Sign In
Upload
Manuals
Brands
LS Industrial Systems Manuals
Inverter
iG5A Series
LS Industrial Systems iG5A Series Drive Manuals
Manuals and User Guides for LS Industrial Systems iG5A Series Drive. We have
2
LS Industrial Systems iG5A Series Drive manuals available for free PDF download: Manual, Troubleshooting Manual
LS Industrial Systems iG5A Series Manual (100 pages)
Brand:
LS Industrial Systems
| Category:
Control Unit
| Size: 2 MB
Table of Contents
Table of Contents
2
제 1 장 소 개
5
Canopen이란
5
Canopen 옵션 보드를 사용하면
5
제품 구성품
5
제 2 장 Canopen 통신 옵션
6
Canopen 통신 모듈 일반 규격
6
옵션 외관
7
Canopen 통신 단자대 규격
8
제어 단자대 규격 (Control I/O)
9
Canopen 통신 모듈 장착 방법 및 순서
10
설치 시 주의 사항
11
Baud Rate에 따른 최대 통신거리
11
제 3 장 옵션 상태 진단 및 Led에 대한 정의
12
Led에 대한 정의
12
Led 상태에 따른 옵션 상태 진단
12
제 4 장 Canopen의 Data 통신 규칙
16
Canopen의 통신 규칙
16
Can-ID
16
Sdo 통신
17
Pdo 통신
17
Nmt(Network Management) State Machine
18
NMT State Initialization
19
NMT State Pre-Operational
19
NMT State Operational
19
NMT State Stopped
20
Nmt 상태에 따른 통신 가능 프레임
20
Error Control Protocols
21
Protocol Node Guarding
21
Protocol Heartbeat
22
Canopen EDS File
23
제 5 장 Detailed Specification of Communication Profile Specific Objects
24
Device Type
24
Error Register
24
Pre-Defined Error Field
24
COB-ID SYNC Message
25
Manufacturer Device Nme
26
Manufacturer Hardware Version
26
Manufacturer Software Version
26
Guard Time
26
Life Time Factor
27
Store Parameters
27
Cob-ID Emcy
28
Producer Heartbeat Time
28
제 6 장 Profile
29
Cia 402 Drive and Motion Control Device Profile
29
Finite State Automation
29
Cia 402 SDO
31
Ig5A용 Sdo
40
Pdo
41
Rpdo
41
Rpdo Mapping
42
Tpdo
43
Tpdo Mapping
44
제 7 장 인버터 파라미터
45
관련 파라미터 리스트
45
기본 Field Bus 파라미터 설명
47
C 3 Fbus ID
47
C 5 Fbus LED
47
C99 Comm Update
47
C 4 Fbus Baudrate
47
주기 통신용 파라미터 설정
48
C22 Canopen Profile
48
C31~C34 Para Status
48
Lost Command 파라미터 설정
48
I62 Lost CMD Mode
49
I63 Lost CMD Time
49
Chapter1. Introduction
57
What Is Canopen
57
What Are the Benefits of Using the Canopen Option Board
57
Components
57
Current
57
Chapter 2. Canopen Communication Option
58
General Specification of Canopen Communication Module
58
Layout of Canopen Communication Module
59
Canopen Communication Terminal Specification
60
Control Terminal Specification
61
Voltage
61
Installation of Canopen Communication Module
62
Instruction for Installation
63
Maximum Communication Range According to Baud Rate
63
Chapter 3. Diagnosis of the Option Statuses and LED Definition
64
Definition of the LED Signal
64
Diagnosis of Option by LED Signal
64
Chapter 4. Data Communication Protocol of the Canopen
68
Communication Protocol of the Canopen
68
Can-ID
68
SDO Communication
69
PDO Communication
69
NMT (Network Management) State Machine
70
NMT State Initialization
71
NMT State Pre-Operational
71
NMT State Operational
72
NMT State Stopped
72
The Frames Enabling Communication by NMT Status
72
Error Control Protocols
72
Protocol Node Guarding
73
Protocol Heartbeat
73
Canopen EDS File
74
Chapter 5. Detailed Specification of Communication Profile Specific Objects
75
Device Type
75
Error Register
75
Pre-Defined Error Field
75
Device Profile Specific
75
COB-ID SYNC Message
76
Manufacturer Device Name
77
Manufacturer Hardware Version
77
Manufacturer Software Version
77
Guard Time
77
Life Time Factor
78
Store Parameters
78
Cob-ID Emcy
78
Producer Heartbeat Time
79
Chapter 6. Profile
80
Cia 402 Drive and Motion Control Device Profile
80
Finite State Automation
80
Cia 402 SDO
82
Enable Ramp) 1
83
SDO for IG5A
90
Pdo
91
Rpdo
91
RPDO Mapping
92
Tpdo
93
TPDO Mapping
94
Chapter 7. Inverter Parameter
95
Related Parameter List
95
Description on the Basic Field Bus Parameters
97
C 3 Fbus ID
97
C 5 Fbus LED
97
C99 Comm Update
97
C 4 Fbus Baudrate
97
C22 Canopen Profile
98
Parameter Setting for the Periodic Communication
98
C31~C34 Para Status
98
C51~C54 Para Control
98
Parameter Setting for the Lost Command
98
I62 Lost CMD Mode
98
I63 Lost CMD Time
99
Advertisement
LS Industrial Systems iG5A Series Troubleshooting Manual (45 pages)
AC Variable Speed Drive, 0.4~22kW 200V/400V
Brand:
LS Industrial Systems
| Category:
Inverter
| Size: 2 MB
Table of Contents
Table of Contents
3
Introduction
4
INTRODUCTION Manual Composition
4
Product Identification
5
Association Manual
5
Safety Information
6
Revision Record
8
1 Basic Checklist
9
Before You Think It Is Failure
9
Basic Operations
11
Operation Keys
12
Parameter Change
13
Carrier Frequency Change
13
Initializing All Parameters
14
Read and Write Parameters
15
Fault Trip Monitoring
16
2 Troubleshooting
19
Trips and Warnings
19
2.1.1 Fault/Warning List
20
Fault/Warning List
20
Category LCD Display
21
Details Page
21
Troubleshooting Fault Trips
22
Over Current Trip
22
ARM Short Current Fault Trip
23
Ground Fault Trip
23
Inverter Overload Fault Trip
24
Over Heat Fault Trip
24
Output Open-Phase Fault Trip
25
Over Voltage Trip
25
Cooling Fan Fault
25
Electronic Thermal
26
Error
27
External Fault a Contact Input
27
External Fault B Contact Input
27
Parameter Save Error
28
Communication Error
28
Keypad Error
28
NTC Open
28
Troubleshooting Other Faults
29
3 Maintenance
35
Regular Inspection Lists
36
Daily Inspections
36
Annual Inspections
37
Bi-Annual Inspections
38
Checking the Input/Output Modules
39
Replacement of the Cooling Fan
43
Storage and Disposal
45
Storage
45
Disposal
45
Advertisement
Related Products
LS Industrial Systems iS7 RAPIEnet
LS Industrial Systems LSLV-S100
LS Industrial Systems S100
LS Industrial Systems STARVERT iG5A
LS Industrial Systems SV iC5 Series
LS Industrial Systems SV-iS7 Series
LS Industrial Systems SV-iV5 Series
LS Industrial Systems SV001iE5-1
LS Industrial Systems SV001iE5-2
LS Industrial Systems SV002iE5-1
LS Industrial Systems Categories
Controller
Inverter
Control Unit
DC Drives
Circuit breakers
More LS Industrial Systems Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL