Sign In
Upload
Manuals
Brands
LST Manuals
Control Panel
Series BC216
LST Series BC216 Detection Control Panel Manuals
Manuals and User Guides for LST Series BC216 Detection Control Panel. We have
3
LST Series BC216 Detection Control Panel manuals available for free PDF download: User Manual, Brochure & Specs
LST Series BC216 User Manual (200 pages)
Connection of detectors
Brand:
LST
| Category:
Control Panel
| Size: 9 MB
Table of Contents
Table of Contents
3
Introduction
11
General
11
Types of Symbols
11
Important Tips
11
Conventional Technology
12
General
12
Installation of Detectors
12
Schematic Circuit Diagram of a Detector Zone
12
Conditions of Zones
12
Cable Requirements
13
Connection of Manual Call Points
14
Connection of HFM/HM
14
Connection of HFM/HM with Individual Address Module NG58-1
15
Connection of HFM/HM with Address Module NG58-1 - Sum Indication
16
Connection of Manual Call Points Series HME
17
Connection of a C31
18
Connection of the Spring-Button Call Point Sm/5/52/02/0X
19
Arrangement of Wires in Detector Base FC600/BR, FC600/BRD, FC600/BREL
20
Automatic Detectors Series FC600
20
Connection
20
Connection of Automatic Detectors
20
Connection of Detectors with Remote Indicator PA58-3 and Address Module NG58-1
21
Connection with Diode Base FC600/BRD
21
Connection of Detectors with Relay Base FC600/BREL
22
Connection of Detectors with Remote Indicator PA58-3 and Address Module NG58-1
22
Arrangement of Wires in Detector Base FC600/BR, FC600/BRD, FC600/BREL
23
Automatic Detectors Series FC650
23
Connection
24
Connection with Diode Base FC600/BRD
24
Connection of Detectors with Remote Indicator PA58-3 and Address Module NG58-1
25
Connection of Detectors with Relay Base FC600/BREL
26
Connection of Duct Detectors FI700/DDH / FI750/DDH / FI750/DDH-2
27
Intrinsically Safe Detection Circuits
28
Optical Smoke Detector SLR-E-IS
29
Automatic Detectors Series ORBIS I.S
30
Thermal Detectors 6295 and 6296 with Safety Barrier ES58-2
31
Detectors Without Energy Storage - Contact Detectors
32
Manual Call Point with Zener Barrier Z978
33
Manual Call Point with Safety Barrier ES58-2
34
Thermal Max Detector with Zener Barrier Z978
35
Thermal Max Detector with Safety Barrier ES58-2
36
Intrinsically Safe Detectors for Hazardous Areas
37
Manual Call Point Ex Dc31
37
Manual Call Points for Hazardous Areas
37
Flame Detectors for Hazardous Areas
38
Flame Detectors Series 16000
39
Connection
40
Connection of Series Fi7X0/Rf Wireless Detectors
40
Notes
40
RF Interface Fi7X0/Rf/Cwe
40
Connection FI700/RF/WE - New Version - and FI720/RF/WE
41
Connection FI700/RF/WE - Old Version
41
RF Expander Fi7X0/Rf/We
41
Connection
42
Connection of Special Detectors
42
Flame Detector Series 16000
42
Settings
42
Flame Detector Series 800/24-VST-K-N
43
Thermal Detectors 6295, 6296, 6297 and 6298
44
Notes
44
Connection
44
Thermal Max Detector SWM-1KL
45
Notes
45
Connection
45
Thermal Max Detector SWM-1KL-140
46
Notes
46
Connection
46
Thermal Detector HT-27121-275
47
Notes
47
Connection
47
Heat Detector WMX5000FS
48
Connection
48
Notes
48
Linear Detectors
49
Linear Heat Detector Unit LWM-1
49
Linear Heat Detector Unit SCU800
50
Linear Heat Detector Unit SKM-03
51
Linear Heat Detector Unit ADW511A
52
Linear Heat Detector Unit ADW535-1
53
Beam Smoke Detector FR50/100
54
Beam Smoke Detector FR2000
55
Beam Smoke Detector FR3000
56
Beam Smoke Detector FR5000
57
Old Version
57
New Version
58
Beam Smoke Detector Thefirebeam Plus
59
Smoke Aspiration Systems
60
Smoke Aspiration System Titanus PRO·SENS - TP1/A
60
Connection of One Unit
60
Smoke Aspiration System Titanus PRO·SENS - TP1/A with 2 Channels
61
Smoke Aspiration System Titanus PRO SENSE - TP-4
62
Smoke Aspiration System Titanus TOP SENSE - TT-1
63
Smoke Aspiration System Titanus Super Sens - T-SS
64
Smoke Aspiration System Vesda VLF-250 / VLF-500
65
Smoke Aspiration System ASD532
66
Smoke Aspiration System ASD535 - 1 Channel
67
Smoke Aspiration System ASD535 - 2 Channels
68
Smoke Aspiration System ASD533
69
Smoke Aspiration System FAAST 8100E
70
Smoke Aspiration System FAAST LT - Model Fl01Xx - with 2 Channels
71
Connection of Door Magnets
72
Connection of Sounders and Strobes
73
EMA1224B4R D / EMA1224B4W D (Old Version)
73
EMA1224B4R-D / EMA1224B4W-D (New Version)
73
Sounder Ema1224B4X
73
Sounder DBS1224B4W D (Old Version)
74
Sounder DBS1224B4W-D (New Version)
74
Sounder Dbs1224B4X
74
Sounder MS1R
75
Sounder ROLP
76
Sounder ROLP/SV
77
Sounder SQUASHNI
78
Sounder SQUASHNI/SV
79
Sounder SYMPHONI HO
80
Sounder ASKARI - AC/SV/R/S - AC/SV/W1/S
81
Sounder-Strobe ROLP-SOLISTA
82
Sounder CWSO-XX-XX
83
Sounder-Strobe FLASHNI-SV
84
Sounder-Strobe FLASHNI-SV with Separate Actuation
85
Sounder-Strobe CWSS-XX-XX
86
Strobe SOLEX
87
Strobe SOLISTA LX
88
Strobe Ema24Rs5X
89
Strobe CWST-XX-XX
90
Coding of Address Module NG58-1
91
ADM Technology
92
General
92
Hints for Project Planning
92
Cable Requirements
93
Unshielded Cable
93
Shielded Cable
94
Address Programming of Loop Elements
95
AUTO-Addressing of Elements
95
AUTO-Setup - Automatic Addressing of All Loop Elements
95
[Initialize New Devices] - AUTO-Addressing of New Elements
98
Manual Addressing of Elements
99
Programming Units FI700/PU and FI750/PU
99
Switching on the Programming Unit FI700/PU or FI750/PU
100
Switching off the Programming Unit FI700/PU or FI750/PU
100
Connection of Loop Elements to the Programming Unit FI700/PU or FI750/PU
100
Expert Mode
102
Reading the Address
102
Setting the Address
102
Connection of Manual Call Points
103
Manual Call Points - Series FI700/MCP
103
Programming of the Address
103
Manual Call Points - HFM / HM
103
Manual Call Points Series HME
104
Connection of Intelligent Automatic Detectors
105
Automatic Detectors Series FI700
105
Connection of Detector Bases
105
Connection of Detector Bases FI700/B, FI700/BD, FI700/BREL
105
Programming of the Address of Automatic Detectors
105
Connection of Detector Bases FI700/B, FI700/BD, FI700/BREL with PA58-3
106
Automatic Detectors Series FI750
107
Connection of Detector Bases FI750/B
107
Programming the Address of Automatic Detectors
107
Connection of Duct Detector FI700/DDH
108
FI700/DDH with Series FI700
108
Connection of Duct Detector FI750/DDH
109
FI750/DDH with Series FI750
109
Automatic Detectors and Manual Call Points with the Conventional Zone Module FI700/M1CZ
110
Intrinsically Safe Detection Circuits for Hazardous Areas
110
Optical Smoke Detector SLR-E-IS
110
Automatic Detectors Series ORBIS I.S
111
Thermal Detectors 6295 and 6296
112
Intrinsically Safe Detectors for Hazardous Areas
113
Manual Call Point Ex Dc31
113
Flame Detectors - Series 16000
115
Contact Detectors with Monitor Modules and Zener Barrier Z978
117
Detectors Without Energy Storage - Contact Detectors
117
Connection with Monitor Module FI700/M1IN
118
Connection of Wireless Detectors Series Fi7X0/Rf
119
RF Interface Fi7X0/Rf/W2W
119
Notes
119
Connection
119
RF Expander Fi7X0/Rf/We
120
Connection FI700/RF/WE - Old Version
120
Connection FI700/RF/WE - New Version - and FI720/RF/WE
120
Connection of Conventional Detectors with a Conventional Zone Module FI700/M1CZ
121
Address Setting
121
Power Supply
121
Supply from the Fire Detection Control Panel or by an External Power Supply
122
Power Supply from the Loop
123
Manual Call Points Series C31
124
Detectors Series FC600 / FC650
125
Connection of Detectors Series FC600 / FC650 and External Power Supply of the Module
125
Flame Detector Series 16000
126
Note
126
Connection
126
Flame Detector 800/24-VST-K-N
127
Linear Heat Detector Unit Alarmline LWM-1
128
Linear Heat Detector Unit SKM-03
129
Linear Heat Detector Unit SCU800
130
Linear Heat Detector Unit ADW511A
131
Linear Heat Detector Unit ADW535
132
Beam Smoke Detector FR50/100
133
Beam Smoke Detector FR2000
134
Beam Smoke Detector FR3000
135
Beam Smoke Detector FR5000
136
Old Version
136
Beam Smoke Detector FR5000 (Issue-11)
137
Beam Smoke Detector Thefirebeam Plus
138
Beam Smoke Detectors 6500R and 6500RS
139
Smoke Aspiration System Titanus PRO·SENS - TP-1/A with One Detector Module
140
Smoke Aspiration System Titanus PRO·SENS - TP1/A with 2 Detector Modules
141
Smoke Aspiration System Titanus PRO SENS - TP-4 with 2 Detector Modules
142
Smoke Aspiration System Titanus TOP SENS - TT-1 with 2 Detector Modules
143
Smoke Aspiration System Titanus Super Sens - T-SS
144
Vlf-500
145
Smoke Aspiration System ASD532
146
Smoke Aspiration System ASD535 with One Channel
147
Smoke Aspiration System ASD535 with Two Channels
148
Smoke Aspiration System ASD533
149
Smoke Aspiration System FAAST LT - Model FL0122
150
Smoke Aspiration System FAAST 8100E
151
Thermal Detectors 6295, 6296, 6297 and 6298
152
Notes
152
Connection
152
Thermal Max Detector SWM-1KL
153
Thermal Max Detector SWM-1KL-140
154
Thermal Max Detector HT-27121-275
155
Address Setting
156
Connection of Contact Detectors with Monitor Modules
156
Connection of the Modules FI700/M1IN, FI700/MM1IN, FI700/MDR1IN
156
Function of the LED
156
Monitor Modules FI700/M1IN, FI700/MM1IN or FI700/MDR1IN
156
Connection
157
Monitor Module FI700/MMC1IN
157
Address Setting
158
Control Modules
158
Control Modules with Supervision
158
Function of the LED
158
Connection of Sirens with FI700/M1OUT, FI700/MM1OUT, FI700/MDR1OUT
159
Connection of Sirens with FI700/MMC1OUT
159
Connection of Door Magnets with FI700/M1OUT, FI700/MM1OUT, FI700/MDR1OUT
160
Connection of Door Magnets with FI700/MMC1OUT
160
Control Modules with Relay Output
161
Address Setting
161
Connection of Control Modules FI700/M1REL, FI700/MM1REL, FI700/MDR1REL
161
Function of the LED
161
Connection of Control Module FI700/MMC1REL
162
Combi Modules
163
Combi Modules with One (1) Supervised Input and One (1) Supervised Output
163
Address Setting
163
Function of the Leds
163
Connection of Combi Modules FI700/M1IN1OUT, FI700/MM1IN1OUT, FI700/MDR1IN1OUT
164
Combi Module with One (1) Supervised Input and One (1) Relay Output
165
Address Setting
165
Function of the Leds
165
Connection of Combi Modules FI700/M1IN1REL, FI700/MM1IN1REL, FI700/MDR1IN1REL
165
Connection of Combi Module FI700/MMC1IN1REL
166
Combi Module with Four (4) Supervised Inputs and Four (4) Relay Outputs
167
Address Setting
167
Connection of Combi Module FI700/M4IN4REL
167
Function of the Leds
167
Address Setting
168
Combi Module with Four (4) Supervised Inputs, Two (2) Supervised Outputs and Two (2) Relay Outputs
168
Connection of Combi Module FI700/M4IN2OUT2REL
168
Function of the Leds
168
Address Setting
169
Combi Module with Six (6) Supervised Inputs and Two (2) Relay Outputs
169
Connection of Combi Module FI700/M6IN2REL
169
Function of the Leds
169
Address Setting
170
Loop Sounders and Strobes
170
Notes
170
Connection
171
Sounder FI700/WM/MT/SOUR - FI700/WM/MT/SOUW
171
Sounder FI700/WM/SOUR - FI700/WM66/SOUR
171
Tone Setting
171
Connection
172
Tone Setting
172
Sounder FI700/FB/MT/SOUW
173
Connection
173
Tone Setting
173
Sounder-Strobe FI700/FBRI/MT/SOUW/STRR
174
Connection
174
Tone Setting
174
Sounder-Strobe FI700/WM/SOUR/STRR - FI700/WM66/SOUR/STRR
175
Connection
175
Tone Setting
175
Sounder(-Strobe) Cws/Soux / Cws/Soux/Strc with Module FI700/M/SST / FI750/M/SST
176
Connection
176
Tone Setting - Cws/Soux(/STRC) with Fi7X0/M/Sst
176
Sound Level - Cws/Soux(/STRC) with Fi7X0/M/Sst
177
Strobe FI700/WM/STRRR
178
Connection
178
Flash Frequency and Brightness
178
Sounder(-Strobe) FI700/WB/MT/SOUW - FI700/WB/MT/SOUW/STRC
179
Connection
179
Tone Setting
179
Sounder(-Strobe) FI700/WBRI/MT/SOUW - FI700/WBRI/MT/SSTWC
180
Connection
180
Tone Setting
180
Sound Level - FI700/WBRI/MT/SOUW and FI700/WBRI/MT/SSTWC
180
Sounder(-Strobe) FI750/WB/MT/SOUW - FI750/WB/MT/SOUW/STRC
181
Connection
181
Tone Setting
181
Sounder-Strobe FI750/WBRI/MT/SOUW - FI750/WBRI/MT/SSTWC
182
Connection
182
Tone Setting
182
Sound Level - FI750/WBRI/MT/SOUW
182
Sound Level - FI750/WBRI/MT/SSTWC
183
Connection
184
Tone Setting
185
Sound Level
185
Flash Energy
185
Sounder-Strobe FI750/WBRIS/SOUW - FI750/WBRIS/SSTWCR - FI750/WBRIS/SSTWCW
186
Connection
186
Tone Setting
186
Sound Level
187
Flash Energy
187
Remote Indicator
188
Address Setting
188
Example for the Wiring of Detector Circuits
189
System Cabling ADM Loop
189
Programming of Detectors, Modules and Signalling Devices
190
Parameterising Detectors on the BC216
190
Fi700/Fbri/Mt/Souw
191
Fi700/Pa
191
Parameterising Signalling Devices on the BC216
191
Parameterising Remote Indicators on the BC216
191
Parameterising Modules on the BC216
192
Parameterising Wireless Elements on the BC216
193
Settings of the Wireless Detectors that Are Made with the Parameterisation Software Wirelex
194
Analogue Values - Condition of Detectors/Modules
195
Function of the Leds
195
Automatic Detectors
195
Modules
195
Manual Call Points Series HFM/HME
195
Standard Detectors
196
Optical Smoke Detectors
196
Thermal Detector
196
Optical-Thermal Detectors
196
Manual Call Points
196
Remote Indicator
197
Wireless Elements
198
RF Interface - Fi7X0/Rf/W2W
198
Wireless Manual Call Point - FI700/RF/MCP
198
Automatic Wireless Detectors - Fi7X0/Rf/O, Fi7X0/Rf/T, Fi7X0/Rf/Ot
198
Wireless Modules
198
Control Module - FI700/RF/M1REL
198
Monitor Module - FI700/RF/M1IN
198
Wireless Sounders, Wireless Strobes
198
RF Remote Indicator
198
Modules
197
Conventional Zone Module - FI700/M1CZ
197
Input
197
Control Module with Supervision - Output
197
Control Module Without Supervision - Relay Output
197
Sounders, Strobes
197
Check of the Loop Lines
199
Contamination Detection and Maintenance Prognosis
200
Series FI700/FI750 Elements on the BC216 / BC600
200
Maintenance Prognosis
200
Series FI700/FI750 Elements on the BC216
200
Series FI700/FI750 Elements on the BC600
200
Detection of Detector Replacement
200
Advertisement
LST Series BC216 User Manual (73 pages)
Fire Detection Control Panel
Brand:
LST
| Category:
Control Panel
| Size: 0 MB
Table of Contents
Fire Detection Control Panel Series Bc216
1
Table of Contents
3
1 Introduction
7
Symbols and Type Fonts
8
Important Hints for the User and the Installer
8
What to Do in Case of a Fire Alarm
9
What to Do in Case of a Fault
9
Standards, CE-Labeling, Approvals
10
Warranty
11
Special Terms
11
2 Fire Detection Control Panel Series BC216
15
Typical Construction of a Fire Detection System with Control Panel BC216-1
15
Typical Construction of a Fire Detection System with Network Control Panel
16
Bcnet216
16
Features of the Fire Detection Control Panel Series BC216
17
Fire Detection Control Panel BC216-1 (Stand-Alone)
17
Fire Detection Control Panel Bcnet216 (Network Control Panel)
19
Peripheral Devices for the Fire Detection Control Panel Series BC216
19
Detectors
19
Acoustic and Optic Alarming Devices
20
Transmitting Devices
20
Actuations
21
Information Devices for the Fire Brigade
21
Information Systems
21
3 Displaying and Operating Elements
22
Info Field
23
Info'-Button
24
Menu Buttons
24
Numeric Keys
24
Element'-Button
24
Reset-Buttons
25
Light-Emitting Diodes Displays
25
TRANSM. DEVICE 1 - Field
25
ALARM. DEVICE 1 - Field
26
Optional LED-Display Field
27
Acoustic Signal
27
Protocol Printer
27
4 Basic Operation of the Fire Detection Control Panels Series BC216
29
Operating Authorization
29
Operations Using Single Buttons
31
Resetting the Fire Detection Control Panel
31
Silencing the Internal Buzzer / Display Test
31
Silencing the Primary Alarming Device
31
Alarm Delay Procedure of the Primary Transmitting Device
32
Operations Using the Menu
33
Menu-Quick-Operation
33
Exiting the Menu
34
Overview of the Display- and Operation Menus
34
Entering and Exiting Authorization Level 2
36
Entering and Exiting Authorization Level 3
36
Description of the Menu Points
37
Displaying Fire Alarms - Menu Point [Alarms]
37
Displaying Activated Actuations - Menu Point [Activated Actuations]
38
Displaying Technical Messages - Menu Point [Technical Messages]
38
Displaying Fault Messages - Menu Point [Faults]
38
Displaying Disablements - Menu Point [Disablements]
38
Displaying Test Conditions - Menu Point [Test Conditions]
39
Displaying and Operating Detector Zones - Menu Point [Zone:]
39
Operating Whole Detector Zones
39
Operating Single Elements of Detector Zones
40
Displaying and Operating Actuations - Menu Point [Actuations:]
41
Operating Actuations
41
Operating Single Elements of Actuations
42
Displaying and Operating Transmitting Devices - Menu Point [Transmit. Device:]
42
Displaying and Operating Alarming Devices - Menu Point [Alarming Device:]
43
Menu Point [Event Memory]
43
Menu Point [System]
44
Read-Out of the Event Counter - Submenu Point [Event Counter]
44
Testing the Optic and Acoustic Displays and the Buzzer - Submenu Point [Display Test]
44
Setting the Contrast - Submenu Point [LCD Contrast]
44
Correcting the Clock Time - Submenu Point [Clock Time Correction]
45
Setting the Clock Time - Submenu Point [Clock Time Setting]
45
Setting the Date - Submenu Point [Date Setting]
45
Switching to Summertime - Submenu Point [Winter/Summertime]
45
Switching to Standard Time - Submenu Point [Summer/Wintertime]
45
Displaying the Installed Componentries - Submenu Point [Componentries]
46
Printing - Submenu Point [Print-Out]
46
Repeating a Print-Out - Submenu Point [Repeat Print-Out]
47
Abort Measured Value Print-Out - Submenu Point [Stop Measurement Print-Out:]
47
Modifying the Numeric Code for the User - Submenu Point [Change User Code]
47
Changing the Numeric Code by the Installer - Submenu Point [Change Installer Code]
47
Menu Points [Authorization Code:], [Exit Authorization?]
47
Operating the Control Panel by Using the Fire Brigade Control Unit
48
5 Operating Conditions of Fire Detection Control Panels Series BC216
49
Normal Condition
50
Fire Alarm Condition
50
The First Operations on the Control Panel in Fire Alarm Condition
52
Resetting the Alarming Devices
54
Resetting an Alarm of a Detector Zone
54
Terminating the Fire Alarm Condition
54
Fire Alarm Condition - Special Case: Alarm in an Interdependence of Two Detectors
55
Activation Condition of Actuations
55
Activating an Actuation in a Two-Zone Dependency
56
Message Condition for Technical Messages
56
Resetting a Technical Message
57
Special Technical Messages
57
Fault-Message Condition
58
Disablement Condition
61
Test Condition
63
6 Ensuring the Efficacy of the System by the User
65
Periodic Function Tests
65
Testing of the Fire Detection Control Panel and the Power Supply Devices
65
Testing of Detectors
65
Testing the Alarming Devices
66
Testing the Fire Control Systems
66
Testing the Transmitting Devices
66
Other Tests
66
Reconditioning and Maintenance
67
Specifications of Control Panel Devices of Series BC216
67
7 Event Memory - Entries
68
8 Index
72
LST Series BC216 Brochure & Specs (5 pages)
Fire Detection Control Panel: 19“ Compact Version
Brand:
LST
| Category:
Control Panel
| Size: 0 MB
Advertisement
Advertisement
Related Products
LST BC06 Series
LST BC016 Series
LST BC600 Series
LST 130
LST AN9161202
LST HB216AE.SAM
LST ZN5002
LST Categories
Smoke Alarm
Security Sensors
Control Panel
Home Safety Product
Recording Equipment
More LST Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL