Sensor Information
86
A 3.3.3 LANGUAGE, Website
86
A 3.3.4 RESET, Boot Sensor
87
A 3.3.5 RESETCNT, Reset Counter
87
A 3.3.6 ECHO, Switching the Command Reply, ASCII Interface
87
A 3.3.7 PRINT, Sensor Settings
88
A 3.3.8 User Level
89
A 3.3.8.1 LOGIN, Change of the User Level
89
A 3.3.8.2 LOGOUT, Change into User Level
89
A 3.3.8.3 GETUSERLEVEL, User Level Request
89
A 3.3.8.4 STDUSER, Set Standard User
89
A 3.3.8.5 PASSWD, Change Password
89
A 3.3.9 Triggering
90
A 3.3.9.1 TRIGGER, Selection
90
A 3.3.9.2 MFILEVEL, Input Pulse Multifunctional Input
90
A 3.3.9.3 TRIGGERCOUNT, Number of Displayed Measurement Values
90
A 3.3.9.4 TRIGGERSW, Software Trigger Pulse
90
A 3.3.10 Interfaces
91
A 3.3.10.1 Baudrate, Rs422
91
A 3.3.10.2 UNIT, Web Interface
91
A 3.3.10.3 MFIFUNC, Function Selection Multifunctional Input
91
A 3.3.10.4 ERROROUT1, Activate Error Output
91
A 3.3.10.5 ERRORLEVELOUT1, Output Level Digital Output
92
A 3.3.10.6 Errorlimit
92
A 3.3.10.7 Errorhysteresis
92
A 3.3.10.8 Errorouthold
92
A 3.3.11 Handling of Setups
93
A 3.3.11.1 Import
93
A 3.3.11.2 Export
93
A 3.3.11.3 MEASSETTINGS, Load / Save Measurement Settings
93
Optoncdt
93
A 3.3.11.4 BASICSETTINGS, Load / Save Device Settings
94
A 3.3.11.5 SETDEFAULT, Default Settings
94
A 3.3.12 ANALOGSCALE, Scaling the Analog Output
94
A 3.3.13 Key Function
95
A 3.3.13.1 KEYFUNC, Choose Key Function
95
A 3.3.13.2 KEYLOCK, Set Keylock
95
A 3.4 Measurement
95
A 3.4.1 MEASPEAK, Choice of the Peak in the Video Signal
95
A 3.4.2 MEASRATE, Measuring Rate
95
A 3.4.3 LASERPOW, Laser Power
95
A 3.4.4 Measurement Value Processing
96
A 3.4.4.1 MASTERMV, Mastering / Zeroing
96
A 3.5 Data Output
96
A 3.5.1 OUTPUT, Selection of Measurement Value Output
96
A 3.5.2 OUTHOLD, Error Processing
96
A 3.5.3 Selection of Measurement Values to be Output
97
A 3.5.3.1 GETOUTINFO_RS422, Request Data Selection
97
A 3.5.3.2 OUTADD_RS422, Selection of Data Additional Values
97
A 3.6 Example Command Sequence During Selection of Measurement Value
97
A 3.7 Error Messages
98
A 4 Control Menu
100
A 4.1 Tab Home
100
A 4.2 Tab Settings
100
A 4.2.1 Inputs
100
Signal Processing
101
A 4.2.2 Signal Processing
101
Outputs
103
A 4.2.3 Outputs
103
A 4.2.4 System Settings
105
Advertisement
Related Products
MICRO-EPSILON ILD 1320-25
MICRO-EPSILON ILD 1320-50
MICRO-EPSILON ILD 1320-100
MICRO-EPSILON ILD1700-20LL
MICRO-EPSILON ILD1700-50LL
MICRO-EPSILON ILD 1220-25
MICRO-EPSILON ILD 1220-200
MICRO-EPSILON ILD 1220-500
MICRO-EPSILON ILD1900-2
MICRO-EPSILON ILD1900-2LL
MICRO-EPSILON Categories
Measuring Instruments
Accessories
Industrial Equipment
Security Sensors
Controller
More MICRO-EPSILON Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL