Sign In
Upload
Manuals
Brands
LST Manuals
Control Panel
BC600 Series
LST BC600 Series Manuals
Manuals and User Guides for LST BC600 Series. We have
3
LST BC600 Series manuals available for free PDF download: User Manual, Short User Manual
LST BC600 Series User Manual (200 pages)
Connection of detectors
Brand:
LST
| Category:
Control Panel
| Size: 9 MB
Table of Contents
Table of Contents
3
Introduction
11
General
11
Types of Symbols
11
Important Tips
11
Conventional Technology
12
General
12
Installation of Detectors
12
Schematic Circuit Diagram of a Detector Zone
12
Conditions of Zones
12
Cable Requirements
13
Connection of Manual Call Points
14
Connection of HFM/HM
14
Connection of HFM/HM with Individual Address Module NG58-1
15
Connection of HFM/HM with Address Module NG58-1 - Sum Indication
16
Connection of Manual Call Points Series HME
17
Connection of a C31
18
Connection of the Spring-Button Call Point Sm/5/52/02/0X
19
Arrangement of Wires in Detector Base FC600/BR, FC600/BRD, FC600/BREL
20
Automatic Detectors Series FC600
20
Connection
20
Connection of Automatic Detectors
20
Connection of Detectors with Remote Indicator PA58-3 and Address Module NG58-1
21
Connection with Diode Base FC600/BRD
21
Connection of Detectors with Relay Base FC600/BREL
22
Connection of Detectors with Remote Indicator PA58-3 and Address Module NG58-1
22
Arrangement of Wires in Detector Base FC600/BR, FC600/BRD, FC600/BREL
23
Automatic Detectors Series FC650
23
Connection
24
Connection with Diode Base FC600/BRD
24
Connection of Detectors with Remote Indicator PA58-3 and Address Module NG58-1
25
Connection of Detectors with Relay Base FC600/BREL
26
Connection of Duct Detectors FI700/DDH / FI750/DDH / FI750/DDH-2
27
Intrinsically Safe Detection Circuits
28
Optical Smoke Detector SLR-E-IS
29
Automatic Detectors Series ORBIS I.S
30
Thermal Detectors 6295 and 6296 with Safety Barrier ES58-2
31
Detectors Without Energy Storage - Contact Detectors
32
Manual Call Point with Zener Barrier Z978
33
Manual Call Point with Safety Barrier ES58-2
34
Thermal Max Detector with Zener Barrier Z978
35
Thermal Max Detector with Safety Barrier ES58-2
36
Intrinsically Safe Detectors for Hazardous Areas
37
Manual Call Point Ex Dc31
37
Manual Call Points for Hazardous Areas
37
Flame Detectors for Hazardous Areas
38
Flame Detectors Series 16000
39
Connection
40
Connection of Series Fi7X0/Rf Wireless Detectors
40
Notes
40
RF Interface Fi7X0/Rf/Cwe
40
Connection FI700/RF/WE - New Version - and FI720/RF/WE
41
Connection FI700/RF/WE - Old Version
41
RF Expander Fi7X0/Rf/We
41
Connection
42
Connection of Special Detectors
42
Flame Detector Series 16000
42
Settings
42
Flame Detector Series 800/24-VST-K-N
43
Thermal Detectors 6295, 6296, 6297 and 6298
44
Notes
44
Connection
44
Thermal Max Detector SWM-1KL
45
Notes
45
Connection
45
Thermal Max Detector SWM-1KL-140
46
Notes
46
Connection
46
Thermal Detector HT-27121-275
47
Notes
47
Connection
47
Heat Detector WMX5000FS
48
Connection
48
Notes
48
Linear Detectors
49
Linear Heat Detector Unit LWM-1
49
Linear Heat Detector Unit SCU800
50
Linear Heat Detector Unit SKM-03
51
Linear Heat Detector Unit ADW511A
52
Linear Heat Detector Unit ADW535-1
53
Beam Smoke Detector FR50/100
54
Beam Smoke Detector FR2000
55
Beam Smoke Detector FR3000
56
Beam Smoke Detector FR5000
57
Old Version
57
New Version
58
Beam Smoke Detector Thefirebeam Plus
59
Smoke Aspiration Systems
60
Smoke Aspiration System Titanus PRO·SENS - TP1/A
60
Connection of One Unit
60
Smoke Aspiration System Titanus PRO·SENS - TP1/A with 2 Channels
61
Smoke Aspiration System Titanus PRO SENSE - TP-4
62
Smoke Aspiration System Titanus TOP SENSE - TT-1
63
Smoke Aspiration System Titanus Super Sens - T-SS
64
Smoke Aspiration System Vesda VLF-250 / VLF-500
65
Smoke Aspiration System ASD532
66
Smoke Aspiration System ASD535 - 1 Channel
67
Smoke Aspiration System ASD535 - 2 Channels
68
Smoke Aspiration System ASD533
69
Smoke Aspiration System FAAST 8100E
70
Smoke Aspiration System FAAST LT - Model Fl01Xx - with 2 Channels
71
Connection of Door Magnets
72
Connection of Sounders and Strobes
73
EMA1224B4R D / EMA1224B4W D (Old Version)
73
EMA1224B4R-D / EMA1224B4W-D (New Version)
73
Sounder Ema1224B4X
73
Sounder DBS1224B4W D (Old Version)
74
Sounder DBS1224B4W-D (New Version)
74
Sounder Dbs1224B4X
74
Sounder MS1R
75
Sounder ROLP
76
Sounder ROLP/SV
77
Sounder SQUASHNI
78
Sounder SQUASHNI/SV
79
Sounder SYMPHONI HO
80
Sounder ASKARI - AC/SV/R/S - AC/SV/W1/S
81
Sounder-Strobe ROLP-SOLISTA
82
Sounder CWSO-XX-XX
83
Sounder-Strobe FLASHNI-SV
84
Sounder-Strobe FLASHNI-SV with Separate Actuation
85
Sounder-Strobe CWSS-XX-XX
86
Strobe SOLEX
87
Strobe SOLISTA LX
88
Strobe Ema24Rs5X
89
Strobe CWST-XX-XX
90
Coding of Address Module NG58-1
91
ADM Technology
92
General
92
Hints for Project Planning
92
Cable Requirements
93
Unshielded Cable
93
Shielded Cable
94
Address Programming of Loop Elements
95
AUTO-Addressing of Elements
95
AUTO-Setup - Automatic Addressing of All Loop Elements
95
[Initialize New Devices] - AUTO-Addressing of New Elements
98
Manual Addressing of Elements
99
Programming Units FI700/PU and FI750/PU
99
Switching on the Programming Unit FI700/PU or FI750/PU
100
Switching off the Programming Unit FI700/PU or FI750/PU
100
Connection of Loop Elements to the Programming Unit FI700/PU or FI750/PU
100
Expert Mode
102
Reading the Address
102
Setting the Address
102
Connection of Manual Call Points
103
Manual Call Points - Series FI700/MCP
103
Programming of the Address
103
Manual Call Points - HFM / HM
103
Manual Call Points Series HME
104
Connection of Intelligent Automatic Detectors
105
Automatic Detectors Series FI700
105
Connection of Detector Bases
105
Connection of Detector Bases FI700/B, FI700/BD, FI700/BREL
105
Programming of the Address of Automatic Detectors
105
Connection of Detector Bases FI700/B, FI700/BD, FI700/BREL with PA58-3
106
Automatic Detectors Series FI750
107
Connection of Detector Bases FI750/B
107
Programming the Address of Automatic Detectors
107
Connection of Duct Detector FI700/DDH
108
FI700/DDH with Series FI700
108
Connection of Duct Detector FI750/DDH
109
FI750/DDH with Series FI750
109
Automatic Detectors and Manual Call Points with the Conventional Zone Module FI700/M1CZ
110
Intrinsically Safe Detection Circuits for Hazardous Areas
110
Optical Smoke Detector SLR-E-IS
110
Automatic Detectors Series ORBIS I.S
111
Thermal Detectors 6295 and 6296
112
Intrinsically Safe Detectors for Hazardous Areas
113
Manual Call Point Ex Dc31
113
Flame Detectors - Series 16000
115
Contact Detectors with Monitor Modules and Zener Barrier Z978
117
Detectors Without Energy Storage - Contact Detectors
117
Connection with Monitor Module FI700/M1IN
118
Connection of Wireless Detectors Series Fi7X0/Rf
119
RF Interface Fi7X0/Rf/W2W
119
Notes
119
Connection
119
RF Expander Fi7X0/Rf/We
120
Connection FI700/RF/WE - Old Version
120
Connection FI700/RF/WE - New Version - and FI720/RF/WE
120
Connection of Conventional Detectors with a Conventional Zone Module FI700/M1CZ
121
Address Setting
121
Power Supply
121
Supply from the Fire Detection Control Panel or by an External Power Supply
122
Power Supply from the Loop
123
Manual Call Points Series C31
124
Detectors Series FC600 / FC650
125
Connection of Detectors Series FC600 / FC650 and External Power Supply of the Module
125
Flame Detector Series 16000
126
Note
126
Connection
126
Flame Detector 800/24-VST-K-N
127
Linear Heat Detector Unit Alarmline LWM-1
128
Linear Heat Detector Unit SKM-03
129
Linear Heat Detector Unit SCU800
130
Linear Heat Detector Unit ADW511A
131
Linear Heat Detector Unit ADW535
132
Beam Smoke Detector FR50/100
133
Beam Smoke Detector FR2000
134
Beam Smoke Detector FR3000
135
Beam Smoke Detector FR5000
136
Old Version
136
Beam Smoke Detector FR5000 (Issue-11)
137
Beam Smoke Detector Thefirebeam Plus
138
Beam Smoke Detectors 6500R and 6500RS
139
Smoke Aspiration System Titanus PRO·SENS - TP-1/A with One Detector Module
140
Smoke Aspiration System Titanus PRO·SENS - TP1/A with 2 Detector Modules
141
Smoke Aspiration System Titanus PRO SENS - TP-4 with 2 Detector Modules
142
Smoke Aspiration System Titanus TOP SENS - TT-1 with 2 Detector Modules
143
Smoke Aspiration System Titanus Super Sens - T-SS
144
Vlf-500
145
Smoke Aspiration System ASD532
146
Smoke Aspiration System ASD535 with One Channel
147
Smoke Aspiration System ASD535 with Two Channels
148
Smoke Aspiration System ASD533
149
Smoke Aspiration System FAAST LT - Model FL0122
150
Smoke Aspiration System FAAST 8100E
151
Thermal Detectors 6295, 6296, 6297 and 6298
152
Notes
152
Connection
152
Thermal Max Detector SWM-1KL
153
Thermal Max Detector SWM-1KL-140
154
Thermal Max Detector HT-27121-275
155
Address Setting
156
Connection of Contact Detectors with Monitor Modules
156
Connection of the Modules FI700/M1IN, FI700/MM1IN, FI700/MDR1IN
156
Function of the LED
156
Monitor Modules FI700/M1IN, FI700/MM1IN or FI700/MDR1IN
156
Connection
157
Monitor Module FI700/MMC1IN
157
Address Setting
158
Control Modules
158
Control Modules with Supervision
158
Function of the LED
158
Connection of Sirens with FI700/M1OUT, FI700/MM1OUT, FI700/MDR1OUT
159
Connection of Sirens with FI700/MMC1OUT
159
Connection of Door Magnets with FI700/M1OUT, FI700/MM1OUT, FI700/MDR1OUT
160
Connection of Door Magnets with FI700/MMC1OUT
160
Control Modules with Relay Output
161
Address Setting
161
Connection of Control Modules FI700/M1REL, FI700/MM1REL, FI700/MDR1REL
161
Function of the LED
161
Connection of Control Module FI700/MMC1REL
162
Combi Modules
163
Combi Modules with One (1) Supervised Input and One (1) Supervised Output
163
Address Setting
163
Function of the Leds
163
Connection of Combi Modules FI700/M1IN1OUT, FI700/MM1IN1OUT, FI700/MDR1IN1OUT
164
Combi Module with One (1) Supervised Input and One (1) Relay Output
165
Address Setting
165
Function of the Leds
165
Connection of Combi Modules FI700/M1IN1REL, FI700/MM1IN1REL, FI700/MDR1IN1REL
165
Connection of Combi Module FI700/MMC1IN1REL
166
Combi Module with Four (4) Supervised Inputs and Four (4) Relay Outputs
167
Address Setting
167
Connection of Combi Module FI700/M4IN4REL
167
Function of the Leds
167
Address Setting
168
Combi Module with Four (4) Supervised Inputs, Two (2) Supervised Outputs and Two (2) Relay Outputs
168
Connection of Combi Module FI700/M4IN2OUT2REL
168
Function of the Leds
168
Address Setting
169
Combi Module with Six (6) Supervised Inputs and Two (2) Relay Outputs
169
Connection of Combi Module FI700/M6IN2REL
169
Function of the Leds
169
Address Setting
170
Loop Sounders and Strobes
170
Notes
170
Connection
171
Sounder FI700/WM/MT/SOUR - FI700/WM/MT/SOUW
171
Sounder FI700/WM/SOUR - FI700/WM66/SOUR
171
Tone Setting
171
Connection
172
Tone Setting
172
Sounder FI700/FB/MT/SOUW
173
Connection
173
Tone Setting
173
Sounder-Strobe FI700/FBRI/MT/SOUW/STRR
174
Connection
174
Tone Setting
174
Sounder-Strobe FI700/WM/SOUR/STRR - FI700/WM66/SOUR/STRR
175
Connection
175
Tone Setting
175
Sounder(-Strobe) Cws/Soux / Cws/Soux/Strc with Module FI700/M/SST / FI750/M/SST
176
Connection
176
Tone Setting - Cws/Soux(/STRC) with Fi7X0/M/Sst
176
Sound Level - Cws/Soux(/STRC) with Fi7X0/M/Sst
177
Strobe FI700/WM/STRRR
178
Connection
178
Flash Frequency and Brightness
178
Sounder(-Strobe) FI700/WB/MT/SOUW - FI700/WB/MT/SOUW/STRC
179
Connection
179
Tone Setting
179
Sounder(-Strobe) FI700/WBRI/MT/SOUW - FI700/WBRI/MT/SSTWC
180
Connection
180
Tone Setting
180
Sound Level - FI700/WBRI/MT/SOUW and FI700/WBRI/MT/SSTWC
180
Sounder(-Strobe) FI750/WB/MT/SOUW - FI750/WB/MT/SOUW/STRC
181
Connection
181
Tone Setting
181
Sounder-Strobe FI750/WBRI/MT/SOUW - FI750/WBRI/MT/SSTWC
182
Connection
182
Tone Setting
182
Sound Level - FI750/WBRI/MT/SOUW
182
Sound Level - FI750/WBRI/MT/SSTWC
183
Connection
184
Tone Setting
185
Sound Level
185
Flash Energy
185
Sounder-Strobe FI750/WBRIS/SOUW - FI750/WBRIS/SSTWCR - FI750/WBRIS/SSTWCW
186
Connection
186
Tone Setting
186
Sound Level
187
Flash Energy
187
Remote Indicator
188
Address Setting
188
Example for the Wiring of Detector Circuits
189
System Cabling ADM Loop
189
Programming of Detectors, Modules and Signalling Devices
190
Parameterising Detectors on the BC216
190
Fi700/Fbri/Mt/Souw
191
Fi700/Pa
191
Parameterising Signalling Devices on the BC216
191
Parameterising Remote Indicators on the BC216
191
Parameterising Modules on the BC216
192
Parameterising Wireless Elements on the BC216
193
Settings of the Wireless Detectors that Are Made with the Parameterisation Software Wirelex
194
Analogue Values - Condition of Detectors/Modules
195
Function of the Leds
195
Automatic Detectors
195
Modules
195
Manual Call Points Series HFM/HME
195
Standard Detectors
196
Optical Smoke Detectors
196
Thermal Detector
196
Optical-Thermal Detectors
196
Manual Call Points
196
Remote Indicator
197
Wireless Elements
198
RF Interface - Fi7X0/Rf/W2W
198
Wireless Manual Call Point - FI700/RF/MCP
198
Automatic Wireless Detectors - Fi7X0/Rf/O, Fi7X0/Rf/T, Fi7X0/Rf/Ot
198
Wireless Modules
198
Control Module - FI700/RF/M1REL
198
Monitor Module - FI700/RF/M1IN
198
Wireless Sounders, Wireless Strobes
198
RF Remote Indicator
198
Modules
197
Conventional Zone Module - FI700/M1CZ
197
Input
197
Control Module with Supervision - Output
197
Control Module Without Supervision - Relay Output
197
Sounders, Strobes
197
Check of the Loop Lines
199
Contamination Detection and Maintenance Prognosis
200
Series FI700/FI750 Elements on the BC216 / BC600
200
Maintenance Prognosis
200
Series FI700/FI750 Elements on the BC216
200
Series FI700/FI750 Elements on the BC600
200
Detection of Detector Replacement
200
Advertisement
LST BC600 Series Short User Manual (55 pages)
Fire Detection Control Panel
Brand:
LST
| Category:
Control Panel
| Size: 2 MB
Table of Contents
Table of Contents
5
Introduction
9
General
9
Types of Symbols
9
Important Tips
10
Type Code
10
Components of the Fire Detection Control Panel Series BC600
12
Overview
12
Housings
12
Wall-Mount Cabinet for BC600-8Xxx or BC600-16Xxx
12
19-Inch Housing for BC600-Ce8Xxx
12
Central Processing Board ZTB600-1
12
Power Supplies NT602-1, NT604-1, NT608-1
12
Display and Operating Board ABB600-1
13
Function Modules
13
Loop Interface LIF601-1
13
Conventional Detector Interface GIF608-1
13
Fire Brigade Interface FWI600-1
13
Serial Interface SIF601-1
13
Backplane
13
Backplane BPL610-1
13
Backplane BPL608-1
14
LED Display Field LAF648-X
14
Stand-By Battery
14
Determining the Required Capacity of the Stand-By Battery
14
Control Panel Assembly, Installation of Optional Componentries
15
Location of Installation
15
Dimensions of the Control Panels
15
Dimensions of the Control Panel BC600-8Xxx
15
Dimensions of the Control Panel BC600-16Xxx
16
Dimensions of the Control Panel BC600-CE8
16
Installation of the Control Panel
17
Installation of the Control Panel in Wall-Mount Cabinet Design
17
Installing the Control Panel BC600-Ce8Xxx (19-Inch Version)
17
Installing Components in the Control Panels
17
General
17
Installation Options in the Control Panels
18
Installations in a Control Panel BC600-8Xxx
18
Installations in a Control Panel BC600-16Xxx
19
Installations in the Case BC600-Ce8Xxx
21
Installation of the Function Modules (LIF601-1 Etc.)
21
Installation and Labelling of the Expansion Fields (LAF648-X Etc.)
22
Installation of the Stand-By Batteries
22
Internal Bus System and System Supply
23
General
23
System Bus
23
UI Bus
23
System Supply
23
Addressing of the Components
24
Backplane BPL610-1
24
Logic Addresses of the Function Modules in the Wall-Mount Cabinet with Backplane BPL610-1
24
Backplane BPL608-1
24
Logic Addresses of the Function Modules if a Backplane BPL610-1 Is Expanded
25
With a BPL608-1
25
Addressing of the Power Units
25
Addressing of the UI Bus Members (Componentries in the Door or Front)
25
Bus Cabling, System Supply Cabling
25
Bus Cabling in the Standard Wall-Mount Cabinet (Schematic Circuit Diagram)
25
Connection
28
General Instructions
28
Power Supply
28
General Information
28
Power Supply - Fuse Protection
28
Using more than One Power Unit in a Control Panel
28
Maximum Battery Capacity According to en 54-4
29
Connection of the Mains Power, the Stand-By Battery and the 24VDC Power Consuming Devices
29
View of the Power Supply NT602-1
30
Connections and Schematic Circuit Diagram of the Power Supply NT602-1
30
View of the Power Supply NT604-1
31
Connections and Schematic Circuit Diagram of the Power Supply NT604-1
31
View of the Power Supply NT608-1
32
Connections and Schematic Circuit Diagram of the Power Supply NT608-1
33
Connection to the Central Processing Board ZTB600-1
33
Position of the Connection and Operating Elements
34
Settings of the DIP Switches S1
34
Connecting the PARSOFT PC Via the USB1 Interface
34
Connecting Devices to the USB2 Interface (USB Host)
34
Connection of the Relay Outputs
34
Connection of the ZTB Inputs
35
Connection of the Siren Outputs
36
Connection of INFO Bus Devices
36
Connection of the OC Outputs
37
Connection of the Function Modules - General
38
Position of the Connection and Operating Elements on the Function Modules
38
Connecting the Loop Line to the Loop Interface LIF601-1
38
Connection of Detectors to the Conventional Detector Interface GIF608-1
39
Connection to the Fire Brigade Interface FWI600-1
40
Connection to the Inputs of the FWI600-1
41
Connection to the Relay Output of the FWI600-1
41
Connection to the Open-Collector Outputs of the FWI600-1
41
Connection to the Line-Monitored Output of the FWI600-1
41
Connection to the Serial Interface SIF601-1
41
Connection to the Network Interface NIF600-1
42
Net600 with Ring Cabling
43
Connection of the Display and Operating Board ABB600-1
44
Connection of the Componentries of the Expansion Fields
44
LED Display Field LAF648-X
44
LED Button Field LTF616-X
44
Commissioning
45
Connection of the Supply Voltages
45
Parameterisation and Function Tests
46
Recalculation of the Mains Failure Bridging Time and the Maximum Current of the System
46
Labelling of the Fire Detection Control Panel
46
CE-Labelling
46
Type Label, Additional Label
46
Fault Situation
48
Conditions of the Componentry Status Display (LED)
48
Emergency Operation
49
System Fault
49
Redundant Alarm
49
Specifications
50
General Data
50
Maximum Values of Every Control Panel or Sectional Control Panel of a Bcnet600
50
Fire Detection Control Panel BC600-8Xxx
50
Fire Detection Control Panel BC600-16Xxx
50
Fire Detection Control Panel BC600-Ce8Xxx
50
Power Supply NT602-1
50
Power Supply NT604-1
51
Power Supply NT608-1
51
Central Processing Board ZTB600-1
52
Relay Outputs
52
Inputs
52
Alarming Devices (Siren Outputs 1 and 2)
52
INFO Bus
52
OC Outputs
52
Loop Interface LIF601-1
52
Conventional Detector Interface GIF608-1
53
Fire Brigade Interface FWI600-1
53
Serial Interface SIF601-1
53
Network Interface NIF600-1
54
Network Cable
54
Display and Operating Board ABB600-1
54
LED Display Field LAF648-X
54
LED Button Field LTF616-X
54
Backplane BPL610-1
54
Backplane BPL608-1
54
Additional Information for the CE-Labelling
55
LST BC600 Series Short User Manual (48 pages)
Fire Detection Control Panel
Brand:
LST
| Category:
Control Panel
| Size: 1 MB
Table of Contents
Important Note
3
Table of Contents
5
Introduction
9
Types of Symbols
10
Important Tips for the User and the Installer
10
Ambient Conditions
10
Warranty
10
Short Form of the most Important Operations on the Control Panel
11
Operating Authorization, General Operation
11
Fire Alarm
11
Fault
12
Technical Message
12
Disabling / Testing / Enabling System Parts
12
Structure of a Fire Detection System
13
Typical Construction of a Fire Detection System with Control Panel Series BC600
13
Features of the Control Panel Series BC600
13
Basic Features of All Control Panels Series BC600
13
Displaying and Operating Elements
15
Standard Displays and Operating Elements
15
Summary Displays
15
Display
16
Function Keys
16
Status Displays
17
Transmitting Device
17
LED Displays in the 'Transmitting Device' Field
17
Alarm Delay/Explore' Key
18
Actuations
18
Special Functions
18
Alarming Device
18
Navigation Keys
19
Enter Key
19
Off/On or 0/1 Key
19
Key (Help Key)
19
Element Key
19
Numeric Keypad
19
Silence Buzzer Key
19
Reset Key
19
Operation of the Control Panel by the User
20
Authorization for Operation
20
Authorization Level 1
20
Authorization Level 2
20
Authorization Level 3
20
Operations Using Single Keys
20
Resetting the Control Panel
20
Silencing the Internal Buzzer / Display Test
21
Silencing the Standard Alarming Device
21
Alarm Delay Circuit of the Primary Transmitting Device
21
Menu Structure
22
Operation Menus
23
Operation Menus - General
23
Displaying and Operating Detector Zones - [Zones]
23
Indications of the Detector Zones/Elements
24
Indications of a Device with Elements in Different Switching States
24
Selecting an Individual Device
24
Carrying out an Operation on a Detector Zone/Element
24
Displaying and Operating Actuations - [Actuations]
25
Indications of the Actuations/Elements
25
Carrying out an Operation on an Actuation/Element
25
Displaying and Operating Transmitting Devices - [Transm. Devices]
26
Indications of the Transmitting Devices
26
Carrying out an Operation
26
Displaying and Operating Alarming Devices - [Alarming Devices]
27
Indications of the Alarming Devices
27
Carrying out an Operation
27
Event Lists for the Indication of the Current Events
27
System Menus
28
[Event Memory]
28
Status]
29
[Status of the Componentries]
29
[Counter Readings]
30
[Firmware Update]
30
[Configuration Update]
30
[Settings]
30
Display Test
30
[Date/Time]
30
[Clock Accuracy]
31
[LCD Contrast]
31
[Key Tones]
31
Authorization]
31
[Change User Code]
31
[Change Installer Code]
31
[Language]
31
Operating Conditions
33
Normal Condition
33
Fire Alarm Condition
34
Indication of the Fire Alarm Condition on the Control Panel
34
Individual Displays
34
Display
34
Further Indications in the Event of a Fire Alarm
34
The First Operations on the Control Panel in Fire Alarm Condition
35
Silencing the Alarming Devices
36
Terminating a Detector Zone Alarm
36
Terminating the Fire Alarm Condition
36
Fire Alarm Condition - Special Case: Alarm in an Interdependence of Two Detectors, Pre-Alarm
36
Fire Alarm Condition in the Event of a System Fault: Redundant Alarm
36
Activation of Outputs
36
Indication of the Activation of Outputs
37
Individual Displays
37
Display
37
Activating an Output Function in a Multiple Combination
37
Resetting Activated Outputs
37
Technical Messages
38
Indication of the Message Condition of Technical Messages
38
Individual Displays
38
Display
38
Terminating a Technical Message
38
Fault Message Condition
39
Indication of Faults
39
Individual Displays
39
Display
39
Further Indications in the Event of a Fault
39
Faults of the Power Supply
40
System Fault - Emergency Operation
40
Resetting Fault Messages
41
Disablement Condition
41
Indication of Disablements
41
Individual Displays
41
Display
41
Test Condition
42
Individual Displays
42
Display
42
Confirmations
43
Ensuring the Efficacy of the System by the User
44
Periodic Function Tests
44
Testing of the Control Panel and the Power Supply Devices
44
Testing the Detectors
44
Testing the Alarming Devices
44
Testing the Fire Prevention Devices
45
Testing the Transmitting Devices
45
Other Tests
45
Servicing and Maintenance
45
Appendix
46
Meaning of the Condition Symbols Shown on the Display
46
Condition Symbols for Detector Zones and Elements (Detectors)
46
Condition Symbols for Actuations, Alarming Devices and Transmitting Devices
47
Index
48
Advertisement
Advertisement
Related Products
LST Series BC216
LST BC06 Series
LST BC016 Series
LST 130
LST AN9161202
LST HB216AE.SAM
LST ZN5002
LST Categories
Smoke Alarm
Security Sensors
Control Panel
Home Safety Product
Recording Equipment
More LST Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL