3
Littelfuse Startco SE-330 Series manuals available for free PDF download: Manual
Littelfuse Startco SE-330 Series Manual (36 pages)
Neutral-Grounding-Resistor Monitor
Brand:
Littelfuse Startco
| Category:
Measuring Instruments
| Size: 1.39 MB
Table of Contents
Table of Contents
2
General
3
Modern Resistance-Grounded Systems
3
SE-330 NGR Monitoring
3
Operation
4
Settings
4
GF Trip Time
4
GF Trip Level
4
Ntrip Level
4
Pulse-Period Adjustment
5
Configuration Settings
5
Configuration Switches
5
Typical Values for Tripping Systems
5
Ground-Fault Trip Levels for Selected Ct's
5
Relay K1 Function (S1)
6
Trip-Relay Mode and Trip Memory Mode(S2)
6
Ground-Fault-Trip Latch (S3)
6
Resistor-Fault-Trip Latch (S4)
6
Sensing-Resistor Selection (S5)
6
Frequency (S6)
6
Spare (S7)
6
Upgrade Enable (S8)
6
Calibration
6
Pulsing Operation
6
Trip Indication and Reset
7
Remote Operation
7
Relay K1 LED
7
Unit Healthy Output
7
Diagnostic LED
7
Analog Output
8
Installation
8
Se-330
8
Analog-Output Connections
8
SE-330 Connection Diagram
9
SE-330 Outline and Panel-Mounting Details
10
SE-330 Outline and Surface-Mounting Details
11
SE-IP65CVR-G Weatherproof Cover Outline
12
Sensing Resistor
14
SE-IP65CVR-G Weatherproof Cover Installation . 11 8 ER-600VC Sensing Resistor
14
SE-MRE-600 Moisture-Resistant Enclosure Outline 13 10 SE-MRE-600 with Installed ER-600VC
16
ER-5KV Sensing Resistor
17
ER-5WP Sensing Resistor
18
ER-15KV Sensing Resistor
19
ER-25KV Sensing Resistor
20
ER-35KV Sensing Resistor
21
Ground-Fault CT
22
EFCT-1 Ground-Fault Current Sensor
23
SE-CS30-70 Ground-Fault Current Sensor
24
EFCT-26 and SE-CS30-26 Ground-Fault Current Sensors
25
Isolated Ground Connection
26
RK-332 Remote Indication and Reset
26
Simplified Isolated-Ground Connection
26
Pulsing Connection
27
Communications
27
Local Communications Port
27
Local Data Acquisition
27
Local Communications Commands
27
Firmware Upgrade
27
Network Communications
27
Simplified Pulsing Connection
27
RS-232 DB-9 Terminals
27
Troubleshooting
28
Technical Specifications
29
Se-330
29
Sensing Resistors
30
Current Sensors
31
Ordering Information
31
Warranty
32
Test Procedures
33
Resistor-Fault Tests
33
Calibration and Open Test
33
Voltage Test
33
Sensing-Resistor Test
33
Analog-Output Test
33
Ground-Fault Performance Test
34
Ground-Fault-Test Circuits
35
Ground-Fault-Test Record
35
Advertisement
Littelfuse Startco SE-330 Series Manual (24 pages)
IEC 61850 INTERFACE
Brand:
Littelfuse Startco
| Category:
Recording Equipment
| Size: 1.19 MB
Table of Contents
Table of Contents
3
Section
5
General
5
Configuration Software
5
Network Configuration
5
Ethernet Ports
5
IP Settings
5
SNTP Settings
5
IEC 61850 Clients
5
Default IP Settings
5
SE-MON330 Communications Settings
6
Top View of SE-330 (SE-330-X6-XX) with Dual RJ-45 Ethernet Network Communications
6
Top View of SE-330 (SE-330-X7-XX) with Single Fiber SC and Single RJ-45 Ethernet Network Communications
7
Top View of SE-330 (SE-330-X8-XX) with Dual Fiber SC Ethernet Network Communications
7
IEC 61850 Configuration
8
Server Configuration
8
SE-MON330 IEC 61850 Server Configuration Tab
8
Server Configuration Parameters
8
SE-MON330 IEC 61850 Report Control Block (RCB) Configuration Tab
9
Report Control Blocks
10
RCB Report Conditions
10
RCB Optional Fields
10
Data Sets
11
SE-MON330 IEC 61850 Data Sets Tab
11
SE-MON330 IEC 61850 Data Set Properties Window
12
GOOSE Settings
13
GOOSE Control Blocks
13
GOOSE Network Inputs
13
SE-MON330 IEC 61850 GOOSE Tab
14
GOOSE Network Input Status Values
15
MMS Data Model
16
Device Information LLN0
16
Report Control Blocks
16
LLN0 - Logical Node Data
16
Default Datasets
17
GOOSE Control Blocks
17
Physical Device LPHD
17
LPHD - Logical Node Data
17
Metering UIRMMXU1
18
Ground Fault GFPTOC1
19
Resistor Fault RFPTOV1
20
Command CMDGGIO0
21
Event Record RECGGIO2
22
Specifications
23
Appendix A SE-330 Series (New Revision)
24
IEC 61850 Interface Revision History
24
Littelfuse Startco SE-330 Series Manual (10 pages)
SE-330 series ETHERNET/IP INTERFACE
Brand:
Littelfuse Startco
| Category:
Computer Hardware
| Size: 0.9 MB
Table of Contents
Table of Contents
3
Section
5
General
5
SE-330 Ethernet/Ip Interface
5
SE-330 Network Settings
5
RSLOGIX5000 Setup
5
LED Indication
5
Top View of SE-330 (SE-330-X3-XX) with Dual RJ-45 Ethernet Network Communications
6
Top View of SE-330 (SE-330-X4-XX) with Single Fiber SC and Single RJ-45 Ethernet Network Communications
6
Top View of SE-330 (SE-330-X5-XX) with Dual Fiber SC Ethernet Network Communications
7
Ethernet/Ip Objects
8
Identity Object
8
Assembly Object
9
Input Assembly
9
Output Assembly
9
Specifications
9
Appendix A SE-330 Series (New Revision) Ethernet/Ip Interface Revision History
10
Advertisement
Advertisement
Related Products
Littelfuse Startco SE-330AU
Littelfuse Startco SE-330HV
Littelfuse Startco SE-330-X3 Series
Littelfuse Startco SE-330-X4 Series
Littelfuse Startco SE-330-X5 Series
Littelfuse Startco SE-325
Littelfuse Startco SE-135
Littelfuse Startco SE-601
Littelfuse Startco SE-107
Littelfuse Startco SE-400-02
Littelfuse Startco Categories
Monitor
Measuring Instruments
Recording Equipment
Computer Hardware
Outdoor Cart
More Littelfuse Startco Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL