Sign In
Upload
Manuals
Brands
McQuay Manuals
Controller
MicroTech 2000
McQuay MicroTech 2000 Manuals
Manuals and User Guides for McQuay MicroTech 2000. We have
1
McQuay MicroTech 2000 manual available for free PDF download: Installation And Maintenance Manual
McQuay MicroTech 2000 Installation And Maintenance Manual (20 pages)
Water Source Heat Pump Unit Controller
Brand:
McQuay
| Category:
Controller
| Size: 1 MB
Table of Contents
Table of Contents
2
Introduction
3
General Information
4
Component Data
4
Microprocessor
4
Yellow Status LED
4
Service Pin
4
Red Service LED
4
Temperature Sensing
4
Standard Control Features
5
Compressor Short Cycle Protection
5
Random Start
5
Delayed Reversing Valve De-Energization
5
Condensate Overflow Alarm
5
Brownout Alarm
5
High Pressure Refrigerant Alarm
5
Low Temperature Refrigerant Alarm
5
Low Pressure Refrigerant Alarm
5
Change Filter Notification (Network Units Only)
5
Configurable Relay Outputs
6
Boilerless System/Auxiliary Heat Relay (Lonworks Only)
6
Boilerless System/Auxiliary Heat Relay (Lonmark Only)
6
Motorized Valve Relay
6
Fresh Air Damper Relay
6
Timed Output Relay (Lonworks Only)
6
Interface Features
7
Microtech Network
7
Wall-Mounted Sensor
7
Remote Room Set Point Adjustment
7
Tenant Override
7
Commissioning
8
Pre-Start
8
Required Tools and Literature
8
Water Source Heat Pump Identification
8
Field Wiring Check
8
Wall Sensor Packages
8
Network Communications Units
8
Set Points
8
Start-Up
8
Procedure for WSHP
9
Description of Operation
10
Fan Operation
10
Unoccupied Operating Mode
10
Cooling Operation
10
Heating Operation
10
Occupied Operating Mode
10
Holding Mode
11
Tenant Override Mode
11
Load Shed Mode (Lonworks Only)
11
Optimal Start (Lonworks Only)
11
Faults
11
Diagnostic Service
12
Unit Identification (Wink) Command
12
Alarm Monitoring and Control
12
Clearing Faults
12
Alarm Fault Descriptions
12
High Pressure Fault
12
Low Temperature Fault
12
Low Pressure Faults
13
Condensate Overflow Fault
13
Brownout Fault
13
Change Filter Notification (Network Units Only)
13
Service Information
14
Inputs and Outputs
14
Analog Inputs
14
Digital Outputs
14
Input/Output Tables
14
Test Procedures
14
Microprocessor Problems
14
Power Supply Problems
14
Erroneous Temperature Readings
15
Digital Input Faults
15
Brownout Fault
15
WSHP Controller Replacement
15
Advertisement
Advertisement
Related Products
McQuay MicroTech III RAH
McQuay MicroTech III RDS
McQuay MicroTech III RCS
McQuay MicroTech III RDT
McQuay MicroTech III RFS
McQuay MicroTech III RPS
McQuay MicroTech III SWP
McQuay MicroTech III SWT
McQuay MicroTech MAG
McQuay MicroTech II
McQuay Categories
Air Conditioner
Chiller
Heat Pump
Air Handlers
Controller
More McQuay Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL